serial: pl011: handle corruption at high clock speeds
authorLinus Walleij <linus.walleij@linaro.org>
Wed, 26 Sep 2012 15:21:36 +0000 (17:21 +0200)
committerBen Hutchings <ben@decadent.org.uk>
Wed, 17 Oct 2012 02:49:02 +0000 (03:49 +0100)
commit4ac206a50c319f692aab900408f949b04f8deab7
treedae6a5db60cb56b308e2b13373b1a6aca1ce9a29
parent96311cce7d8e427aad023c8eea6ba3a08b70e754
serial: pl011: handle corruption at high clock speeds

commit c5dd553b9fd069892c9e2de734f4f604e280fa7a upstream.

This works around a few glitches in the ST version of the PL011
serial driver when using very high baud rates, as we do in the
Ux500: 3, 3.25, 4 and 4.05 Mbps.

Problem Observed/rootcause:

When using high baud-rates, and the baudrate*8 is getting close to
the provided clock frequency (so a division factor close to 1), when
using bursts of characters (so they are abutted), then it seems as if
there is not enough time to detect the beginning of the start-bit which
is a timing reference for the entire character, and thus the sampling
moment of character bits is moving towards the end of each bit, instead
of the middle.

Fix:
Increase slightly the RX baud rate of the UART above the theoretical
baudrate by 5%. This will definitely give more margin time to the
UART_RX to correctly sample the data at the middle of the bit period.

Also fix the ages old copy-paste error in the very stressed comment,
it's referencing the registers used in the PL010 driver rather than
the PL011 ones.

Signed-off-by: Guillaume Jaunet <guillaume.jaunet@stericsson.com>
Signed-off-by: Christophe Arnal <christophe.arnal@stericsson.com>
Signed-off-by: Matthias Locher <matthias.locher@stericsson.com>
Signed-off-by: Rajanikanth HV <rajanikanth.hv@stericsson.com>
Cc: Bibek Basu <bibek.basu@stericsson.com>
Cc: Par-Gunnar Hjalmdahl <par-gunnar.hjalmdahl@stericsson.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: Ben Hutchings <ben@decadent.org.uk>
drivers/tty/serial/amba-pl011.c