md/raid5: ensure correct assessment of drives during degraded reshape.
[pandora-kernel.git] / drivers / md / raid5.c
index 31670f8..858fdbb 100644 (file)
@@ -3065,11 +3065,17 @@ static void analyse_stripe(struct stripe_head *sh, struct stripe_head_state *s)
                        }
                } else if (test_bit(In_sync, &rdev->flags))
                        set_bit(R5_Insync, &dev->flags);
-               else {
+               else if (sh->sector + STRIPE_SECTORS <= rdev->recovery_offset)
                        /* in sync if before recovery_offset */
-                       if (sh->sector + STRIPE_SECTORS <= rdev->recovery_offset)
-                               set_bit(R5_Insync, &dev->flags);
-               }
+                       set_bit(R5_Insync, &dev->flags);
+               else if (test_bit(R5_UPTODATE, &dev->flags) &&
+                        test_bit(R5_Expanded, &dev->flags))
+                       /* If we've reshaped into here, we assume it is Insync.
+                        * We will shortly update recovery_offset to make
+                        * it official.
+                        */
+                       set_bit(R5_Insync, &dev->flags);
+
                if (rdev && test_bit(R5_WriteError, &dev->flags)) {
                        clear_bit(R5_Insync, &dev->flags);
                        if (!test_bit(Faulty, &rdev->flags)) {