iio: adc: spmi-vadc: Fix overflow in output value normalization
authorIvan T. Ivanov <ivan.ivanov@linaro.org>
Fri, 17 Apr 2015 14:51:08 +0000 (17:51 +0300)
committerJonathan Cameron <jic23@kernel.org>
Sat, 18 Apr 2015 16:40:04 +0000 (17:40 +0100)
With 'dx' equal to 0.625V and 15 bit ADC, calculations overflow
when difference against GND is ~20% of the ADC range. Fix this.

Signed-off-by: Ivan T. Ivanov <ivan.ivanov@linaro.org>
Cc: <stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
drivers/iio/adc/qcom-spmi-vadc.c

index 3211729..0c4618b 100644 (file)
@@ -18,6 +18,7 @@
 #include <linux/iio/iio.h>
 #include <linux/interrupt.h>
 #include <linux/kernel.h>
+#include <linux/math64.h>
 #include <linux/module.h>
 #include <linux/of.h>
 #include <linux/platform_device.h>
@@ -471,11 +472,11 @@ static s32 vadc_calibrate(struct vadc_priv *vadc,
                          const struct vadc_channel_prop *prop, u16 adc_code)
 {
        const struct vadc_prescale_ratio *prescale;
-       s32 voltage;
+       s64 voltage;
 
        voltage = adc_code - vadc->graph[prop->calibration].gnd;
        voltage *= vadc->graph[prop->calibration].dx;
-       voltage = voltage / vadc->graph[prop->calibration].dy;
+       voltage = div64_s64(voltage, vadc->graph[prop->calibration].dy);
 
        if (prop->calibration == VADC_CALIB_ABSOLUTE)
                voltage += vadc->graph[prop->calibration].dx;
@@ -487,7 +488,7 @@ static s32 vadc_calibrate(struct vadc_priv *vadc,
 
        voltage = voltage * prescale->den;
 
-       return voltage / prescale->num;
+       return div64_s64(voltage, prescale->num);
 }
 
 static int vadc_decimation_from_dt(u32 value)