Reported temperature can be also negative, so cache value in non negative
Kelvin degree.
Signed-off-by: Pali Rohár <pali.rohar@gmail.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Conflicts:
drivers/power/bq27x00_battery.c
}
/*
- * Return the battery temperature in tenths of degree Celsius
+ * Return the battery temperature in tenths of degree Kelvin
* Or < 0 if something fails.
*/
static int bq27x00_battery_read_temperature(struct bq27x00_device_info *di)
return temp;
}
- if (di->chip == BQ27500)
- temp -= 2731;
- else
- temp = ((temp * 5) - 5463) / 2;
+ if (di->chip != BQ27500)
+ temp = 5 * temp / 2;
return temp;
}
break;
case POWER_SUPPLY_PROP_TEMP:
ret = bq27x00_simple_value(di->cache.temperature, val);
+ if (ret == 0)
+ val->intval -= 2731;
break;
case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
ret = bq27x00_simple_value(di->cache.time_to_empty, val);