wl1251: timeout one too soon in wl1251_boot_run_firmware()
authorRoel Kluin <roel.kluin@gmail.com>
Sat, 26 Dec 2009 19:31:59 +0000 (20:31 +0100)
committerJohn W. Linville <linville@tuxdriver.com>
Mon, 28 Dec 2009 21:20:06 +0000 (16:20 -0500)
`loop' reaches INIT_LOOP + 1 after the loop. so if ACX_INTR_INIT_COMPLETE
occurs in the last iteration the write occurs but also the error out as if a
timeout occurred. This is probably very unlikely to ever occur.

Signed-off-by: Roel Kluin <roel.kluin@gmail.com>
Acked-by: Kalle Valo <kalle.valo@nokia.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
drivers/net/wireless/wl12xx/wl1251_boot.c

index 2e733e7..28a8086 100644 (file)
@@ -256,7 +256,7 @@ int wl1251_boot_run_firmware(struct wl1251 *wl)
                }
        }
 
-       if (loop >= INIT_LOOP) {
+       if (loop > INIT_LOOP) {
                wl1251_error("timeout waiting for the hardware to "
                             "complete initialization");
                return -EIO;