USB: pl2303: use divisors for unsupported baud rates
authorLauri Hintsala <lauri.hintsala@bluegiga.com>
Wed, 13 Aug 2014 12:02:53 +0000 (15:02 +0300)
committerJohan Hovold <johan@kernel.org>
Mon, 1 Sep 2014 10:04:17 +0000 (12:04 +0200)
Use direct method for supported baud rates, otherwise use divisors.
Limit baud rate to 12 Mbaud with HX type.

This change has been tested to work with PL-2303HX at 115200, 500000,
1000000, 2000000, 2500000, 3000000 and 4000000 baud rates.

Signed-off-by: Lauri Hintsala <lauri.hintsala@bluegiga.com>
Signed-off-by: Johan Hovold <johan@kernel.org>
drivers/usb/serial/pl2303.c

index e9bad92..0f872e6 100644 (file)
@@ -162,6 +162,9 @@ static const struct pl2303_type_data pl2303_type_data[TYPE_COUNT] = {
                .max_baud_rate =        1228800,
                .quirks =               PL2303_QUIRK_LEGACY,
        },
+       [TYPE_HX] = {
+               .max_baud_rate =        12000000,
+       },
 };
 
 static int pl2303_vendor_read(struct usb_serial *serial, u16 value,
@@ -395,16 +398,14 @@ static void pl2303_encode_baud_rate(struct tty_struct *tty,
        if (spriv->type->max_baud_rate)
                baud = min_t(speed_t, baud, spriv->type->max_baud_rate);
        /*
-        * Set baud rate to nearest supported value.
-        *
-        * NOTE: Baud rate 500k can only be set using divisors.
+        * Use direct method for supported baud rates, otherwise use divisors.
         */
        baud_sup = pl2303_get_supported_baud_rate(baud);
 
-       if (baud == 500000)
-               baud = pl2303_encode_baud_rate_divisor(buf, baud);
+       if (baud == baud_sup)
+               baud = pl2303_encode_baud_rate_direct(buf, baud);
        else
-               baud = pl2303_encode_baud_rate_direct(buf, baud_sup);
+               baud = pl2303_encode_baud_rate_divisor(buf, baud);
 
        /* Save resulting baud rate */
        tty_encode_baud_rate(tty, baud, baud);