The interrupt status bits in PHY register 5 are cleared by writing a one
bit. To avoid clearing them unadvertently, do not write them back when
they were read as set, but only when they have been explicitly requested
to be set.
Signed-off-by: Clemens Ladisch <clemens@ladisch.de> Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>