From: NeilBrown Date: Thu, 22 Dec 2011 22:57:00 +0000 (+1100) Subject: md/raid5: ensure correct assessment of drives during degraded reshape. X-Git-Tag: v3.2-rc7~8^2~2 X-Git-Url: https://git.openpandora.org/cgi-bin/gitweb.cgi?p=pandora-kernel.git;a=commitdiff_plain;h=30d7a4836847bdb10b32c78a4879d4aebe0f193b md/raid5: ensure correct assessment of drives during degraded reshape. While reshaping a degraded array (as when reshaping a RAID0 by first converting it to a degraded RAID4) we currently get confused about which devices are in_sync. In most cases we get it right, but in the region that is being reshaped we need to treat non-failed devices as in-sync when we have the data but haven't actually written it out yet. Reported-by: Adam Kwolek Signed-off-by: NeilBrown --- diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c index 31670f8d6b65..858fdbb7eb07 100644 --- a/drivers/md/raid5.c +++ b/drivers/md/raid5.c @@ -3065,11 +3065,17 @@ static void analyse_stripe(struct stripe_head *sh, struct stripe_head_state *s) } } else if (test_bit(In_sync, &rdev->flags)) set_bit(R5_Insync, &dev->flags); - else { + else if (sh->sector + STRIPE_SECTORS <= rdev->recovery_offset) /* in sync if before recovery_offset */ - if (sh->sector + STRIPE_SECTORS <= rdev->recovery_offset) - set_bit(R5_Insync, &dev->flags); - } + set_bit(R5_Insync, &dev->flags); + else if (test_bit(R5_UPTODATE, &dev->flags) && + test_bit(R5_Expanded, &dev->flags)) + /* If we've reshaped into here, we assume it is Insync. + * We will shortly update recovery_offset to make + * it official. + */ + set_bit(R5_Insync, &dev->flags); + if (rdev && test_bit(R5_WriteError, &dev->flags)) { clear_bit(R5_Insync, &dev->flags); if (!test_bit(Faulty, &rdev->flags)) {