OMAP3: PM: Set/clear T2 bit for Smartreflex on TWL
authorThara Gopinath <thara@ti.com>
Tue, 15 Feb 2011 07:58:58 +0000 (13:28 +0530)
committerKevin Hilman <khilman@ti.com>
Thu, 10 Mar 2011 00:15:50 +0000 (16:15 -0800)
Voltage control on TWL can be done using VMODE/I2C1/I2C_SR.
Since almost all platforms use I2C_SR on omap3, omap3_twl_init by
default expects that OMAP's I2C_SR is plugged in to TWL's I2C
and calls omap3_twl_set_sr_bit. On platforms where I2C_SR is not connected,
the board files are expected to call omap3_twl_set_sr_bit(false) to
ensure that I2C_SR path is not set for voltage control and prevent
the default behavior of omap3_twl_init.

Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Thara Gopinath <thara@ti.com>
Signed-off-by: Shweta Gulati <shweta.gulati@ti.com>
Cc: linux-arm-kernel@lists.infradead.org
Signed-off-by: Kevin Hilman <khilman@ti.com>
arch/arm/mach-omap2/omap_twl.c
arch/arm/mach-omap2/pm.h

index 00e1d2b..b341c36 100644 (file)
 
 static bool is_offset_valid;
 static u8 smps_offset;
+/*
+ * Flag to ensure Smartreflex bit in TWL
+ * being cleared in board file is not overwritten.
+ */
+static bool __initdata twl_sr_enable_autoinit;
 
+#define TWL4030_DCDC_GLOBAL_CFG        0x06
 #define REG_SMPS_OFFSET         0xE0
+#define SMARTREFLEX_ENABLE     BIT(3)
 
 static unsigned long twl4030_vsel_to_uv(const u8 vsel)
 {
@@ -269,6 +276,18 @@ int __init omap3_twl_init(void)
                omap3_core_volt_info.vp_vddmax = OMAP3630_VP2_VLIMITTO_VDDMAX;
        }
 
+       /*
+        * The smartreflex bit on twl4030 specifies if the setting of voltage
+        * is done over the I2C_SR path. Since this setting is independent of
+        * the actual usage of smartreflex AVS module, we enable TWL SR bit
+        * by default irrespective of whether smartreflex AVS module is enabled
+        * on the OMAP side or not. This is because without this bit enabled,
+        * the voltage scaling through vp forceupdate/bypass mechanism of
+        * voltage scaling will not function on TWL over I2C_SR.
+        */
+       if (!twl_sr_enable_autoinit)
+               omap3_twl_set_sr_bit(true);
+
        voltdm = omap_voltage_domain_lookup("mpu");
        omap_voltage_register_pmic(voltdm, &omap3_mpu_volt_info);
 
@@ -277,3 +296,44 @@ int __init omap3_twl_init(void)
 
        return 0;
 }
+
+/**
+ * omap3_twl_set_sr_bit() - Set/Clear SR bit on TWL
+ * @enable: enable SR mode in twl or not
+ *
+ * If 'enable' is true, enables Smartreflex bit on TWL 4030 to make sure
+ * voltage scaling through OMAP SR works. Else, the smartreflex bit
+ * on twl4030 is cleared as there are platforms which use OMAP3 and T2 but
+ * use Synchronized Scaling Hardware Strategy (ENABLE_VMODE=1) and Direct
+ * Strategy Software Scaling Mode (ENABLE_VMODE=0), for setting the voltages,
+ * in those scenarios this bit is to be cleared (enable = false).
+ *
+ * Returns 0 on sucess, error is returned if I2C read/write fails.
+ */
+int __init omap3_twl_set_sr_bit(bool enable)
+{
+       u8 temp;
+       int ret;
+       if (twl_sr_enable_autoinit)
+               pr_warning("%s: unexpected multiple calls\n", __func__);
+
+       ret = twl_i2c_read_u8(TWL4030_MODULE_PM_RECEIVER, &temp,
+                                       TWL4030_DCDC_GLOBAL_CFG);
+       if (ret)
+               goto err;
+
+       if (enable)
+               temp |= SMARTREFLEX_ENABLE;
+       else
+               temp &= ~SMARTREFLEX_ENABLE;
+
+       ret = twl_i2c_write_u8(TWL4030_MODULE_PM_RECEIVER, temp,
+                               TWL4030_DCDC_GLOBAL_CFG);
+       if (!ret) {
+               twl_sr_enable_autoinit = true;
+               return 0;
+       }
+err:
+       pr_err("%s: Error access to TWL4030 (%d)\n", __func__, ret);
+       return ret;
+}
index 1c1b0ab..f4a5f71 100644 (file)
@@ -127,6 +127,7 @@ static inline void omap_enable_smartreflex_on_init(void) {}
 #ifdef CONFIG_TWL4030_CORE
 extern int omap3_twl_init(void);
 extern int omap4_twl_init(void);
+extern int omap3_twl_set_sr_bit(bool enable);
 #else
 static inline int omap3_twl_init(void)
 {