Merge branch 'linux-next' of git://git.infradead.org/ubifs-2.6
[pandora-kernel.git] / Documentation / ABI / testing / sysfs-class-regulator
index 873ef1f..e091fa8 100644 (file)
@@ -4,8 +4,8 @@ KernelVersion:  2.6.26
 Contact:       Liam Girdwood <lrg@slimlogic.co.uk>
 Description:
                Some regulator directories will contain a field called
-               state. This reports the regulator enable status, for
-               regulators which can report that value.
+               state. This reports the regulator enable control, for
+               regulators which can report that input value.
 
                This will be one of the following strings:
 
@@ -14,16 +14,54 @@ Description:
                'unknown'
 
                'enabled' means the regulator output is ON and is supplying
-               power to the system.
+               power to the system (assuming no error prevents it).
 
                'disabled' means the regulator output is OFF and is not
-               supplying power to the system..
+               supplying power to the system (unless some non-Linux
+               control has enabled it).
 
                'unknown' means software cannot determine the state, or
                the reported state is invalid.
 
                NOTE: this field can be used in conjunction with microvolts
-               and microamps to determine regulator output levels.
+               or microamps to determine configured regulator output levels.
+
+
+What:          /sys/class/regulator/.../status
+Description:
+               Some regulator directories will contain a field called
+               "status". This reports the current regulator status, for
+               regulators which can report that output value.
+
+               This will be one of the following strings:
+
+                       off
+                       on
+                       error
+                       fast
+                       normal
+                       idle
+                       standby
+
+               "off" means the regulator is not supplying power to the
+               system.
+
+               "on" means the regulator is supplying power to the system,
+               and the regulator can't report a detailed operation mode.
+
+               "error" indicates an out-of-regulation status such as being
+               disabled due to thermal shutdown, or voltage being unstable
+               because of problems with the input power supply.
+
+               "fast", "normal", "idle", and "standby" are all detailed
+               regulator operation modes (described elsewhere).  They
+               imply "on", but provide more detail.
+
+               Note that regulator status is a function of many inputs,
+               not limited to control inputs from Linux.  For example,
+               the actual load presented may trigger "error" status; or
+               a regulator may be enabled by another user, even though
+               Linux did not enable it.
 
 
 What:          /sys/class/regulator/.../type
@@ -58,7 +96,7 @@ Description:
                Some regulator directories will contain a field called
                microvolts. This holds the regulator output voltage setting
                measured in microvolts (i.e. E-6 Volts), for regulators
-               which can report that voltage.
+               which can report the control input for voltage.
 
                NOTE: This value should not be used to determine the regulator
                output voltage level as this value is the same regardless of
@@ -73,7 +111,7 @@ Description:
                Some regulator directories will contain a field called
                microamps. This holds the regulator output current limit
                setting measured in microamps (i.e. E-6 Amps), for regulators
-               which can report that current.
+               which can report the control input for a current limit.
 
                NOTE: This value should not be used to determine the regulator
                output current level as this value is the same regardless of
@@ -87,7 +125,7 @@ Contact:     Liam Girdwood <lrg@slimlogic.co.uk>
 Description:
                Some regulator directories will contain a field called
                opmode. This holds the current regulator operating mode,
-               for regulators which can report it.
+               for regulators which can report that control input value.
 
                The opmode value can be one of the following strings:
 
@@ -101,7 +139,8 @@ Description:
 
                NOTE: This value should not be used to determine the regulator
                output operating mode as this value is the same regardless of
-               whether the regulator is enabled or disabled.
+               whether the regulator is enabled or disabled.  A "status"
+               attribute may be available to determine the actual mode.
 
 
 What:          /sys/class/regulator/.../min_microvolts