tg3: Fix flow control settings not propagated to hardware
authorNithin Sujir <nsujir@broadcom.com>
Tue, 9 Apr 2013 08:48:01 +0000 (08:48 +0000)
committerDavid S. Miller <davem@davemloft.net>
Tue, 9 Apr 2013 19:14:14 +0000 (15:14 -0400)
In tg3_setup_copper_phy(), if autonegotiation is disabled, we need to
relink only if the speed or duplex does not match the configured
setting.  If flow control does not match, a relink is not necessary as
flow control is not a PHY setting.  Later on, we'll call
tg3_setup_flow_ctrl() to set up the MAC to the desired flow control
settings if we're in full duplex mode.

Signed-off-by: Nithin Nayak Sujir <nsujir@broadcom.com>
Signed-off-by: Michael Chan <mchan@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/broadcom/tg3.c

index a4416b0..d044adf 100644 (file)
@@ -4587,9 +4587,7 @@ static int tg3_setup_copper_phy(struct tg3 *tp, int force_reset)
                } else {
                        if (!(bmcr & BMCR_ANENABLE) &&
                            tp->link_config.speed == current_speed &&
-                           tp->link_config.duplex == current_duplex &&
-                           tp->link_config.flowctrl ==
-                           tp->link_config.active_flowctrl) {
+                           tp->link_config.duplex == current_duplex) {
                                current_link_up = 1;
                        }
                }