Merge branch 'irq-core-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git...
[pandora-kernel.git] / drivers / hwmon / pmbus / Kconfig
1 #
2 # PMBus chip drivers configuration
3 #
4
5 menuconfig PMBUS
6         tristate "PMBus support"
7         depends on I2C && EXPERIMENTAL
8         default n
9         help
10           Say yes here if you want to enable PMBus support.
11
12           This driver can also be built as a module. If so, the module will
13           be called pmbus_core.
14
15 if PMBUS
16
17 config SENSORS_PMBUS
18         tristate "Generic PMBus devices"
19         default y
20         help
21           If you say yes here you get hardware monitoring support for generic
22           PMBus devices, including but not limited to ADP4000, BMR450, BMR451,
23           BMR453, BMR454, NCP4200, and NCP4208.
24
25           This driver can also be built as a module. If so, the module will
26           be called pmbus.
27
28 config SENSORS_ADM1275
29         tristate "Analog Devices ADM1275 and compatibles"
30         default n
31         help
32           If you say yes here you get hardware monitoring support for Analog
33           Devices ADM1275 and ADM1276 Hot-Swap Controller and Digital Power
34           Monitor.
35
36           This driver can also be built as a module. If so, the module will
37           be called adm1275.
38
39 config SENSORS_LM25066
40         tristate "National Semiconductor LM25066 and compatibles"
41         default n
42         help
43           If you say yes here you get hardware monitoring support for National
44           Semiconductor LM25066, LM5064, and LM5066.
45
46           This driver can also be built as a module. If so, the module will
47           be called lm25066.
48
49 config SENSORS_LTC2978
50         tristate "Linear Technologies LTC2978 and LTC3880"
51         default n
52         help
53           If you say yes here you get hardware monitoring support for Linear
54           Technology LTC2978 and LTC3880.
55
56           This driver can also be built as a module. If so, the module will
57           be called ltc2978.
58
59 config SENSORS_MAX16064
60         tristate "Maxim MAX16064"
61         default n
62         help
63           If you say yes here you get hardware monitoring support for Maxim
64           MAX16064.
65
66           This driver can also be built as a module. If so, the module will
67           be called max16064.
68
69 config SENSORS_MAX34440
70         tristate "Maxim MAX34440/MAX34441"
71         default n
72         help
73           If you say yes here you get hardware monitoring support for Maxim
74           MAX34440 and MAX34441.
75
76           This driver can also be built as a module. If so, the module will
77           be called max34440.
78
79 config SENSORS_MAX8688
80         tristate "Maxim MAX8688"
81         default n
82         help
83           If you say yes here you get hardware monitoring support for Maxim
84           MAX8688.
85
86           This driver can also be built as a module. If so, the module will
87           be called max8688.
88
89 config SENSORS_UCD9000
90         tristate "TI UCD90120, UCD90124, UCD9090, UCD90910"
91         default n
92         help
93           If you say yes here you get hardware monitoring support for TI
94           UCD90120, UCD90124, UCD9090, UCD90910 Sequencer and System Health
95           Controllers.
96
97           This driver can also be built as a module. If so, the module will
98           be called ucd9000.
99
100 config SENSORS_UCD9200
101         tristate "TI UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, UCD9248"
102         default n
103         help
104           If you say yes here you get hardware monitoring support for TI
105           UCD9220, UCD9222, UCD9224, UCD9240, UCD9244, UCD9246, and UCD9248
106           Digital PWM System Controllers.
107
108           This driver can also be built as a module. If so, the module will
109           be called ucd9200.
110
111 config SENSORS_ZL6100
112         tristate "Intersil ZL6100 and compatibles"
113         default n
114         help
115           If you say yes here you get hardware monitoring support for Intersil
116           ZL2004, ZL2006, ZL2008, ZL2105, ZL2106, ZL6100, and ZL6105 Digital
117           DC/DC Controllers.
118
119           This driver can also be built as a module. If so, the module will
120           be called zl6100.