Merge tag 'devicetree-for-linus' of git://git.secretlab.ca/git/linux-2.6
[pandora-kernel.git] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config SCSI_MOD
4        tristate
5        default y if SCSI=n || SCSI=y
6        default m if SCSI=m
7
8 config RAID_ATTRS
9         tristate "RAID Transport Class"
10         default n
11         depends on BLOCK
12         depends on SCSI_MOD
13         ---help---
14           Provides RAID
15
16 config SCSI
17         tristate "SCSI device support"
18         depends on BLOCK
19         select SCSI_DMA if HAS_DMA
20         ---help---
21           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
22           any other SCSI device under Linux, say Y and make sure that you know
23           the name of your SCSI host adapter (the card inside your computer
24           that "speaks" the SCSI protocol, also called SCSI controller),
25           because you will be asked for it.
26
27           You also need to say Y here if you have a device which speaks
28           the SCSI protocol.  Examples of this include the parallel port
29           version of the IOMEGA ZIP drive, USB storage devices, Fibre
30           Channel, and FireWire storage.
31
32           To compile this driver as a module, choose M here and read
33           <file:Documentation/scsi/scsi.txt>.
34           The module will be called scsi_mod.
35
36           However, do not compile this as a module if your root file system
37           (the one containing the directory /) is located on a SCSI device.
38
39 config SCSI_DMA
40         bool
41         default n
42
43 config SCSI_TGT
44         tristate "SCSI target support"
45         depends on SCSI && EXPERIMENTAL
46         ---help---
47           If you want to use SCSI target mode drivers enable this option.
48           If you choose M, the module will be called scsi_tgt.
49
50 config SCSI_NETLINK
51         bool
52         default n
53         select NET
54
55 config SCSI_PROC_FS
56         bool "legacy /proc/scsi/ support"
57         depends on SCSI && PROC_FS
58         default y
59         ---help---
60           This option enables support for the various files in
61           /proc/scsi.  In Linux 2.6 this has been superseded by
62           files in sysfs but many legacy applications rely on this.
63
64           If unsure say Y.
65
66 comment "SCSI support type (disk, tape, CD-ROM)"
67         depends on SCSI
68
69 config BLK_DEV_SD
70         tristate "SCSI disk support"
71         depends on SCSI
72         select CRC_T10DIF if BLK_DEV_INTEGRITY
73         ---help---
74           If you want to use SCSI hard disks, Fibre Channel disks,
75           Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
76           USB storage or the SCSI or parallel port version of
77           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
78           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
79           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
80           CD-ROMs.
81
82           To compile this driver as a module, choose M here and read
83           <file:Documentation/scsi/scsi.txt>.
84           The module will be called sd_mod.
85
86           Do not compile this driver as a module if your root file system
87           (the one containing the directory /) is located on a SCSI disk.
88           In this case, do not compile the driver for your SCSI host adapter
89           (below) as a module either.
90
91 config CHR_DEV_ST
92         tristate "SCSI tape support"
93         depends on SCSI
94         ---help---
95           If you want to use a SCSI tape drive under Linux, say Y and read the
96           SCSI-HOWTO, available from
97           <http://www.tldp.org/docs.html#howto>, and
98           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
99           for SCSI CD-ROMs.
100
101           To compile this driver as a module, choose M here and read
102           <file:Documentation/scsi/scsi.txt>. The module will be called st.
103
104 config CHR_DEV_OSST
105         tristate "SCSI OnStream SC-x0 tape support"
106         depends on SCSI
107         ---help---
108           The OnStream SC-x0 SCSI tape drives cannot be driven by the
109           standard st driver, but instead need this special osst driver and
110           use the  /dev/osstX char device nodes (major 206).  Via usb-storage,
111           you may be able to drive the USB-x0 and DI-x0 drives as well.
112           Note that there is also a second generation of OnStream
113           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
114           tapes (QIC-157) and can be driven by the standard driver st.
115           For more information, you may have a look at the SCSI-HOWTO
116           <http://www.tldp.org/docs.html#howto>  and
117           <file:Documentation/scsi/osst.txt>  in the kernel source.
118           More info on the OnStream driver may be found on
119           <http://sourceforge.net/projects/osst/>
120           Please also have a look at the standard st docu, as most of it
121           applies to osst as well.
122
123           To compile this driver as a module, choose M here and read
124           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
125
126 config BLK_DEV_SR
127         tristate "SCSI CDROM support"
128         depends on SCSI
129         ---help---
130           If you want to use a CD or DVD drive attached to your computer
131           by SCSI, FireWire, USB or ATAPI, say Y and read the SCSI-HOWTO
132           and the CDROM-HOWTO at <http://www.tldp.org/docs.html#howto>.
133
134           Make sure to say Y or M to "ISO 9660 CD-ROM file system support".
135
136           To compile this driver as a module, choose M here and read
137           <file:Documentation/scsi/scsi.txt>.
138           The module will be called sr_mod.
139
140 config BLK_DEV_SR_VENDOR
141         bool "Enable vendor-specific extensions (for SCSI CDROM)"
142         depends on BLK_DEV_SR
143         help
144           This enables the usage of vendor specific SCSI commands. This is
145           required to support multisession CDs with old NEC/TOSHIBA cdrom
146           drives (and HP Writers). If you have such a drive and get the first
147           session only, try saying Y here; everybody else says N.
148
149 config CHR_DEV_SG
150         tristate "SCSI generic support"
151         depends on SCSI
152         ---help---
153           If you want to use SCSI scanners, synthesizers or CD-writers or just
154           about anything having "SCSI" in its name other than hard disks,
155           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
156           directly, so you need some additional software which knows how to
157           talk to these devices using the SCSI protocol:
158
159           For scanners, look at SANE (<http://www.sane-project.org/>). For CD
160           writer software look at Cdrtools
161           (<http://cdrecord.berlios.de/private/cdrecord.html>)
162           and for burning a "disk at once": CDRDAO
163           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
164           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
165           For other devices, it's possible that you'll have to write the
166           driver software yourself. Please read the file
167           <file:Documentation/scsi/scsi-generic.txt> for more information.
168
169           To compile this driver as a module, choose M here and read
170           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
171
172           If unsure, say N.
173
174 config CHR_DEV_SCH
175         tristate "SCSI media changer support"
176         depends on SCSI
177         ---help---
178           This is a driver for SCSI media changers.  Most common devices are
179           tape libraries and MOD/CDROM jukeboxes.  *Real* jukeboxes, you
180           don't need this for those tiny 6-slot cdrom changers.  Media
181           changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
182           If you have such hardware and want to use it with linux, say Y
183           here.  Check <file:Documentation/scsi/scsi-changer.txt> for details.
184         
185           If you want to compile this as a module ( = code which can be
186           inserted in and removed from the running kernel whenever you want),
187           say M here and read <file:Documentation/kbuild/modules.txt> and
188           <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
189           If unsure, say N.
190
191 config SCSI_ENCLOSURE
192         tristate "SCSI Enclosure Support"
193         depends on SCSI && ENCLOSURE_SERVICES
194         help
195           Enclosures are devices sitting on or in SCSI backplanes that
196           manage devices.  If you have a disk cage, the chances are that
197           it has an enclosure device.  Selecting this option will just allow
198           certain enclosure conditions to be reported and is not required.
199
200 config SCSI_MULTI_LUN
201         bool "Probe all LUNs on each SCSI device"
202         depends on SCSI
203         help
204           Some devices support more than one LUN (Logical Unit Number) in order
205           to allow access to several media, e.g. CD jukebox, USB card reader,
206           mobile phone in mass storage mode. This option forces the kernel to
207           probe for all LUNs by default. This setting can be overriden by
208           max_luns boot/module parameter. Note that this option does not affect
209           devices conforming to SCSI-3 or higher as they can explicitely report
210           their number of LUNs. It is safe to say Y here unless you have one of
211           those rare devices which reacts in an unexpected way when probed for
212           multiple LUNs.
213
214 config SCSI_CONSTANTS
215         bool "Verbose SCSI error reporting (kernel size +=12K)"
216         depends on SCSI
217         help
218           The error messages regarding your SCSI hardware will be easier to
219           understand if you say Y here; it will enlarge your kernel by about
220           12 KB. If in doubt, say Y.
221
222 config SCSI_LOGGING
223         bool "SCSI logging facility"
224         depends on SCSI
225         ---help---
226           This turns on a logging facility that can be used to debug a number
227           of SCSI related problems.
228
229           If you say Y here, no logging output will appear by default, but you
230           can enable logging by saying Y to "/proc file system support" and
231           "Sysctl support" below and executing the command
232
233           echo <bitmask> > /proc/sys/dev/scsi/logging_level
234
235           where <bitmask> is a four byte value representing the logging type
236           and logging level for each type of logging selected.
237
238           There are a number of logging types and you can find them in the
239           source at <file:drivers/scsi/scsi_logging.h>. The logging levels
240           are also described in that file and they determine the verbosity of
241           the logging for each logging type.
242
243           If you say N here, it may be harder to track down some types of SCSI
244           problems. If you say Y here your kernel will be somewhat larger, but
245           there should be no noticeable performance impact as long as you have
246           logging turned off.
247
248 config SCSI_SCAN_ASYNC
249         bool "Asynchronous SCSI scanning"
250         depends on SCSI
251         help
252           The SCSI subsystem can probe for devices while the rest of the
253           system continues booting, and even probe devices on different
254           busses in parallel, leading to a significant speed-up.
255
256           If you have built SCSI as modules, enabling this option can
257           be a problem as the devices may not have been found by the
258           time your system expects them to have been.  You can load the
259           scsi_wait_scan module to ensure that all scans have completed.
260           If you build your SCSI drivers into the kernel, then everything
261           will work fine if you say Y here.
262
263           You can override this choice by specifying "scsi_mod.scan=sync"
264           or async on the kernel's command line.
265
266 config SCSI_WAIT_SCAN
267         tristate  # No prompt here, this is an invisible symbol.
268         default m
269         depends on SCSI
270         depends on MODULES
271 # scsi_wait_scan is a loadable module which waits until all the async scans are
272 # complete.  The idea is to use it in initrd/ initramfs scripts.  You modprobe
273 # it after all the modprobes of the root SCSI drivers and it will wait until
274 # they have all finished scanning their buses before allowing the boot to
275 # proceed.  (This method is not applicable if targets boot independently in
276 # parallel with the initiator, or with transports with non-deterministic target
277 # discovery schemes, or if a transport driver does not support scsi_wait_scan.)
278 #
279 # This symbol is not exposed as a prompt because little is to be gained by
280 # disabling it, whereas people who accidentally switch it off may wonder why
281 # their mkinitrd gets into trouble.
282
283 menu "SCSI Transports"
284         depends on SCSI
285
286 config SCSI_SPI_ATTRS
287         tristate "Parallel SCSI (SPI) Transport Attributes"
288         depends on SCSI
289         help
290           If you wish to export transport-specific information about
291           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
292
293 config SCSI_FC_ATTRS
294         tristate "FiberChannel Transport Attributes"
295         depends on SCSI
296         select SCSI_NETLINK
297         help
298           If you wish to export transport-specific information about
299           each attached FiberChannel device to sysfs, say Y.
300           Otherwise, say N.
301
302 config SCSI_FC_TGT_ATTRS
303         bool "SCSI target support for FiberChannel Transport Attributes"
304         depends on SCSI_FC_ATTRS
305         depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
306         help
307                 If you want to use SCSI target mode drivers enable this option.
308
309 config SCSI_ISCSI_ATTRS
310         tristate "iSCSI Transport Attributes"
311         depends on SCSI && NET
312         select BLK_DEV_BSGLIB
313         help
314           If you wish to export transport-specific information about
315           each attached iSCSI device to sysfs, say Y.
316           Otherwise, say N.
317
318 config SCSI_SAS_ATTRS
319         tristate "SAS Transport Attributes"
320         depends on SCSI
321         select BLK_DEV_BSG
322         help
323           If you wish to export transport-specific information about
324           each attached SAS device to sysfs, say Y.
325
326 source "drivers/scsi/libsas/Kconfig"
327
328 config SCSI_SRP_ATTRS
329         tristate "SRP Transport Attributes"
330         depends on SCSI
331         help
332           If you wish to export transport-specific information about
333           each attached SRP device to sysfs, say Y.
334
335 config SCSI_SRP_TGT_ATTRS
336         bool "SCSI target support for SRP Transport Attributes"
337         depends on SCSI_SRP_ATTRS
338         depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
339         help
340                 If you want to use SCSI target mode drivers enable this option.
341
342 endmenu
343
344 menuconfig SCSI_LOWLEVEL
345         bool "SCSI low-level drivers"
346         depends on SCSI!=n
347         default y
348
349 if SCSI_LOWLEVEL && SCSI
350
351 config ISCSI_TCP
352         tristate "iSCSI Initiator over TCP/IP"
353         depends on SCSI && INET
354         select CRYPTO
355         select CRYPTO_MD5
356         select CRYPTO_CRC32C
357         select SCSI_ISCSI_ATTRS
358         help
359          The iSCSI Driver provides a host with the ability to access storage
360          through an IP network. The driver uses the iSCSI protocol to transport
361          SCSI requests and responses over a TCP/IP network between the host
362          (the "initiator") and "targets".  Architecturally, the iSCSI driver
363          combines with the host's TCP/IP stack, network drivers, and Network
364          Interface Card (NIC) to provide the same functions as a SCSI or a
365          Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
366
367          To compile this driver as a module, choose M here: the
368          module will be called iscsi_tcp.
369
370          The userspace component needed to initialize the driver, documentation,
371          and sample configuration files can be found here:
372
373          http://open-iscsi.org
374
375 config ISCSI_BOOT_SYSFS
376         tristate "iSCSI Boot Sysfs Interface"
377         default n
378         help
379           This option enables support for exposing iSCSI boot information
380           via sysfs to userspace. If you wish to export this information,
381           say Y. Otherwise, say N.
382
383 source "drivers/scsi/cxgbi/Kconfig"
384 source "drivers/scsi/bnx2i/Kconfig"
385 source "drivers/scsi/bnx2fc/Kconfig"
386 source "drivers/scsi/be2iscsi/Kconfig"
387
388 config SGIWD93_SCSI
389         tristate "SGI WD93C93 SCSI Driver"
390         depends on SGI_HAS_WD93 && SCSI
391         help
392           If you have a Western Digital WD93 SCSI controller on
393           an SGI MIPS system, say Y.  Otherwise, say N.
394
395 config BLK_DEV_3W_XXXX_RAID
396         tristate "3ware 5/6/7/8xxx ATA-RAID support"
397         depends on PCI && SCSI
398         help
399           3ware is the only hardware ATA-Raid product in Linux to date.
400           This card is 2,4, or 8 channel master mode support only.
401           SCSI support required!!!
402
403           <http://www.3ware.com/>
404
405           Please read the comments at the top of
406           <file:drivers/scsi/3w-xxxx.c>.
407
408 config SCSI_HPSA
409         tristate "HP Smart Array SCSI driver"
410         depends on PCI && SCSI
411         help
412           This driver supports HP Smart Array Controllers (circa 2009).
413           It is a SCSI alternative to the cciss driver, which is a block
414           driver.  Anyone wishing to use HP Smart Array controllers who
415           would prefer the devices be presented to linux as SCSI devices,
416           rather than as generic block devices should say Y here.
417
418 config SCSI_3W_9XXX
419         tristate "3ware 9xxx SATA-RAID support"
420         depends on PCI && SCSI
421         help
422           This driver supports the 9000 series 3ware SATA-RAID cards.
423
424           <http://www.amcc.com>
425
426           Please read the comments at the top of
427           <file:drivers/scsi/3w-9xxx.c>.
428
429 config SCSI_3W_SAS
430         tristate "3ware 97xx SAS/SATA-RAID support"
431         depends on PCI && SCSI
432         help
433           This driver supports the LSI 3ware 9750 6Gb/s SAS/SATA-RAID cards.
434
435           <http://www.lsi.com>
436
437           Please read the comments at the top of
438           <file:drivers/scsi/3w-sas.c>.
439
440 config SCSI_7000FASST
441         tristate "7000FASST SCSI support"
442         depends on ISA && SCSI && ISA_DMA_API
443         select CHECK_SIGNATURE
444         help
445           This driver supports the Western Digital 7000 SCSI host adapter
446           family.  Some information is in the source:
447           <file:drivers/scsi/wd7000.c>.
448
449           To compile this driver as a module, choose M here: the
450           module will be called wd7000.
451
452 config SCSI_ACARD
453         tristate "ACARD SCSI support"
454         depends on PCI && SCSI
455         help
456           This driver supports the ACARD SCSI host adapter.
457           Support Chip <ATP870 ATP876 ATP880 ATP885>
458           To compile this driver as a module, choose M here: the
459           module will be called atp870u.
460
461 config SCSI_AHA152X
462         tristate "Adaptec AHA152X/2825 support"
463         depends on ISA && SCSI && !64BIT
464         select SCSI_SPI_ATTRS
465         select CHECK_SIGNATURE
466         ---help---
467           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
468           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
469           must be manually specified in this case.
470
471           It is explained in section 3.3 of the SCSI-HOWTO, available from
472           <http://www.tldp.org/docs.html#howto>. You might also want to
473           read the file <file:Documentation/scsi/aha152x.txt>.
474
475           To compile this driver as a module, choose M here: the
476           module will be called aha152x.
477
478 config SCSI_AHA1542
479         tristate "Adaptec AHA1542 support"
480         depends on ISA && SCSI && ISA_DMA_API
481         ---help---
482           This is support for a SCSI host adapter.  It is explained in section
483           3.4 of the SCSI-HOWTO, available from
484           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
485           purchased by Adaptec, and some former Trantor products are being
486           sold under the Adaptec name.  If it doesn't work out of the box, you
487           may have to change some settings in <file:drivers/scsi/aha1542.h>.
488
489           To compile this driver as a module, choose M here: the
490           module will be called aha1542.
491
492 config SCSI_AHA1740
493         tristate "Adaptec AHA1740 support"
494         depends on EISA && SCSI
495         ---help---
496           This is support for a SCSI host adapter.  It is explained in section
497           3.5 of the SCSI-HOWTO, available from
498           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
499           of the box, you may have to change some settings in
500           <file:drivers/scsi/aha1740.h>.
501
502           To compile this driver as a module, choose M here: the
503           module will be called aha1740.
504
505 config SCSI_AACRAID
506         tristate "Adaptec AACRAID support"
507         depends on SCSI && PCI
508         help
509           This driver supports a variety of Dell, HP, Adaptec, IBM and
510           ICP storage products. For a list of supported products, refer
511           to <file:Documentation/scsi/aacraid.txt>.
512
513           To compile this driver as a module, choose M here: the module
514           will be called aacraid.
515
516
517 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
518
519 config SCSI_AIC7XXX_OLD
520         tristate "Adaptec AIC7xxx support (old driver)"
521         depends on (ISA || EISA || PCI ) && SCSI
522         help
523           WARNING This driver is an older aic7xxx driver and is no longer
524           under active development.  Adaptec, Inc. is writing a new driver to
525           take the place of this one, and it is recommended that whenever
526           possible, people should use the new Adaptec written driver instead
527           of this one.  This driver will eventually be phased out entirely.
528
529           This is support for the various aic7xxx based Adaptec SCSI
530           controllers. These include the 274x EISA cards; 284x VLB cards;
531           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
532           motherboard based SCSI controllers from Adaptec. It does not support
533           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
534           support them. It does not support the 2920 cards from Adaptec that
535           use the Future Domain SCSI controller chip. For those cards, you
536           need the "Future Domain 16xx SCSI support" driver.
537
538           In general, if the controller is based on an Adaptec SCSI controller
539           chip from the aic777x series or the aic78xx series, this driver
540           should work. The only exception is the 7810 which is specifically
541           not supported (that's the RAID controller chip on the AAA-13x
542           cards).
543
544           Note that the AHA2920 SCSI host adapter is *not* supported by this
545           driver; choose "Future Domain 16xx SCSI support" instead if you have
546           one of those.
547
548           Information on the configuration options for this controller can be
549           found by checking the help file for each of the available
550           configuration options. You should read
551           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
552           contacting the maintainer with any questions.  The SCSI-HOWTO,
553           available from <http://www.tldp.org/docs.html#howto>, can also
554           be of great help.
555
556           To compile this driver as a module, choose M here: the
557           module will be called aic7xxx_old.
558
559 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
560 source "drivers/scsi/aic94xx/Kconfig"
561 source "drivers/scsi/mvsas/Kconfig"
562
563 config SCSI_MVUMI
564         tristate "Marvell UMI driver"
565         depends on SCSI && PCI
566         help
567           Module for Marvell Universal Message Interface(UMI) driver
568
569           To compile this driver as a module, choose M here: the
570           module will be called mvumi.
571
572 config SCSI_DPT_I2O
573         tristate "Adaptec I2O RAID support "
574         depends on SCSI && PCI && VIRT_TO_BUS
575         help
576           This driver supports all of Adaptec's I2O based RAID controllers as 
577           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
578           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
579
580           To compile this driver as a module, choose M here: the
581           module will be called dpt_i2o.
582
583 config SCSI_ADVANSYS
584         tristate "AdvanSys SCSI support"
585         depends on SCSI && VIRT_TO_BUS
586         depends on ISA || EISA || PCI
587         help
588           This is a driver for all SCSI host adapters manufactured by
589           AdvanSys. It is documented in the kernel source in
590           <file:drivers/scsi/advansys.c>.
591
592           To compile this driver as a module, choose M here: the
593           module will be called advansys.
594
595 config SCSI_IN2000
596         tristate "Always IN2000 SCSI support"
597         depends on ISA && SCSI
598         help
599           This is support for an ISA bus SCSI host adapter.  You'll find more
600           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
601           out of the box, you may have to change the jumpers for IRQ or
602           address selection.
603
604           To compile this driver as a module, choose M here: the
605           module will be called in2000.
606
607 config SCSI_ARCMSR
608         tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
609         depends on PCI && SCSI
610         help
611           This driver supports all of ARECA's SATA/SAS RAID controller cards.
612           This is an ARECA-maintained driver by Erich Chen.
613           If you have any problems, please mail to: <erich@areca.com.tw>.
614           Areca supports Linux RAID config tools.
615           Please link <http://www.areca.com.tw>
616
617           To compile this driver as a module, choose M here: the
618           module will be called arcmsr (modprobe arcmsr).
619
620 source "drivers/scsi/megaraid/Kconfig.megaraid"
621 source "drivers/scsi/mpt2sas/Kconfig"
622
623 config SCSI_HPTIOP
624         tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
625         depends on SCSI && PCI
626         help
627           This option enables support for HighPoint RocketRAID 3xxx/4xxx
628           controllers.
629
630           To compile this driver as a module, choose M here; the module
631           will be called hptiop. If unsure, say N.
632
633 config SCSI_BUSLOGIC
634         tristate "BusLogic SCSI support"
635         depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
636         ---help---
637           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
638           Adapters. Consult the SCSI-HOWTO, available from
639           <http://www.tldp.org/docs.html#howto>, and the files
640           <file:Documentation/scsi/BusLogic.txt> and
641           <file:Documentation/scsi/FlashPoint.txt> for more information.
642           Note that support for FlashPoint is only available for 32-bit
643           x86 configurations.
644
645           To compile this driver as a module, choose M here: the
646           module will be called BusLogic.
647
648 config SCSI_FLASHPOINT
649         bool "FlashPoint support"
650         depends on SCSI_BUSLOGIC && PCI && X86_32
651         help
652           This option allows you to add FlashPoint support to the
653           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
654           substantial, so users of MultiMaster Host Adapters may not
655           wish to include it.
656
657 config VMWARE_PVSCSI
658         tristate "VMware PVSCSI driver support"
659         depends on PCI && SCSI && X86
660         help
661           This driver supports VMware's para virtualized SCSI HBA.
662           To compile this driver as a module, choose M here: the
663           module will be called vmw_pvscsi.
664
665 config HYPERV_STORAGE
666         tristate "Microsoft Hyper-V virtual storage driver"
667         depends on SCSI && HYPERV
668         default HYPERV
669         help
670           Select this option to enable the Hyper-V virtual storage driver.
671
672 config LIBFC
673         tristate "LibFC module"
674         select SCSI_FC_ATTRS
675         select CRC32
676         ---help---
677           Fibre Channel library module
678
679 config LIBFCOE
680         tristate "LibFCoE module"
681         select LIBFC
682         ---help---
683           Library for Fibre Channel over Ethernet module
684
685 config FCOE
686         tristate "FCoE module"
687         depends on PCI
688         select LIBFCOE
689         ---help---
690           Fibre Channel over Ethernet module
691
692 config FCOE_FNIC
693         tristate "Cisco FNIC Driver"
694         depends on PCI && X86
695         select LIBFCOE
696         help
697           This is support for the Cisco PCI-Express FCoE HBA.
698
699           To compile this driver as a module, choose M here and read
700           <file:Documentation/scsi/scsi.txt>.
701           The module will be called fnic.
702
703 config SCSI_DMX3191D
704         tristate "DMX3191D SCSI support"
705         depends on PCI && SCSI
706         select SCSI_SPI_ATTRS
707         help
708           This is support for Domex DMX3191D SCSI Host Adapters.
709
710           To compile this driver as a module, choose M here: the
711           module will be called dmx3191d.
712
713 config SCSI_DTC3280
714         tristate "DTC3180/3280 SCSI support"
715         depends on ISA && SCSI
716         select SCSI_SPI_ATTRS
717         select CHECK_SIGNATURE
718         help
719           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
720           the SCSI-HOWTO, available from
721           <http://www.tldp.org/docs.html#howto>, and the file
722           <file:Documentation/scsi/dtc3x80.txt>.
723
724           To compile this driver as a module, choose M here: the
725           module will be called dtc.
726
727 config SCSI_EATA
728         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
729         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
730         ---help---
731           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
732           ISA and all EISA I/O addresses are probed looking for the "EATA"
733           signature. The addresses of all the PCI SCSI controllers reported
734           by the PCI subsystem are probed as well.
735
736           You want to read the start of <file:drivers/scsi/eata.c> and the
737           SCSI-HOWTO, available from
738           <http://www.tldp.org/docs.html#howto>.
739
740           To compile this driver as a module, choose M here: the
741           module will be called eata.
742
743 config SCSI_EATA_TAGGED_QUEUE
744         bool "enable tagged command queueing"
745         depends on SCSI_EATA
746         help
747           This is a feature of SCSI-2 which improves performance: the host
748           adapter can send several SCSI commands to a device's queue even if
749           previous commands haven't finished yet.
750           This is equivalent to the "eata=tc:y" boot option.
751
752 config SCSI_EATA_LINKED_COMMANDS
753         bool "enable elevator sorting"
754         depends on SCSI_EATA
755         help
756           This option enables elevator sorting for all probed SCSI disks and
757           CD-ROMs. It definitely reduces the average seek distance when doing
758           random seeks, but this does not necessarily result in a noticeable
759           performance improvement: your mileage may vary...
760           This is equivalent to the "eata=lc:y" boot option.
761
762 config SCSI_EATA_MAX_TAGS
763         int "maximum number of queued commands"
764         depends on SCSI_EATA
765         default "16"
766         help
767           This specifies how many SCSI commands can be maximally queued for
768           each probed SCSI device. You should reduce the default value of 16
769           only if you have disks with buggy or limited tagged command support.
770           Minimum is 2 and maximum is 62. This value is also the window size
771           used by the elevator sorting option above. The effective value used
772           by the driver for each probed SCSI device is reported at boot time.
773           This is equivalent to the "eata=mq:8" boot option.
774
775 config SCSI_EATA_PIO
776         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
777         depends on (ISA || EISA || PCI) && SCSI && BROKEN
778         ---help---
779           This driver supports all EATA-PIO protocol compliant SCSI Host
780           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
781           host adapters could also use this driver but are discouraged from
782           doing so, since this driver only supports hard disks and lacks
783           numerous features.  You might want to have a look at the SCSI-HOWTO,
784           available from <http://www.tldp.org/docs.html#howto>.
785
786           To compile this driver as a module, choose M here: the
787           module will be called eata_pio.
788
789 config SCSI_FUTURE_DOMAIN
790         tristate "Future Domain 16xx SCSI/AHA-2920A support"
791         depends on (ISA || PCI) && SCSI
792         select CHECK_SIGNATURE
793         ---help---
794           This is support for Future Domain's 16-bit SCSI host adapters
795           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
796           other adapters based on the Future Domain chipsets (Quantum
797           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
798           It is explained in section 3.7 of the SCSI-HOWTO, available from
799           <http://www.tldp.org/docs.html#howto>.
800
801           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
802           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
803           controller support"). This Future Domain driver works with the older
804           Adaptec AHA-2920A boards with a Future Domain chip on them.
805
806           To compile this driver as a module, choose M here: the
807           module will be called fdomain.
808
809 config SCSI_FD_MCS
810         tristate "Future Domain MCS-600/700 SCSI support"
811         depends on MCA_LEGACY && SCSI
812         ---help---
813           This is support for Future Domain MCS 600/700 MCA SCSI adapters.
814           Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
815           is identical to the MCS 700 and hence also supported by this driver.
816           This driver also supports the Reply SB16/SCSI card (the SCSI part).
817           It supports multiple adapters in the same system.
818
819           To compile this driver as a module, choose M here: the
820           module will be called fd_mcs.
821
822 config SCSI_GDTH
823         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
824         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
825         ---help---
826           Formerly called GDT SCSI Disk Array Controller Support.
827
828           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
829           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
830           in the kernel source in <file:drivers/scsi/gdth.c> and
831           <file:drivers/scsi/gdth.h>.
832
833           To compile this driver as a module, choose M here: the
834           module will be called gdth.
835
836 config SCSI_ISCI
837         tristate "Intel(R) C600 Series Chipset SAS Controller"
838         depends on PCI && SCSI
839         depends on X86
840         select SCSI_SAS_LIBSAS
841         ---help---
842           This driver supports the 6Gb/s SAS capabilities of the storage
843           control unit found in the Intel(R) C600 series chipset.
844
845 config SCSI_GENERIC_NCR5380
846         tristate "Generic NCR5380/53c400 SCSI PIO support"
847         depends on ISA && SCSI
848         select SCSI_SPI_ATTRS
849         ---help---
850           This is a driver for the old NCR 53c80 series of SCSI controllers
851           on boards using PIO. Most boards such as the Trantor T130 fit this
852           category, along with a large number of ISA 8bit controllers shipped
853           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
854           you should select the specific driver for that card rather than
855           generic 5380 support.
856
857           It is explained in section 3.8 of the SCSI-HOWTO, available from
858           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
859           of the box, you may have to change some settings in
860           <file:drivers/scsi/g_NCR5380.h>.
861
862           To compile this driver as a module, choose M here: the
863           module will be called g_NCR5380.
864
865 config SCSI_GENERIC_NCR5380_MMIO
866         tristate "Generic NCR5380/53c400 SCSI MMIO support"
867         depends on ISA && SCSI
868         select SCSI_SPI_ATTRS
869         ---help---
870           This is a driver for the old NCR 53c80 series of SCSI controllers
871           on boards using memory mapped I/O. 
872           It is explained in section 3.8 of the SCSI-HOWTO, available from
873           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
874           of the box, you may have to change some settings in
875           <file:drivers/scsi/g_NCR5380.h>.
876
877           To compile this driver as a module, choose M here: the
878           module will be called g_NCR5380_mmio.
879
880 config SCSI_GENERIC_NCR53C400
881         bool "Enable NCR53c400 extensions"
882         depends on SCSI_GENERIC_NCR5380
883         help
884           This enables certain optimizations for the NCR53c400 SCSI cards.
885           You might as well try it out.  Note that this driver will only probe
886           for the Trantor T130B in its default configuration; you might have
887           to pass a command line option to the kernel at boot time if it does
888           not detect your card.  See the file
889           <file:Documentation/scsi/g_NCR5380.txt> for details.
890
891 config SCSI_IBMMCA
892         tristate "IBMMCA SCSI support"
893         depends on MCA && SCSI
894         ---help---
895           This is support for the IBM SCSI adapter found in many of the PS/2
896           series computers.  These machines have an MCA bus, so you need to
897           answer Y to "MCA support" as well and read
898           <file:Documentation/mca.txt>.
899
900           If the adapter isn't found during boot (a common problem for models
901           56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
902           option, where <pun> is the id of the SCSI subsystem (usually 7, but
903           if that doesn't work check your reference diskette).  Owners of
904           model 95 with a LED-matrix-display can in addition activate some
905           activity info like under OS/2, but more informative, by setting
906           'ibmmcascsi=display' as an additional kernel parameter.  Try "man
907           bootparam" or see the documentation of your boot loader about how to
908           pass options to the kernel.
909
910           To compile this driver as a module, choose M here: the
911           module will be called ibmmca.
912
913 config IBMMCA_SCSI_ORDER_STANDARD
914         bool "Standard SCSI-order"
915         depends on SCSI_IBMMCA
916         ---help---
917           In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
918           are assigned to the drive letters, starting with the lowest SCSI-id
919           (physical number -- pun) to be drive C:, as seen from DOS and
920           similar operating systems. When looking into papers describing the
921           ANSI-SCSI-standard, this assignment of drives appears to be wrong.
922           The SCSI-standard follows a hardware-hierarchy which says that id 7
923           has the highest priority and id 0 the lowest. Therefore, the host
924           adapters are still today everywhere placed as SCSI-id 7 by default.
925           In the SCSI-standard, the drive letters express the priority of the
926           disk. C: should be the hard disk, or a partition on it, with the
927           highest priority. This must therefore be the disk with the highest
928           SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
929           original definition of the SCSI-standard as also industrial- and
930           process-control-machines, like VME-CPUs running under realtime-OSes
931           (e.g. LynxOS, OS9) do.
932
933           If you like to run Linux on your MCA-machine with the same
934           assignment of hard disks as seen from e.g. DOS or OS/2 on your
935           machine, which is in addition conformant to the SCSI-standard, you
936           must say Y here. This is also necessary for MCA-Linux users who want
937           to keep downward compatibility to older releases of the
938           IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
939           June 1997).
940
941           If you like to have the lowest SCSI-id assigned as drive C:, as
942           modern SCSI-BIOSes do, which does not conform to the standard, but
943           is widespread and common in the PC-world of today, you must say N
944           here. If unsure, say Y.
945
946 config IBMMCA_SCSI_DEV_RESET
947         bool "Reset SCSI-devices at boottime"
948         depends on SCSI_IBMMCA
949         ---help---
950           By default, SCSI-devices are reset when the machine is powered on.
951           However, some devices exist, like special-control-devices,
952           SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
953           not reset when switched on. If you say Y here, each device connected
954           to your SCSI-bus will be issued a reset-command after it has been
955           probed, while the kernel is booting. This may cause problems with
956           more modern devices, like hard disks, which do not appreciate these
957           reset commands, and can cause your system to hang. So say Y only if
958           you know that one of your older devices needs it; N is the safe
959           answer.
960
961 config SCSI_IPS
962         tristate "IBM ServeRAID support"
963         depends on PCI && SCSI
964         ---help---
965           This is support for the IBM ServeRAID hardware RAID controllers.
966           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
967           and <http://www-947.ibm.com/support/entry/portal/docdisplay?brand=5000008&lndocid=SERV-RAID>
968           for more information.  If this driver does not work correctly
969           without modification please contact the author by email at
970           <ipslinux@adaptec.com>.
971
972           To compile this driver as a module, choose M here: the
973           module will be called ips.
974
975 config SCSI_IBMVSCSI
976         tristate "IBM Virtual SCSI support"
977         depends on PPC_PSERIES
978         select SCSI_SRP_ATTRS
979         help
980           This is the IBM POWER Virtual SCSI Client
981
982           To compile this driver as a module, choose M here: the
983           module will be called ibmvscsic.
984
985 config SCSI_IBMVSCSIS
986         tristate "IBM Virtual SCSI Server support"
987         depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
988         help
989           This is the SRP target driver for IBM pSeries virtual environments.
990
991           The userspace component needed to initialize the driver and
992           documentation can be found:
993
994           http://stgt.berlios.de/
995
996           To compile this driver as a module, choose M here: the
997           module will be called ibmvstgt.
998
999 config SCSI_IBMVFC
1000         tristate "IBM Virtual FC support"
1001         depends on PPC_PSERIES && SCSI
1002         select SCSI_FC_ATTRS
1003         help
1004           This is the IBM POWER Virtual FC Client
1005
1006           To compile this driver as a module, choose M here: the
1007           module will be called ibmvfc.
1008
1009 config SCSI_IBMVFC_TRACE
1010         bool "enable driver internal trace"
1011         depends on SCSI_IBMVFC
1012         default y
1013         help
1014           If you say Y here, the driver will trace all commands issued
1015           to the adapter. Performance impact is minimal. Trace can be
1016           dumped using /sys/class/scsi_host/hostXX/trace.
1017
1018 config SCSI_INITIO
1019         tristate "Initio 9100U(W) support"
1020         depends on PCI && SCSI
1021         help
1022           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
1023           read the SCSI-HOWTO, available from
1024           <http://www.tldp.org/docs.html#howto>.
1025
1026           To compile this driver as a module, choose M here: the
1027           module will be called initio.
1028
1029 config SCSI_INIA100
1030         tristate "Initio INI-A100U2W support"
1031         depends on PCI && SCSI
1032         help
1033           This is support for the Initio INI-A100U2W SCSI host adapter.
1034           Please read the SCSI-HOWTO, available from
1035           <http://www.tldp.org/docs.html#howto>.
1036
1037           To compile this driver as a module, choose M here: the
1038           module will be called a100u2w.
1039
1040 config SCSI_PPA
1041         tristate "IOMEGA parallel port (ppa - older drives)"
1042         depends on SCSI && PARPORT_PC
1043         ---help---
1044           This driver supports older versions of IOMEGA's parallel port ZIP
1045           drive (a 100 MB removable media device).
1046
1047           Note that you can say N here if you have the SCSI version of the ZIP
1048           drive: it will be supported automatically if you said Y to the
1049           generic "SCSI disk support", above.
1050
1051           If you have the ZIP Plus drive or a more recent parallel port ZIP
1052           drive (if the supplied cable with the drive is labeled "AutoDetect")
1053           then you should say N here and Y to "IOMEGA parallel port (imm -
1054           newer drives)", below.
1055
1056           For more information about this driver and how to use it you should
1057           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
1058           the SCSI-HOWTO, which is available from
1059           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
1060           you will still be able to use the parallel port for other tasks,
1061           such as a printer; it is safe to compile both drivers into the
1062           kernel.
1063
1064           To compile this driver as a module, choose M here: the
1065           module will be called ppa.
1066
1067 config SCSI_IMM
1068         tristate "IOMEGA parallel port (imm - newer drives)"
1069         depends on SCSI && PARPORT_PC
1070         ---help---
1071           This driver supports newer versions of IOMEGA's parallel port ZIP
1072           drive (a 100 MB removable media device).
1073
1074           Note that you can say N here if you have the SCSI version of the ZIP
1075           drive: it will be supported automatically if you said Y to the
1076           generic "SCSI disk support", above.
1077
1078           If you have the ZIP Plus drive or a more recent parallel port ZIP
1079           drive (if the supplied cable with the drive is labeled "AutoDetect")
1080           then you should say Y here; if you have an older ZIP drive, say N
1081           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
1082
1083           For more information about this driver and how to use it you should
1084           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
1085           the SCSI-HOWTO, which is available from
1086           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
1087           you will still be able to use the parallel port for other tasks,
1088           such as a printer; it is safe to compile both drivers into the
1089           kernel.
1090
1091           To compile this driver as a module, choose M here: the
1092           module will be called imm.
1093
1094 config SCSI_IZIP_EPP16
1095         bool "ppa/imm option - Use slow (but safe) EPP-16"
1096         depends on SCSI_PPA || SCSI_IMM
1097         ---help---
1098           EPP (Enhanced Parallel Port) is a standard for parallel ports which
1099           allows them to act as expansion buses that can handle up to 64
1100           peripheral devices.
1101
1102           Some parallel port chipsets are slower than their motherboard, and
1103           so we have to control the state of the chipset's FIFO queue every
1104           now and then to avoid data loss. This will be done if you say Y
1105           here.
1106
1107           Generally, saying Y is the safe option and slows things down a bit.
1108
1109 config SCSI_IZIP_SLOW_CTR
1110         bool "ppa/imm option - Assume slow parport control register"
1111         depends on SCSI_PPA || SCSI_IMM
1112         help
1113           Some parallel ports are known to have excessive delays between
1114           changing the parallel port control register and good data being
1115           available on the parallel port data/status register. This option
1116           forces a small delay (1.0 usec to be exact) after changing the
1117           control register to let things settle out. Enabling this option may
1118           result in a big drop in performance but some very old parallel ports
1119           (found in 386 vintage machines) will not work properly.
1120
1121           Generally, saying N is fine.
1122
1123 config SCSI_NCR53C406A
1124         tristate "NCR53c406a SCSI support"
1125         depends on ISA && SCSI
1126         help
1127           This is support for the NCR53c406a SCSI host adapter.  For user
1128           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
1129           in the kernel source.  Also read the SCSI-HOWTO, available from
1130           <http://www.tldp.org/docs.html#howto>.
1131
1132           To compile this driver as a module, choose M here: the
1133           module will be called NCR53c406.
1134
1135 config SCSI_NCR_D700
1136         tristate "NCR Dual 700 MCA SCSI support"
1137         depends on MCA && SCSI
1138         select SCSI_SPI_ATTRS
1139         help
1140           This is a driver for the MicroChannel Dual 700 card produced by
1141           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1142           tries to negotiate sync and uses tag command queueing.
1143
1144           Unless you have an NCR manufactured machine, the chances are that
1145           you do not have this SCSI card, so say N.
1146
1147 config SCSI_LASI700
1148         tristate "HP Lasi SCSI support for 53c700/710"
1149         depends on GSC && SCSI
1150         select SCSI_SPI_ATTRS
1151         help
1152           This is a driver for the SCSI controller in the Lasi chip found in
1153           many PA-RISC workstations & servers.  If you do not know whether you
1154           have a Lasi chip, it is safe to say "Y" here.
1155
1156 config SCSI_SNI_53C710
1157         tristate "SNI RM SCSI support for 53c710"
1158         depends on SNI_RM && SCSI
1159         select SCSI_SPI_ATTRS
1160         select 53C700_LE_ON_BE
1161         help
1162           This is a driver for the onboard SCSI controller found in older
1163           SNI RM workstations & servers.
1164
1165 config 53C700_LE_ON_BE
1166         bool
1167         depends on SCSI_LASI700
1168         default y
1169
1170 config SCSI_STEX
1171         tristate "Promise SuperTrak EX Series support"
1172         depends on PCI && SCSI
1173         ---help---
1174           This driver supports Promise SuperTrak EX series storage controllers.
1175
1176           Promise provides Linux RAID configuration utility for these
1177           controllers. Please visit <http://www.promise.com> to download.
1178
1179           To compile this driver as a module, choose M here: the
1180           module will be called stex.
1181
1182 config 53C700_BE_BUS
1183         bool
1184         depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1185         default y
1186
1187 config SCSI_SYM53C8XX_2
1188         tristate "SYM53C8XX Version 2 SCSI support"
1189         depends on PCI && SCSI
1190         select SCSI_SPI_ATTRS
1191         ---help---
1192           This driver supports the whole NCR53C8XX/SYM53C8XX family of
1193           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
1194           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1195           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1196           controllers; you need to use the Fusion MPT driver for that.
1197
1198           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1199           information.
1200
1201 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1202         int "DMA addressing mode"
1203         depends on SCSI_SYM53C8XX_2
1204         default "1"
1205         ---help---
1206           This option only applies to PCI-SCSI chips that are PCI DAC
1207           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1208
1209           When set to 0, the driver will program the chip to only perform
1210           32-bit DMA.  When set to 1, the chip will be able to perform DMA
1211           to addresses up to 1TB.  When set to 2, the driver supports the
1212           full 64-bit DMA address range, but can only address 16 segments
1213           of 4 GB each.  This limits the total addressable range to 64 GB.
1214
1215           Most machines with less than 4GB of memory should use a setting
1216           of 0 for best performance.  If your machine has 4GB of memory
1217           or more, you should set this option to 1 (the default).
1218
1219           The still experimental value 2 (64 bit DMA addressing with 16
1220           x 4GB segments limitation) can be used on systems that require
1221           PCI address bits past bit 39 to be set for the addressing of
1222           memory using PCI DAC cycles.
1223
1224 config SCSI_SYM53C8XX_DEFAULT_TAGS
1225         int "Default tagged command queue depth"
1226         depends on SCSI_SYM53C8XX_2
1227         default "16"
1228         help
1229           This is the default value of the command queue depth the
1230           driver will announce to the generic SCSI layer for devices
1231           that support tagged command queueing. This value can be changed
1232           from the boot command line.  This is a soft limit that cannot
1233           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1234
1235 config SCSI_SYM53C8XX_MAX_TAGS
1236         int "Maximum number of queued commands"
1237         depends on SCSI_SYM53C8XX_2
1238         default "64"
1239         help
1240           This option allows you to specify the maximum number of commands
1241           that can be queued to any device, when tagged command queuing is
1242           possible. The driver supports up to 256 queued commands per device.
1243           This value is used as a compiled-in hard limit.
1244
1245 config SCSI_SYM53C8XX_MMIO
1246         bool "Use memory mapped IO"
1247         depends on SCSI_SYM53C8XX_2
1248         default y
1249         help
1250           Memory mapped IO is faster than Port IO.  Most people should
1251           answer Y here, but some machines may have problems.  If you have
1252           to answer N here, please report the problem to the maintainer.
1253
1254 config SCSI_IPR
1255         tristate "IBM Power Linux RAID adapter support"
1256         depends on PCI && SCSI && ATA
1257         select FW_LOADER
1258         ---help---
1259           This driver supports the IBM Power Linux family RAID adapters.
1260           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1261           as IBM iSeries 5702, 5703, 5709, and 570A.
1262
1263 config SCSI_IPR_TRACE
1264         bool "enable driver internal trace"
1265         depends on SCSI_IPR
1266         default y
1267         help
1268           If you say Y here, the driver will trace all commands issued
1269           to the adapter. Performance impact is minimal. Trace can be
1270           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1271
1272 config SCSI_IPR_DUMP
1273         bool "enable adapter dump support"
1274         depends on SCSI_IPR
1275         default y
1276         help
1277           If you say Y here, the driver will support adapter crash dump.
1278           If you enable this support, the iprdump daemon can be used
1279           to capture adapter failure analysis information.
1280
1281 config SCSI_ZALON
1282         tristate "Zalon SCSI support"
1283         depends on GSC && SCSI
1284         select SCSI_SPI_ATTRS
1285         help
1286           The Zalon is a GSC/HSC bus interface chip that sits between the
1287           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1288           C110, J200, J210 and some D, K & R-class machines.  It's also
1289           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1290           Say Y here if you have one of these machines or cards.
1291
1292 config SCSI_NCR_Q720
1293         tristate "NCR Quad 720 MCA SCSI support"
1294         depends on MCA && SCSI
1295         select SCSI_SPI_ATTRS
1296         help
1297           This is a driver for the MicroChannel Quad 720 card produced by
1298           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1299           tries to negotiate sync and uses tag command queueing.
1300
1301           Unless you have an NCR manufactured machine, the chances are that
1302           you do not have this SCSI card, so say N.
1303
1304 config SCSI_NCR53C8XX_DEFAULT_TAGS
1305         int "default tagged command queue depth"
1306         depends on SCSI_ZALON || SCSI_NCR_Q720
1307         default "8"
1308         ---help---
1309           "Tagged command queuing" is a feature of SCSI-2 which improves
1310           performance: the host adapter can send several SCSI commands to a
1311           device's queue even if previous commands haven't finished yet.
1312           Because the device is intelligent, it can optimize its operations
1313           (like head positioning) based on its own request queue. Some SCSI
1314           devices don't implement this properly; if you want to disable this
1315           feature, enter 0 or 1 here (it doesn't matter which).
1316
1317           The default value is 8 and should be supported by most hard disks.
1318           This value can be overridden from the boot command line using the
1319           'tags' option as follows (example):
1320           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1321           4, set queue depth to 16 for target 2 and target 3 on controller 0
1322           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1323
1324           The normal answer therefore is to go with the default 8 and to use
1325           a boot command line option for devices that need to use a different
1326           command queue depth.
1327
1328           There is no safe option other than using good SCSI devices.
1329
1330 config SCSI_NCR53C8XX_MAX_TAGS
1331         int "maximum number of queued commands"
1332         depends on SCSI_ZALON || SCSI_NCR_Q720
1333         default "32"
1334         ---help---
1335           This option allows you to specify the maximum number of commands
1336           that can be queued to any device, when tagged command queuing is
1337           possible. The default value is 32. Minimum is 2, maximum is 64.
1338           Modern hard disks are able to support 64 tags and even more, but
1339           do not seem to be faster when more than 32 tags are being used.
1340
1341           So, the normal answer here is to go with the default value 32 unless
1342           you are using very large hard disks with large cache (>= 1 MB) that
1343           are able to take advantage of more than 32 tagged commands.
1344
1345           There is no safe option and the default answer is recommended.
1346
1347 config SCSI_NCR53C8XX_SYNC
1348         int "synchronous transfers frequency in MHz"
1349         depends on SCSI_ZALON || SCSI_NCR_Q720
1350         default "20"
1351         ---help---
1352           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1353           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1354           are respectively the maximum data transfer rates in mega-transfers
1355           per second for each class.  For example, a FAST-20 Wide 16 device is
1356           able to transfer data at 20 million 16 bit packets per second for a
1357           total rate of 40 MB/s.
1358
1359           You may specify 0 if you want to only use asynchronous data
1360           transfers. This is the safest and slowest option. Otherwise, specify
1361           a value between 5 and 80, depending on the capability of your SCSI
1362           controller.  The higher the number, the faster the data transfer.
1363           Note that 80 should normally be ok since the driver decreases the
1364           value automatically according to the controller's capabilities.
1365
1366           Your answer to this question is ignored for controllers with NVRAM,
1367           since the driver will get this information from the user set-up.  It
1368           also can be overridden using a boot setup option, as follows
1369           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1370           for FAST-20 synchronous data transfer (20 mega-transfers per
1371           second).
1372
1373           The normal answer therefore is not to go with the default but to
1374           select the maximum value 80 allowing the driver to use the maximum
1375           value supported by each controller. If this causes problems with
1376           your SCSI devices, you should come back and decrease the value.
1377
1378           There is no safe option other than using good cabling, right
1379           terminations and SCSI conformant devices.
1380
1381 config SCSI_NCR53C8XX_NO_DISCONNECT
1382         bool "not allow targets to disconnect"
1383         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1384         help
1385           This option is only provided for safety if you suspect some SCSI
1386           device of yours to not support properly the target-disconnect
1387           feature. In that case, you would say Y here. In general however, to
1388           not allow targets to disconnect is not reasonable if there is more
1389           than 1 device on a SCSI bus. The normal answer therefore is N.
1390
1391 config SCSI_PAS16
1392         tristate "PAS16 SCSI support"
1393         depends on ISA && SCSI
1394         select SCSI_SPI_ATTRS
1395         ---help---
1396           This is support for a SCSI host adapter.  It is explained in section
1397           3.10 of the SCSI-HOWTO, available from
1398           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1399           of the box, you may have to change some settings in
1400           <file:drivers/scsi/pas16.h>.
1401
1402           To compile this driver as a module, choose M here: the
1403           module will be called pas16.
1404
1405 config SCSI_QLOGIC_FAS
1406         tristate "Qlogic FAS SCSI support"
1407         depends on ISA && SCSI
1408         ---help---
1409           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1410           FastSCSI! cards as well as any other card based on the FASXX chip
1411           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1412
1413           This driver does NOT support the PCI versions of these cards. The
1414           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1415           SCSI support"), below.
1416
1417           Information about this driver is contained in
1418           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1419           SCSI-HOWTO, available from
1420           <http://www.tldp.org/docs.html#howto>.
1421
1422           To compile this driver as a module, choose M here: the
1423           module will be called qlogicfas.
1424
1425 config SCSI_QLOGIC_1280
1426         tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1427         depends on PCI && SCSI
1428         help
1429           Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1430
1431           To compile this driver as a module, choose M here: the
1432           module will be called qla1280.
1433
1434 config SCSI_QLOGICPTI
1435         tristate "PTI Qlogic, ISP Driver"
1436         depends on SBUS && SCSI
1437         help
1438           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1439           controllers are known under Solaris as qpti and in the openprom as
1440           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1441           driven by a different driver.
1442
1443           To compile this driver as a module, choose M here: the
1444           module will be called qlogicpti.
1445
1446 source "drivers/scsi/qla2xxx/Kconfig"
1447 source "drivers/scsi/qla4xxx/Kconfig"
1448
1449 config SCSI_LPFC
1450         tristate "Emulex LightPulse Fibre Channel Support"
1451         depends on PCI && SCSI
1452         select SCSI_FC_ATTRS
1453         help
1454           This lpfc driver supports the Emulex LightPulse
1455           Family of Fibre Channel PCI host adapters.
1456
1457 config SCSI_LPFC_DEBUG_FS
1458         bool "Emulex LightPulse Fibre Channel debugfs Support"
1459         depends on SCSI_LPFC && DEBUG_FS
1460         help
1461           This makes debugging information from the lpfc driver
1462           available via the debugfs filesystem.
1463
1464 config SCSI_SIM710
1465         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1466         depends on (EISA || MCA) && SCSI
1467         select SCSI_SPI_ATTRS
1468         ---help---
1469           This driver is for NCR53c710 based SCSI host adapters.
1470
1471           It currently supports Compaq EISA cards and NCR MCA cards
1472
1473 config SCSI_SYM53C416
1474         tristate "Symbios 53c416 SCSI support"
1475         depends on ISA && SCSI
1476         ---help---
1477           This is support for the sym53c416 SCSI host adapter, the SCSI
1478           adapter that comes with some HP scanners. This driver requires that
1479           the sym53c416 is configured first using some sort of PnP
1480           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1481           are using isapnp then you need to compile this driver as a module
1482           and then load it using insmod after isapnp has run. The parameters
1483           of the configured card(s) should be passed to the driver. The format
1484           is:
1485
1486           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1487
1488           To compile this driver as a module, choose M here: the
1489           module will be called sym53c416.
1490
1491 config SCSI_DC395x
1492         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1493         depends on PCI && SCSI && EXPERIMENTAL
1494         ---help---
1495           This driver supports PCI SCSI host adapters based on the ASIC
1496           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1497
1498           This driver works, but is still in experimental status. So better
1499           have a bootable disk and a backup in case of emergency.
1500
1501           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1502
1503           To compile this driver as a module, choose M here: the
1504           module will be called dc395x.
1505
1506 config SCSI_DC390T
1507         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1508         depends on PCI && SCSI
1509         ---help---
1510           This driver supports PCI SCSI host adapters based on the Am53C974A
1511           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1512           PCscsi/PCnet (Am53/79C974) solutions.
1513
1514           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1515
1516           Note that this driver does NOT support Tekram DC390W/U/F, which are
1517           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1518
1519           To compile this driver as a module, choose M here: the
1520           module will be called tmscsim.
1521
1522 config SCSI_T128
1523         tristate "Trantor T128/T128F/T228 SCSI support"
1524         depends on ISA && SCSI
1525         select SCSI_SPI_ATTRS
1526         select CHECK_SIGNATURE
1527         ---help---
1528           This is support for a SCSI host adapter. It is explained in section
1529           3.11 of the SCSI-HOWTO, available from
1530           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1531           of the box, you may have to change some settings in
1532           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1533           Adaptec, and some former Trantor products are being sold under the
1534           Adaptec name.
1535
1536           To compile this driver as a module, choose M here: the
1537           module will be called t128.
1538
1539 config SCSI_U14_34F
1540         tristate "UltraStor 14F/34F support"
1541         depends on ISA && SCSI && ISA_DMA_API
1542         ---help---
1543           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1544           The source at <file:drivers/scsi/u14-34f.c> contains some
1545           information about this hardware.  If the driver doesn't work out of
1546           the box, you may have to change some settings in
1547           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1548           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1549           another driver for the same hardware: "UltraStor SCSI support",
1550           below.  You should say Y to both only if you want 24F support as
1551           well.
1552
1553           To compile this driver as a module, choose M here: the
1554           module will be called u14-34f.
1555
1556 config SCSI_U14_34F_TAGGED_QUEUE
1557         bool "enable tagged command queueing"
1558         depends on SCSI_U14_34F
1559         help
1560           This is a feature of SCSI-2 which improves performance: the host
1561           adapter can send several SCSI commands to a device's queue even if
1562           previous commands haven't finished yet.
1563           This is equivalent to the "u14-34f=tc:y" boot option.
1564
1565 config SCSI_U14_34F_LINKED_COMMANDS
1566         bool "enable elevator sorting"
1567         depends on SCSI_U14_34F
1568         help
1569           This option enables elevator sorting for all probed SCSI disks and
1570           CD-ROMs. It definitely reduces the average seek distance when doing
1571           random seeks, but this does not necessarily result in a noticeable
1572           performance improvement: your mileage may vary...
1573           This is equivalent to the "u14-34f=lc:y" boot option.
1574
1575 config SCSI_U14_34F_MAX_TAGS
1576         int "maximum number of queued commands"
1577         depends on SCSI_U14_34F
1578         default "8"
1579         help
1580           This specifies how many SCSI commands can be maximally queued for
1581           each probed SCSI device. You should reduce the default value of 8
1582           only if you have disks with buggy or limited tagged command support.
1583           Minimum is 2 and maximum is 14. This value is also the window size
1584           used by the elevator sorting option above. The effective value used
1585           by the driver for each probed SCSI device is reported at boot time.
1586           This is equivalent to the "u14-34f=mq:8" boot option.
1587
1588 config SCSI_ULTRASTOR
1589         tristate "UltraStor SCSI support"
1590         depends on X86 && ISA && SCSI
1591         ---help---
1592           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1593           adapter family.  This driver is explained in section 3.12 of the
1594           SCSI-HOWTO, available from
1595           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1596           of the box, you may have to change some settings in
1597           <file:drivers/scsi/ultrastor.h>.
1598
1599           Note that there is also another driver for the same hardware:
1600           "UltraStor 14F/34F support", above.
1601
1602           To compile this driver as a module, choose M here: the
1603           module will be called ultrastor.
1604
1605 config SCSI_NSP32
1606         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1607         depends on PCI && SCSI && !64BIT
1608         help
1609           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1610           SCSI host adapter. Please read the SCSI-HOWTO, available from
1611           <http://www.tldp.org/docs.html#howto>.
1612
1613           To compile this driver as a module, choose M here: the
1614           module will be called nsp32.
1615
1616 config SCSI_DEBUG
1617         tristate "SCSI debugging host simulator"
1618         depends on SCSI
1619         select CRC_T10DIF
1620         help
1621           This is a host adapter simulator that can simulate multiple hosts
1622           each with multiple dummy SCSI devices (disks). It defaults to one
1623           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1624           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1625           dummy disks are simulated, they share the same kernel RAM for 
1626           their storage. See <http://sg.danny.cz/sg/sdebug26.html> for more
1627           information. This driver is primarily of use to those testing the
1628           SCSI and block subsystems. If unsure, say N.
1629
1630 config SCSI_MESH
1631         tristate "MESH (Power Mac internal SCSI) support"
1632         depends on PPC32 && PPC_PMAC && SCSI
1633         help
1634           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1635           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1636           other Power Macintoshes do). Say Y to include support for this SCSI
1637           adaptor.
1638
1639           To compile this driver as a module, choose M here: the
1640           module will be called mesh.
1641
1642 config SCSI_MESH_SYNC_RATE
1643         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1644         depends on SCSI_MESH
1645         default "5"
1646         help
1647           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1648           drives a bus which is entirely internal to the machine (such as the
1649           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1650           operation at up to 10 MB/s. On machines where the SCSI bus
1651           controlled by the MESH can have external devices connected, it is
1652           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1653           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1654           to disable synchronous operation.
1655
1656 config SCSI_MESH_RESET_DELAY_MS
1657         int "initial bus reset delay (ms) (0 = no reset)"
1658         depends on SCSI_MESH
1659         default "4000"
1660
1661 config SCSI_MAC53C94
1662         tristate "53C94 (Power Mac external SCSI) support"
1663         depends on PPC32 && PPC_PMAC && SCSI
1664         help
1665           On Power Macintoshes (and clones) with two SCSI buses, the external
1666           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1667           machines which only have one SCSI bus, such as the 7200, also use
1668           the 53C94. Say Y to include support for the 53C94.
1669
1670           To compile this driver as a module, choose M here: the
1671           module will be called mac53c94.
1672
1673 source "drivers/scsi/arm/Kconfig"
1674
1675 config JAZZ_ESP
1676         bool "MIPS JAZZ FAS216 SCSI support"
1677         depends on MACH_JAZZ && SCSI
1678         select SCSI_SPI_ATTRS
1679         help
1680           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1681           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1682           systems.
1683
1684 config A3000_SCSI
1685         tristate "A3000 WD33C93A support"
1686         depends on AMIGA && SCSI
1687         help
1688           If you have an Amiga 3000 and have SCSI devices connected to the
1689           built-in SCSI controller, say Y. Otherwise, say N.
1690
1691           To compile this driver as a module, choose M here: the
1692           module will be called a3000.
1693
1694 config A2091_SCSI
1695         tristate "A2091/A590 WD33C93A support"
1696         depends on ZORRO && SCSI
1697         help
1698           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1699           say N.
1700
1701           To compile this driver as a module, choose M here: the
1702           module will be called a2091.
1703
1704 config GVP11_SCSI
1705         tristate "GVP Series II WD33C93A support"
1706         depends on ZORRO && SCSI
1707         ---help---
1708           If you have a Great Valley Products Series II SCSI controller,
1709           answer Y. Also say Y if you have a later model of GVP SCSI
1710           controller (such as the GVP A4008 or a Combo board). Otherwise,
1711           answer N. This driver does NOT work for the T-Rex series of
1712           accelerators from TekMagic and GVP-M.
1713
1714           To compile this driver as a module, choose M here: the
1715           module will be called gvp11.
1716
1717 config SCSI_A4000T
1718         tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
1719         depends on AMIGA && SCSI && EXPERIMENTAL
1720         select SCSI_SPI_ATTRS
1721         help
1722           If you have an Amiga 4000T and have SCSI devices connected to the
1723           built-in SCSI controller, say Y. Otherwise, say N.
1724
1725           To compile this driver as a module, choose M here: the
1726           module will be called a4000t.
1727
1728 config SCSI_ZORRO7XX
1729         tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
1730         depends on ZORRO && SCSI && EXPERIMENTAL
1731         select SCSI_SPI_ATTRS
1732         help
1733           Support for various NCR53c710-based SCSI controllers on Zorro
1734           expansion boards for the Amiga.
1735           This includes:
1736             - the Amiga 4091 Zorro III SCSI-2 controller,
1737             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1738               (info at
1739               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1740             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1741               accelerator card for the Amiga 1200,
1742             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1743
1744 config ATARI_SCSI
1745         tristate "Atari native SCSI support"
1746         depends on ATARI && SCSI
1747         select SCSI_SPI_ATTRS
1748         select NVRAM
1749         ---help---
1750           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1751           Falcon, ...) say Y to get it supported. Of course also, if you have
1752           a compatible SCSI controller (e.g. for Medusa).
1753
1754           To compile this driver as a module, choose M here: the
1755           module will be called atari_scsi.
1756
1757           This driver supports both styles of NCR integration into the
1758           system: the TT style (separate DMA), and the Falcon style (via
1759           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1760           in the Hades (without DMA).
1761
1762 config ATARI_SCSI_TOSHIBA_DELAY
1763         bool "Long delays for Toshiba CD-ROMs"
1764         depends on ATARI_SCSI
1765         help
1766           This option increases the delay after a SCSI arbitration to
1767           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1768           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1769           would impact performance a bit, so say N.
1770
1771 config ATARI_SCSI_RESET_BOOT
1772         bool "Reset SCSI-devices at boottime"
1773         depends on ATARI_SCSI
1774         help
1775           Reset the devices on your Atari whenever it boots.  This makes the
1776           boot process fractionally longer but may assist recovery from errors
1777           that leave the devices with SCSI operations partway completed.
1778
1779 config MAC_SCSI
1780         bool "Macintosh NCR5380 SCSI"
1781         depends on MAC && SCSI=y
1782         select SCSI_SPI_ATTRS
1783         help
1784           This is the NCR 5380 SCSI controller included on most of the 68030
1785           based Macintoshes.  If you have one of these say Y and read the
1786           SCSI-HOWTO, available from
1787           <http://www.tldp.org/docs.html#howto>.
1788
1789 config SCSI_MAC_ESP
1790         tristate "Macintosh NCR53c9[46] SCSI"
1791         depends on MAC && SCSI
1792         select SCSI_SPI_ATTRS
1793         help
1794           This is the NCR 53c9x SCSI controller found on most of the 68040
1795           based Macintoshes.
1796
1797           To compile this driver as a module, choose M here: the module
1798           will be called mac_esp.
1799
1800 config MVME147_SCSI
1801         bool "WD33C93 SCSI driver for MVME147"
1802         depends on MVME147 && SCSI=y
1803         select SCSI_SPI_ATTRS
1804         help
1805           Support for the on-board SCSI controller on the Motorola MVME147
1806           single-board computer.
1807
1808 config MVME16x_SCSI
1809         tristate "NCR53C710 SCSI driver for MVME16x"
1810         depends on MVME16x && SCSI
1811         select SCSI_SPI_ATTRS
1812         help
1813           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1814           SCSI controller chip.  Almost everyone using one of these boards
1815           will want to say Y to this question.
1816
1817 config BVME6000_SCSI
1818         tristate "NCR53C710 SCSI driver for BVME6000"
1819         depends on BVME6000 && SCSI
1820         select SCSI_SPI_ATTRS
1821         help
1822           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1823           SCSI controller chip.  Almost everyone using one of these boards
1824           will want to say Y to this question.
1825
1826 config SUN3_SCSI
1827         tristate "Sun3 NCR5380 SCSI"
1828         depends on SUN3 && SCSI
1829         select SCSI_SPI_ATTRS
1830         help
1831           This option will enable support for the OBIO (onboard io) NCR5380
1832           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1833           "Sun3" type VME scsi controllers also based on the NCR5380.
1834           General Linux information on the Sun 3 series (now discontinued)
1835           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1836
1837 config SUN3X_ESP
1838         bool "Sun3x ESP SCSI"
1839         depends on SUN3X && SCSI=y
1840         select SCSI_SPI_ATTRS
1841         help
1842           The ESP was an on-board SCSI controller used on Sun 3/80
1843           machines.  Say Y here to compile in support for it.
1844
1845 config SCSI_SUNESP
1846         tristate "Sparc ESP Scsi Driver"
1847         depends on SBUS && SCSI
1848         select SCSI_SPI_ATTRS
1849         help
1850           This is the driver for the Sun ESP SCSI host adapter. The ESP
1851           chipset is present in most SPARC SBUS-based computers and
1852           supports the Emulex family of ESP SCSI chips (esp100, esp100A,
1853           esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
1854
1855           To compile this driver as a module, choose M here: the
1856           module will be called sun_esp.
1857
1858 config ZFCP
1859         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1860         depends on S390 && QDIO && SCSI
1861         select SCSI_FC_ATTRS
1862         help
1863           If you want to access SCSI devices attached to your IBM eServer
1864           zSeries by means of Fibre Channel interfaces say Y.
1865           For details please refer to the documentation provided by IBM at
1866           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1867
1868           This driver is also available as a module. This module will be
1869           called zfcp. If you want to compile it as a module, say M here
1870           and read <file:Documentation/kbuild/modules.txt>.
1871
1872 config SCSI_PMCRAID
1873         tristate "PMC SIERRA Linux MaxRAID adapter support"
1874         depends on PCI && SCSI && NET
1875         ---help---
1876           This driver supports the PMC SIERRA MaxRAID adapters.
1877
1878 config SCSI_PM8001
1879         tristate "PMC-Sierra SPC 8001 SAS/SATA Based Host Adapter driver"
1880         depends on PCI && SCSI
1881         select SCSI_SAS_LIBSAS
1882         help
1883           This driver supports PMC-Sierra PCIE SAS/SATA 8x6G SPC 8001 chip
1884           based host adapters.
1885
1886 config SCSI_SRP
1887         tristate "SCSI RDMA Protocol helper library"
1888         depends on SCSI && PCI
1889         select SCSI_TGT
1890         help
1891           If you wish to use SRP target drivers, say Y.
1892
1893           To compile this driver as a module, choose M here: the
1894           module will be called libsrp.
1895
1896 config SCSI_BFA_FC
1897         tristate "Brocade BFA Fibre Channel Support"
1898         depends on PCI && SCSI
1899         select SCSI_FC_ATTRS
1900         help
1901           This bfa driver supports all Brocade PCIe FC/FCOE host adapters.
1902
1903           To compile this driver as a module, choose M here. The module will
1904           be called bfa.
1905
1906 config SCSI_VIRTIO
1907         tristate "virtio-scsi support (EXPERIMENTAL)"
1908         depends on EXPERIMENTAL && VIRTIO
1909         help
1910           This is the virtual HBA driver for virtio.  If the kernel will
1911           be used in a virtual machine, say Y or M.
1912
1913
1914 endif # SCSI_LOWLEVEL
1915
1916 source "drivers/scsi/pcmcia/Kconfig"
1917
1918 source "drivers/scsi/device_handler/Kconfig"
1919
1920 source "drivers/scsi/osd/Kconfig"
1921
1922 endmenu