staging: comedi: amplc_dio200_common: use comedi_cmd pointer
authorH Hartley Sweeten <hsweeten@visionengravers.com>
Tue, 27 May 2014 17:30:47 +0000 (10:30 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 28 May 2014 21:28:52 +0000 (14:28 -0700)
Use the local variable to access the comedi_cmd as a pointer
in dio200_read_scan_intr() instead of getting to it from the
comedi_subdevice pointer.

Remove the unnecessary local variable 'len', this is just the
cmd->chanlist_len.

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/amplc_dio200_common.c

index 1a580c3..3edaa40 100644 (file)
@@ -312,12 +312,11 @@ static void dio200_read_scan_intr(struct comedi_device *dev,
        struct dio200_subdev_intr *subpriv = s->private;
        struct comedi_cmd *cmd = &s->async->cmd;
        unsigned short val;
-       unsigned int n, ch, len;
+       unsigned int n, ch;
 
        val = 0;
-       len = s->async->cmd.chanlist_len;
-       for (n = 0; n < len; n++) {
-               ch = CR_CHAN(s->async->cmd.chanlist[n]);
+       for (n = 0; n < cmd->chanlist_len; n++) {
+               ch = CR_CHAN(cmd->chanlist[n]);
                if (triggered & (1U << ch))
                        val |= (1U << n);
        }