w1: w1 temp calculation overflow fix
authorIan Dall <ian@beware.dropbear.id.au>
Wed, 11 Feb 2009 21:04:46 +0000 (13:04 -0800)
committerLinus Torvalds <torvalds@linux-foundation.org>
Wed, 11 Feb 2009 22:25:37 +0000 (14:25 -0800)
commit507e2fbaaacb6f164b4125b87c5002f95143174b
tree6407941a4dfecbd71e6222f2d640f3c5ed2715d0
parent4d48a542b42747c36a5937447d9c3de7c897ea50
w1: w1 temp calculation overflow fix

Addresses http://bugzilla.kernel.org/show_bug.cgi?id=12646

When the temperature exceeds 32767 milli-degrees the temperature overflows
to -32768 millidegrees.  These are bothe well within the -55 - +125 degree
range for the sensor.

Fix overflow in left-shift of a u8.

Signed-off-by: Ian Dall <ian@beware.dropbear.id.au>
Signed-off-by: Evgeniy Polyakov <zbr@ioremap.net>
Cc: <stable@kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
drivers/w1/slaves/w1_therm.c