i2c: Blackfin TWI: fix transfer errors with repeat start
authorFrank Shew <fshew@geometrics.com>
Tue, 19 May 2009 11:23:49 +0000 (07:23 -0400)
committerBen Dooks <ben-linux@fluff.org>
Sat, 13 Jun 2009 09:39:25 +0000 (10:39 +0100)
commit94327d009e3aa20214e9dfa486a1fd14445fe736
treebb34db58161a22f60c73bcea08fefbde1db6b5a9
parent57a8f32eafa6f36ea3a128e8b13f353c5a3ca9b2
i2c: Blackfin TWI: fix transfer errors with repeat start

We have a custom BF537 board with an I2C RTC (MAX DS3231) running
uclinux 2007R1 for some time. Recently during migration to 2008R1.5-RC3
we losted access to the RTC. The RTC driver calls 'i2c_transfer()' which
in turns calls 'bfin_twi_master_xfer()' in i2c-bfin-twi.c.

Compared with 2007R1, it looks like the 2008R1.5 version of i2c-bin-twi.c
has a new mode 'TWI_I2C-MODE_REPEAT' which corresponds to the Repeat Start
Condition described in the HRM. However, according to the HRM, at XMIT or
RECV interrupt and when the data count is 0, not only is the RESTART bit
supposed to be set, but MDIR must also be set if the next operation is a
receive sequence, and cleared if not. Currently there is no code that looks
at the I2C_M_RD bit in the flag from the next cur_msg and set/clear the MDIR
flag accordingly at the same time that the RSTART bit is set. Instead, MDIR
is set or cleared (by OR'ing with 0?) after the RESTART bit has been cleared
during handling of MCOMP interrupt.

It appears that this is causing our failure with reading the RTC, as a
quick patch to set/clear MDIR when RESTART is set seem to solve our problem.

Signed-off-by: Frank Shew <fshew@geometrics.com>
Signed-off-by: Sonic Zhang <sonic.zhang@analog.com>
Signed-off-by: Mike Frysinger <vapier@gentoo.org>
Signed-off-by: Bryan Wu <cooloney@kernel.org>
[ben-linux@fluff.org: shorted subject]
Signed-off-by: Ben Dooks <ben-linux@fluff.org>
drivers/i2c/busses/i2c-bfin-twi.c