Merge branch 'for-linus' of git://opensource.wolfsonmicro.com/regulator
[pandora-kernel.git] / Documentation / power / regulator / machine.txt
index b42419b..ce63af0 100644 (file)
@@ -16,7 +16,7 @@ initialisation code by creating a struct regulator_consumer_supply for
 each regulator.
 
 struct regulator_consumer_supply {
-       struct device *dev;     /* consumer */
+       const char *dev_name;   /* consumer dev_name() */
        const char *supply;     /* consumer supply - e.g. "vcc" */
 };
 
@@ -24,13 +24,13 @@ e.g. for the machine above
 
 static struct regulator_consumer_supply regulator1_consumers[] = {
 {
-       .dev    = &platform_consumerB_device.dev,
-       .supply = "Vcc",
+       .dev_name       = "dev_name(consumer B)",
+       .supply         = "Vcc",
 },};
 
 static struct regulator_consumer_supply regulator2_consumers[] = {
 {
-       .dev    = &platform_consumerA_device.dev,
+       .dev    = "dev_name(consumer A"),
        .supply = "Vcc",
 },};
 
@@ -43,6 +43,7 @@ to their supply regulator :-
 
 static struct regulator_init_data regulator1_data = {
        .constraints = {
+               .name = "Regulator-1",
                .min_uV = 3300000,
                .max_uV = 3300000,
                .valid_modes_mask = REGULATOR_MODE_NORMAL,
@@ -51,13 +52,19 @@ static struct regulator_init_data regulator1_data = {
        .consumer_supplies = regulator1_consumers,
 };
 
+The name field should be set to something that is usefully descriptive
+for the board for configuration of supplies for other regulators and
+for use in logging and other diagnostic output.  Normally the name
+used for the supply rail in the schematic is a good choice.  If no
+name is provided then the subsystem will choose one.
+
 Regulator-1 supplies power to Regulator-2. This relationship must be registered
 with the core so that Regulator-1 is also enabled when Consumer A enables its
 supply (Regulator-2). The supply regulator is set by the supply_regulator
-field below:-
+field below and co:-
 
 static struct regulator_init_data regulator2_data = {
-       .supply_regulator = "regulator_name",
+       .supply_regulator = "Regulator-1",
        .constraints = {
                .min_uV = 1800000,
                .max_uV = 2000000,