staging/comedi/drivers fix spelling errors
authorAlexandru Guduleasa <alexandru.guduleasa@gmail.com>
Fri, 9 Mar 2012 20:29:01 +0000 (22:29 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 9 Mar 2012 21:14:08 +0000 (13:14 -0800)
Fix the following spelling errors:
inital -> initial
continous -> continuous
aquisition -> acquisition
aquisitions -> acquisitions
immidiately -> immediately

Signed-off-by: Alexandru Guduleasa <alexandru.guduleasa@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/usbduxsigma.c

index ca6bcf8..63c9b6d 100644 (file)
@@ -39,7 +39,7 @@ Status: testing
  *
  *
  * Revision history:
- *   0.1: inital version
+ *   0.1: initial version
  *   0.2: all basic functions implemented, digital I/O only for one port
  *   0.3: proper vendor ID and driver name
  *   0.4: fixed D/A voltage range
@@ -235,16 +235,16 @@ struct usbduxsub {
        short int ao_cmd_running;
        /* pwm is running */
        short int pwm_cmd_running;
-       /* continous aquisition */
-       short int ai_continous;
-       short int ao_continous;
+       /* continuous acquisition */
+       short int ai_continuous;
+       short int ao_continuous;
        /* number of samples to acquire */
        int ai_sample_count;
        int ao_sample_count;
        /* time between samples in units of the timer */
        unsigned int ai_timer;
        unsigned int ao_timer;
-       /* counter between aquisitions */
+       /* counter between acquisitions */
        unsigned int ai_counter;
        unsigned int ao_counter;
        /* interval in frames/uframes */
@@ -455,8 +455,8 @@ static void usbduxsub_ai_IsocIrq(struct urb *urb)
        this_usbduxsub->ai_counter = this_usbduxsub->ai_timer;
 
        /* test, if we transmit only a fixed number of samples */
-       if (!(this_usbduxsub->ai_continous)) {
-               /* not continous, fixed number of samples */
+       if (!(this_usbduxsub->ai_continuous)) {
+               /* not continuous, fixed number of samples */
                this_usbduxsub->ai_sample_count--;
                /* all samples received? */
                if (this_usbduxsub->ai_sample_count < 0) {
@@ -607,8 +607,8 @@ static void usbduxsub_ao_IsocIrq(struct urb *urb)
                /* timer zero */
                this_usbduxsub->ao_counter = this_usbduxsub->ao_timer;
 
-               /* handle non continous aquisition */
-               if (!(this_usbduxsub->ao_continous)) {
+               /* handle non continuous acquisition */
+               if (!(this_usbduxsub->ao_continuous)) {
                        /* fixed number of samples */
                        this_usbduxsub->ao_sample_count--;
                        if (this_usbduxsub->ao_sample_count < 0) {
@@ -925,7 +925,7 @@ static int usbdux_ai_cmdtest(struct comedi_device *dev,
        if (!cmd->scan_begin_src || tmp != cmd->scan_begin_src)
                err++;
 
-       /* scanning is continous */
+       /* scanning is continuous */
        tmp = cmd->convert_src;
        cmd->convert_src &= TRIG_NOW;
        if (!cmd->convert_src || tmp != cmd->convert_src)
@@ -1193,7 +1193,7 @@ static int usbdux_ai_cmd(struct comedi_device *dev, struct comedi_subdevice *s)
                up(&this_usbduxsub->sem);
                return -EBUSY;
        }
-       /* set current channel of the running aquisition to zero */
+       /* set current channel of the running acquisition to zero */
        s->async->cur_chan = 0;
 
        /* first the number of channels per time step */
@@ -1261,10 +1261,10 @@ static int usbdux_ai_cmd(struct comedi_device *dev, struct comedi_subdevice *s)
        if (cmd->stop_src == TRIG_COUNT) {
                /* data arrives as one packet */
                this_usbduxsub->ai_sample_count = cmd->stop_arg;
-               this_usbduxsub->ai_continous = 0;
+               this_usbduxsub->ai_continuous = 0;
        } else {
-               /* continous aquisition */
-               this_usbduxsub->ai_continous = 1;
+               /* continuous acquisition */
+               this_usbduxsub->ai_continuous = 1;
                this_usbduxsub->ai_sample_count = 0;
        }
 
@@ -1586,7 +1586,7 @@ static int usbdux_ao_cmdtest(struct comedi_device *dev,
        /* just now we scan also in the high speed mode every frame */
        /* this is due to ehci driver limitations */
        if (0) {                /* (this_usbduxsub->high_speed) */
-               /* start immidiately a new scan */
+               /* start immediately a new scan */
                /* the sampling rate is set by the coversion rate */
                cmd->scan_begin_src &= TRIG_FOLLOW;
        } else {
@@ -1596,7 +1596,7 @@ static int usbdux_ao_cmdtest(struct comedi_device *dev,
        if (!cmd->scan_begin_src || tmp != cmd->scan_begin_src)
                err++;
 
-       /* scanning is continous */
+       /* scanning is continuous */
        tmp = cmd->convert_src;
 
        /* all conversion events happen simultaneously */
@@ -1710,7 +1710,7 @@ static int usbdux_ao_cmd(struct comedi_device *dev, struct comedi_subdevice *s)
        dev_dbg(&this_usbduxsub->interface->dev,
                "comedi%d: %s\n", dev->minor, __func__);
 
-       /* set current channel of the running aquisition to zero */
+       /* set current channel of the running acquisition to zero */
        s->async->cur_chan = 0;
        for (i = 0; i < cmd->chanlist_len; ++i) {
                chan = CR_CHAN(cmd->chanlist[i]);
@@ -1759,7 +1759,7 @@ static int usbdux_ao_cmd(struct comedi_device *dev, struct comedi_subdevice *s)
        this_usbduxsub->ao_counter = this_usbduxsub->ao_timer;
 
        if (cmd->stop_src == TRIG_COUNT) {
-               /* not continous */
+               /* not continuous */
                /* counter */
                /* high speed also scans everything at once */
                if (0) {        /* (this_usbduxsub->high_speed) */
@@ -1771,10 +1771,10 @@ static int usbdux_ao_cmd(struct comedi_device *dev, struct comedi_subdevice *s)
                        /* data arrives as one packet */
                        this_usbduxsub->ao_sample_count = cmd->stop_arg;
                }
-               this_usbduxsub->ao_continous = 0;
+               this_usbduxsub->ao_continuous = 0;
        } else {
-               /* continous aquisition */
-               this_usbduxsub->ao_continous = 1;
+               /* continuous acquisition */
+               this_usbduxsub->ao_continuous = 1;
                this_usbduxsub->ao_sample_count = 0;
        }