apm_power: calculate to_full/to_empty time using energy
authorAnton Vorontsov <cbou@mail.ru>
Thu, 4 Oct 2007 21:05:00 +0000 (01:05 +0400)
committerAnton Vorontsov <cbou@mail.ru>
Thu, 4 Oct 2007 21:05:00 +0000 (01:05 +0400)
This patch adds ability to calculate time using energy.
Needed to calculate time_to_full for PMU batteries.

Signed-off-by: Anton Vorontsov <cbou@mail.ru>
drivers/power/apm_power.c

index 3928e7c..bbf3ee1 100644 (file)
@@ -87,41 +87,63 @@ static void find_main_battery(void)
        }
 }
 
-static int calculate_time(int status)
+static int calculate_time(int status, int using_charge)
 {
-       union power_supply_propval charge_full, charge_empty;
-       union power_supply_propval charge, I;
+       union power_supply_propval full;
+       union power_supply_propval empty;
+       union power_supply_propval cur;
+       union power_supply_propval I;
+       enum power_supply_property full_prop;
+       enum power_supply_property full_design_prop;
+       enum power_supply_property empty_prop;
+       enum power_supply_property empty_design_prop;
+       enum power_supply_property cur_avg_prop;
+       enum power_supply_property cur_now_prop;
 
-       if (MPSY_PROP(CHARGE_FULL, &charge_full)) {
-               /* if battery can't report this property, use design value */
-               if (MPSY_PROP(CHARGE_FULL_DESIGN, &charge_full))
+       if (MPSY_PROP(CURRENT_AVG, &I)) {
+               /* if battery can't report average value, use momentary */
+               if (MPSY_PROP(CURRENT_NOW, &I))
                        return -1;
        }
 
-       if (MPSY_PROP(CHARGE_EMPTY, &charge_empty)) {
-               /* if battery can't report this property, use design value */
-               if (MPSY_PROP(CHARGE_EMPTY_DESIGN, &charge_empty))
-                       charge_empty.intval = 0;
+       if (using_charge) {
+               full_prop = POWER_SUPPLY_PROP_CHARGE_FULL;
+               full_design_prop = POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN;
+               empty_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
+               empty_design_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
+               cur_avg_prop = POWER_SUPPLY_PROP_CHARGE_AVG;
+               cur_now_prop = POWER_SUPPLY_PROP_CHARGE_NOW;
+       } else {
+               full_prop = POWER_SUPPLY_PROP_ENERGY_FULL;
+               full_design_prop = POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN;
+               empty_prop = POWER_SUPPLY_PROP_ENERGY_EMPTY;
+               empty_design_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
+               cur_avg_prop = POWER_SUPPLY_PROP_ENERGY_AVG;
+               cur_now_prop = POWER_SUPPLY_PROP_ENERGY_NOW;
        }
 
-       if (MPSY_PROP(CHARGE_AVG, &charge)) {
-               /* if battery can't report average value, use momentary */
-               if (MPSY_PROP(CHARGE_NOW, &charge))
+       if (_MPSY_PROP(full_prop, &full)) {
+               /* if battery can't report this property, use design value */
+               if (_MPSY_PROP(full_design_prop, &full))
                        return -1;
        }
 
-       if (MPSY_PROP(CURRENT_AVG, &I)) {
+       if (_MPSY_PROP(empty_prop, &empty)) {
+               /* if battery can't report this property, use design value */
+               if (_MPSY_PROP(empty_design_prop, &empty))
+                       empty.intval = 0;
+       }
+
+       if (_MPSY_PROP(cur_avg_prop, &cur)) {
                /* if battery can't report average value, use momentary */
-               if (MPSY_PROP(CURRENT_NOW, &I))
+               if (_MPSY_PROP(cur_now_prop, &cur))
                        return -1;
        }
 
        if (status == POWER_SUPPLY_STATUS_CHARGING)
-               return ((charge.intval - charge_full.intval) * 60L) /
-                      I.intval;
+               return ((cur.intval - full.intval) * 60L) / I.intval;
        else
-               return -((charge.intval - charge_empty.intval) * 60L) /
-                       I.intval;
+               return -((cur.intval - empty.intval) * 60L) / I.intval;
 }
 
 static int calculate_capacity(int using_charge)
@@ -238,16 +260,22 @@ static void apm_battery_apm_get_power_status(struct apm_power_info *info)
 
        if (status.intval == POWER_SUPPLY_STATUS_CHARGING) {
                if (!MPSY_PROP(TIME_TO_FULL_AVG, &time_to_full) ||
-                               !MPSY_PROP(TIME_TO_FULL_NOW, &time_to_full))
+                               !MPSY_PROP(TIME_TO_FULL_NOW, &time_to_full)) {
                        info->time = time_to_full.intval / 60;
-               else
-                       info->time = calculate_time(status.intval);
+               } else {
+                       info->time = calculate_time(status.intval, 0);
+                       if (info->time == -1)
+                               info->time = calculate_time(status.intval, 1);
+               }
        } else {
                if (!MPSY_PROP(TIME_TO_EMPTY_AVG, &time_to_empty) ||
-                               !MPSY_PROP(TIME_TO_EMPTY_NOW, &time_to_empty))
+                             !MPSY_PROP(TIME_TO_EMPTY_NOW, &time_to_empty)) {
                        info->time = time_to_empty.intval / 60;
-               else
-                       info->time = calculate_time(status.intval);
+               } else {
+                       info->time = calculate_time(status.intval, 0);
+                       if (info->time == -1)
+                               info->time = calculate_time(status.intval, 1);
+               }
        }
 
        up(&power_supply_class->sem);