-The ADM1027 and ADT7463 have a 10-bit ADC and can therefore measure
-temperatures with 0.25 degC resolution. They also provide an offset to the
-temperature readings that is automatically applied during measurement.
-This offset can be used to zero out any errors due to traces and placement.
-The documentation says that the offset is in 0.25 degC steps, but in
-initial testing of the ADM1027 it was 1.00 degC steps. Analog Devices has
-confirmed this "bug". The ADT7463 is reported to work as described in the
-documentation. The current lm85 driver does not show the offset register.
+The ADM1027, ADT7463 and ADT7468 have a 10-bit ADC and can therefore
+measure temperatures with 0.25 degC resolution. They also provide an offset
+to the temperature readings that is automatically applied during
+measurement. This offset can be used to zero out any errors due to traces
+and placement. The documentation says that the offset is in 0.25 degC
+steps, but in initial testing of the ADM1027 it was 1.00 degC steps. Analog
+Devices has confirmed this "bug". The ADT7463 is reported to work as
+described in the documentation. The current lm85 driver does not show the
+offset register.
+
+The ADT7468 has a high-frequency PWM mode, where all PWM outputs are
+driven by a 22.5 kHz clock. This is a global mode, not per-PWM output,
+which means that setting any PWM frequency above 11.3 kHz will switch
+all 3 PWM outputs to a 22.5 kHz frequency. Conversely, setting any PWM
+frequency below 11.3 kHz will switch all 3 PWM outputs to a frequency
+between 10 and 100 Hz, which can then be tuned separately.