[PATCH] libata: set PIO-0 after successful EH reset
authorTejun Heo <htejun@gmail.com>
Wed, 31 May 2006 09:27:23 +0000 (18:27 +0900)
committerTejun Heo <htejun@gmail.com>
Wed, 31 May 2006 09:27:23 +0000 (18:27 +0900)
commit20952b699035448d2277c64efc5910a31be66ed1
treea2fab9d516ce200ebc8cf72cda214ec447e0d5d9
parentef2824073fba9def3cf122e89cc485f66dd71f70
[PATCH] libata: set PIO-0 after successful EH reset

Set ata_device->pio_mode to XFER_PIO_0 after a successful reset.  This
is to keep EH resets consistent with probe resets as updated by the
commit b6079ca409bf88c248992e96510dd6f610f7ed89.  Note that, with
soon-to-follow hotplug update, EH resets will include probe resets.

Signed-off-by: Tejun Heo <htejun@gmail.com>
drivers/scsi/libata-eh.c