USB: gadget rndis: stop windows self-immolation
authorDavid Brownell <dbrownell@users.sourceforge.net>
Sun, 16 Nov 2008 03:53:21 +0000 (19:53 -0800)
committerGrazvydas Ignotas <notasas@gmail.com>
Sun, 15 Feb 2009 15:27:49 +0000 (17:27 +0200)
Somewhere in the conversion of the RNDIS gadget code to the new
framework, the descriptor of its data interface seems to have
been copied from the CDC Ethernet driver.  Unfortunately that
means it got a nonzero altsetting ... which is incorrect.  Issue
uncovered by Richard Röjfors <richard.rojfors@endian.se>.

This patch fixes that problem, and resolves at least some cases
of Windows XP bluescreening itself.

Tested-by: Richard Röjfors <richard.rojfors@endian.se>.
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Cc: stable <stable@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
drivers/usb/gadget/f_rndis.c

index 659b3d9..8afb14a 100644 (file)
@@ -172,7 +172,6 @@ static struct usb_interface_descriptor rndis_data_intf __initdata = {
        .bDescriptorType =      USB_DT_INTERFACE,
 
        /* .bInterfaceNumber = DYNAMIC */
-       .bAlternateSetting =    1,
        .bNumEndpoints =        2,
        .bInterfaceClass =      USB_CLASS_CDC_DATA,
        .bInterfaceSubClass =   0,