s390/sclp: properly detect line mode console
authorChristian Borntraeger <borntraeger@de.ibm.com>
Tue, 17 Sep 2013 11:28:50 +0000 (13:28 +0200)
committerMartin Schwidefsky <schwidefsky@de.ibm.com>
Mon, 30 Sep 2013 11:04:39 +0000 (13:04 +0200)
To detect a line mode console we need a message event type
for the receive mask and a command event type for the send mask.
Checking for a MSG event in the sclp send mask was wrong and
might result in line mode consoles not being detected.

Signed-off-by: Christian Borntraeger <borntraeger@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
drivers/s390/char/sclp_cmd.c

index 8cd34bf..77df9cb 100644 (file)
@@ -145,9 +145,11 @@ bool __init sclp_has_linemode(void)
 
        if (sccb->header.response_code != 0x20)
                return 0;
-       if (sccb->sclp_send_mask & (EVTYP_MSG_MASK | EVTYP_PMSGCMD_MASK))
-               return 1;
-       return 0;
+       if (!(sccb->sclp_send_mask & (EVTYP_OPCMD_MASK | EVTYP_PMSGCMD_MASK)))
+               return 0;
+       if (!(sccb->sclp_receive_mask & (EVTYP_MSG_MASK | EVTYP_PMSGCMD_MASK)))
+               return 0;
+       return 1;
 }
 
 bool __init sclp_has_vt220(void)