mmc: block: don't use CMD23 with very old MMC cards
authorDaniel Glöckner <dg@emlix.com>
Tue, 30 Aug 2016 12:17:30 +0000 (14:17 +0200)
committerBen Hutchings <ben@decadent.org.uk>
Thu, 23 Feb 2017 03:50:51 +0000 (03:50 +0000)
commit 0ed50abb2d8fc81570b53af25621dad560cd49b3 upstream.

CMD23 aka SET_BLOCK_COUNT was introduced with MMC v3.1.
Older versions of the specification allowed to terminate
multi-block transfers only with CMD12.

The patch fixes the following problem:

  mmc0: new MMC card at address 0001
  mmcblk0: mmc0:0001 SDMB-16 15.3 MiB
  mmcblk0: timed out sending SET_BLOCK_COUNT command, card status 0x400900
  ...
  blk_update_request: I/O error, dev mmcblk0, sector 0
  Buffer I/O error on dev mmcblk0, logical block 0, async page read
   mmcblk0: unable to read partition table

Signed-off-by: Daniel Glöckner <dg@emlix.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: Ben Hutchings <ben@decadent.org.uk>
drivers/mmc/card/block.c

index f53d5c8..1a3d622 100644 (file)
@@ -1493,7 +1493,8 @@ static struct mmc_blk_data *mmc_blk_alloc_req(struct mmc_card *card,
        set_capacity(md->disk, size);
 
        if (mmc_host_cmd23(card->host)) {
-               if (mmc_card_mmc(card) ||
+               if ((mmc_card_mmc(card) &&
+                    card->csd.mmca_vsn >= CSD_SPEC_VER_3) ||
                    (mmc_card_sd(card) &&
                     card->scr.cmds & SD_SCR_CMD23_SUPPORT))
                        md->flags |= MMC_BLK_CMD23;