Merge branch 'packaging' of git://git.kernel.org/pub/scm/linux/kernel/git/mmarek...
[pandora-kernel.git] / Documentation / networking / bonding.txt
1
2                 Linux Ethernet Bonding Driver HOWTO
3
4                 Latest update: 27 April 2011
5
6 Initial release : Thomas Davis <tadavis at lbl.gov>
7 Corrections, HA extensions : 2000/10/03-15 :
8   - Willy Tarreau <willy at meta-x.org>
9   - Constantine Gavrilov <const-g at xpert.com>
10   - Chad N. Tindel <ctindel at ieee dot org>
11   - Janice Girouard <girouard at us dot ibm dot com>
12   - Jay Vosburgh <fubar at us dot ibm dot com>
13
14 Reorganized and updated Feb 2005 by Jay Vosburgh
15 Added Sysfs information: 2006/04/24
16   - Mitch Williams <mitch.a.williams at intel.com>
17
18 Introduction
19 ============
20
21         The Linux bonding driver provides a method for aggregating
22 multiple network interfaces into a single logical "bonded" interface.
23 The behavior of the bonded interfaces depends upon the mode; generally
24 speaking, modes provide either hot standby or load balancing services.
25 Additionally, link integrity monitoring may be performed.
26         
27         The bonding driver originally came from Donald Becker's
28 beowulf patches for kernel 2.0. It has changed quite a bit since, and
29 the original tools from extreme-linux and beowulf sites will not work
30 with this version of the driver.
31
32         For new versions of the driver, updated userspace tools, and
33 who to ask for help, please follow the links at the end of this file.
34
35 Table of Contents
36 =================
37
38 1. Bonding Driver Installation
39
40 2. Bonding Driver Options
41
42 3. Configuring Bonding Devices
43 3.1     Configuration with Sysconfig Support
44 3.1.1           Using DHCP with Sysconfig
45 3.1.2           Configuring Multiple Bonds with Sysconfig
46 3.2     Configuration with Initscripts Support
47 3.2.1           Using DHCP with Initscripts
48 3.2.2           Configuring Multiple Bonds with Initscripts
49 3.3     Configuring Bonding Manually with Ifenslave
50 3.3.1           Configuring Multiple Bonds Manually
51 3.4     Configuring Bonding Manually via Sysfs
52 3.5     Configuration with Interfaces Support
53 3.6     Overriding Configuration for Special Cases
54
55 4. Querying Bonding Configuration
56 4.1     Bonding Configuration
57 4.2     Network Configuration
58
59 5. Switch Configuration
60
61 6. 802.1q VLAN Support
62
63 7. Link Monitoring
64 7.1     ARP Monitor Operation
65 7.2     Configuring Multiple ARP Targets
66 7.3     MII Monitor Operation
67
68 8. Potential Trouble Sources
69 8.1     Adventures in Routing
70 8.2     Ethernet Device Renaming
71 8.3     Painfully Slow Or No Failed Link Detection By Miimon
72
73 9. SNMP agents
74
75 10. Promiscuous mode
76
77 11. Configuring Bonding for High Availability
78 11.1    High Availability in a Single Switch Topology
79 11.2    High Availability in a Multiple Switch Topology
80 11.2.1          HA Bonding Mode Selection for Multiple Switch Topology
81 11.2.2          HA Link Monitoring for Multiple Switch Topology
82
83 12. Configuring Bonding for Maximum Throughput
84 12.1    Maximum Throughput in a Single Switch Topology
85 12.1.1          MT Bonding Mode Selection for Single Switch Topology
86 12.1.2          MT Link Monitoring for Single Switch Topology
87 12.2    Maximum Throughput in a Multiple Switch Topology
88 12.2.1          MT Bonding Mode Selection for Multiple Switch Topology
89 12.2.2          MT Link Monitoring for Multiple Switch Topology
90
91 13. Switch Behavior Issues
92 13.1    Link Establishment and Failover Delays
93 13.2    Duplicated Incoming Packets
94
95 14. Hardware Specific Considerations
96 14.1    IBM BladeCenter
97
98 15. Frequently Asked Questions
99
100 16. Resources and Links
101
102
103 1. Bonding Driver Installation
104 ==============================
105
106         Most popular distro kernels ship with the bonding driver
107 already available as a module and the ifenslave user level control
108 program installed and ready for use. If your distro does not, or you
109 have need to compile bonding from source (e.g., configuring and
110 installing a mainline kernel from kernel.org), you'll need to perform
111 the following steps:
112
113 1.1 Configure and build the kernel with bonding
114 -----------------------------------------------
115
116         The current version of the bonding driver is available in the
117 drivers/net/bonding subdirectory of the most recent kernel source
118 (which is available on http://kernel.org).  Most users "rolling their
119 own" will want to use the most recent kernel from kernel.org.
120
121         Configure kernel with "make menuconfig" (or "make xconfig" or
122 "make config"), then select "Bonding driver support" in the "Network
123 device support" section.  It is recommended that you configure the
124 driver as module since it is currently the only way to pass parameters
125 to the driver or configure more than one bonding device.
126
127         Build and install the new kernel and modules, then continue
128 below to install ifenslave.
129
130 1.2 Install ifenslave Control Utility
131 -------------------------------------
132
133         The ifenslave user level control program is included in the
134 kernel source tree, in the file Documentation/networking/ifenslave.c.
135 It is generally recommended that you use the ifenslave that
136 corresponds to the kernel that you are using (either from the same
137 source tree or supplied with the distro), however, ifenslave
138 executables from older kernels should function (but features newer
139 than the ifenslave release are not supported).  Running an ifenslave
140 that is newer than the kernel is not supported, and may or may not
141 work.
142
143         To install ifenslave, do the following:
144
145 # gcc -Wall -O -I/usr/src/linux/include ifenslave.c -o ifenslave
146 # cp ifenslave /sbin/ifenslave
147
148         If your kernel source is not in "/usr/src/linux," then replace
149 "/usr/src/linux/include" in the above with the location of your kernel
150 source include directory.
151
152         You may wish to back up any existing /sbin/ifenslave, or, for
153 testing or informal use, tag the ifenslave to the kernel version
154 (e.g., name the ifenslave executable /sbin/ifenslave-2.6.10).
155
156 IMPORTANT NOTE:
157
158         If you omit the "-I" or specify an incorrect directory, you
159 may end up with an ifenslave that is incompatible with the kernel
160 you're trying to build it for.  Some distros (e.g., Red Hat from 7.1
161 onwards) do not have /usr/include/linux symbolically linked to the
162 default kernel source include directory.
163
164 SECOND IMPORTANT NOTE:
165         If you plan to configure bonding using sysfs or using the
166 /etc/network/interfaces file, you do not need to use ifenslave.
167
168 2. Bonding Driver Options
169 =========================
170
171         Options for the bonding driver are supplied as parameters to the
172 bonding module at load time, or are specified via sysfs.
173
174         Module options may be given as command line arguments to the
175 insmod or modprobe command, but are usually specified in either the
176 /etc/modules.conf or /etc/modprobe.conf configuration file, or in a
177 distro-specific configuration file (some of which are detailed in the next
178 section).
179
180         Details on bonding support for sysfs is provided in the
181 "Configuring Bonding Manually via Sysfs" section, below.
182
183         The available bonding driver parameters are listed below. If a
184 parameter is not specified the default value is used.  When initially
185 configuring a bond, it is recommended "tail -f /var/log/messages" be
186 run in a separate window to watch for bonding driver error messages.
187
188         It is critical that either the miimon or arp_interval and
189 arp_ip_target parameters be specified, otherwise serious network
190 degradation will occur during link failures.  Very few devices do not
191 support at least miimon, so there is really no reason not to use it.
192
193         Options with textual values will accept either the text name
194 or, for backwards compatibility, the option value.  E.g.,
195 "mode=802.3ad" and "mode=4" set the same mode.
196
197         The parameters are as follows:
198
199 ad_select
200
201         Specifies the 802.3ad aggregation selection logic to use.  The
202         possible values and their effects are:
203
204         stable or 0
205
206                 The active aggregator is chosen by largest aggregate
207                 bandwidth.
208
209                 Reselection of the active aggregator occurs only when all
210                 slaves of the active aggregator are down or the active
211                 aggregator has no slaves.
212
213                 This is the default value.
214
215         bandwidth or 1
216
217                 The active aggregator is chosen by largest aggregate
218                 bandwidth.  Reselection occurs if:
219
220                 - A slave is added to or removed from the bond
221
222                 - Any slave's link state changes
223
224                 - Any slave's 802.3ad association state changes
225
226                 - The bond's administrative state changes to up
227
228         count or 2
229
230                 The active aggregator is chosen by the largest number of
231                 ports (slaves).  Reselection occurs as described under the
232                 "bandwidth" setting, above.
233
234         The bandwidth and count selection policies permit failover of
235         802.3ad aggregations when partial failure of the active aggregator
236         occurs.  This keeps the aggregator with the highest availability
237         (either in bandwidth or in number of ports) active at all times.
238
239         This option was added in bonding version 3.4.0.
240
241 arp_interval
242
243         Specifies the ARP link monitoring frequency in milliseconds.
244
245         The ARP monitor works by periodically checking the slave
246         devices to determine whether they have sent or received
247         traffic recently (the precise criteria depends upon the
248         bonding mode, and the state of the slave).  Regular traffic is
249         generated via ARP probes issued for the addresses specified by
250         the arp_ip_target option.
251
252         This behavior can be modified by the arp_validate option,
253         below.
254
255         If ARP monitoring is used in an etherchannel compatible mode
256         (modes 0 and 2), the switch should be configured in a mode
257         that evenly distributes packets across all links. If the
258         switch is configured to distribute the packets in an XOR
259         fashion, all replies from the ARP targets will be received on
260         the same link which could cause the other team members to
261         fail.  ARP monitoring should not be used in conjunction with
262         miimon.  A value of 0 disables ARP monitoring.  The default
263         value is 0.
264
265 arp_ip_target
266
267         Specifies the IP addresses to use as ARP monitoring peers when
268         arp_interval is > 0.  These are the targets of the ARP request
269         sent to determine the health of the link to the targets.
270         Specify these values in ddd.ddd.ddd.ddd format.  Multiple IP
271         addresses must be separated by a comma.  At least one IP
272         address must be given for ARP monitoring to function.  The
273         maximum number of targets that can be specified is 16.  The
274         default value is no IP addresses.
275
276 arp_validate
277
278         Specifies whether or not ARP probes and replies should be
279         validated in the active-backup mode.  This causes the ARP
280         monitor to examine the incoming ARP requests and replies, and
281         only consider a slave to be up if it is receiving the
282         appropriate ARP traffic.
283
284         Possible values are:
285
286         none or 0
287
288                 No validation is performed.  This is the default.
289
290         active or 1
291
292                 Validation is performed only for the active slave.
293
294         backup or 2
295
296                 Validation is performed only for backup slaves.
297
298         all or 3
299
300                 Validation is performed for all slaves.
301
302         For the active slave, the validation checks ARP replies to
303         confirm that they were generated by an arp_ip_target.  Since
304         backup slaves do not typically receive these replies, the
305         validation performed for backup slaves is on the ARP request
306         sent out via the active slave.  It is possible that some
307         switch or network configurations may result in situations
308         wherein the backup slaves do not receive the ARP requests; in
309         such a situation, validation of backup slaves must be
310         disabled.
311
312         This option is useful in network configurations in which
313         multiple bonding hosts are concurrently issuing ARPs to one or
314         more targets beyond a common switch.  Should the link between
315         the switch and target fail (but not the switch itself), the
316         probe traffic generated by the multiple bonding instances will
317         fool the standard ARP monitor into considering the links as
318         still up.  Use of the arp_validate option can resolve this, as
319         the ARP monitor will only consider ARP requests and replies
320         associated with its own instance of bonding.
321
322         This option was added in bonding version 3.1.0.
323
324 downdelay
325
326         Specifies the time, in milliseconds, to wait before disabling
327         a slave after a link failure has been detected.  This option
328         is only valid for the miimon link monitor.  The downdelay
329         value should be a multiple of the miimon value; if not, it
330         will be rounded down to the nearest multiple.  The default
331         value is 0.
332
333 fail_over_mac
334
335         Specifies whether active-backup mode should set all slaves to
336         the same MAC address at enslavement (the traditional
337         behavior), or, when enabled, perform special handling of the
338         bond's MAC address in accordance with the selected policy.
339
340         Possible values are:
341
342         none or 0
343
344                 This setting disables fail_over_mac, and causes
345                 bonding to set all slaves of an active-backup bond to
346                 the same MAC address at enslavement time.  This is the
347                 default.
348
349         active or 1
350
351                 The "active" fail_over_mac policy indicates that the
352                 MAC address of the bond should always be the MAC
353                 address of the currently active slave.  The MAC
354                 address of the slaves is not changed; instead, the MAC
355                 address of the bond changes during a failover.
356
357                 This policy is useful for devices that cannot ever
358                 alter their MAC address, or for devices that refuse
359                 incoming broadcasts with their own source MAC (which
360                 interferes with the ARP monitor).
361
362                 The down side of this policy is that every device on
363                 the network must be updated via gratuitous ARP,
364                 vs. just updating a switch or set of switches (which
365                 often takes place for any traffic, not just ARP
366                 traffic, if the switch snoops incoming traffic to
367                 update its tables) for the traditional method.  If the
368                 gratuitous ARP is lost, communication may be
369                 disrupted.
370
371                 When this policy is used in conjunction with the mii
372                 monitor, devices which assert link up prior to being
373                 able to actually transmit and receive are particularly
374                 susceptible to loss of the gratuitous ARP, and an
375                 appropriate updelay setting may be required.
376
377         follow or 2
378
379                 The "follow" fail_over_mac policy causes the MAC
380                 address of the bond to be selected normally (normally
381                 the MAC address of the first slave added to the bond).
382                 However, the second and subsequent slaves are not set
383                 to this MAC address while they are in a backup role; a
384                 slave is programmed with the bond's MAC address at
385                 failover time (and the formerly active slave receives
386                 the newly active slave's MAC address).
387
388                 This policy is useful for multiport devices that
389                 either become confused or incur a performance penalty
390                 when multiple ports are programmed with the same MAC
391                 address.
392
393
394         The default policy is none, unless the first slave cannot
395         change its MAC address, in which case the active policy is
396         selected by default.
397
398         This option may be modified via sysfs only when no slaves are
399         present in the bond.
400
401         This option was added in bonding version 3.2.0.  The "follow"
402         policy was added in bonding version 3.3.0.
403
404 lacp_rate
405
406         Option specifying the rate in which we'll ask our link partner
407         to transmit LACPDU packets in 802.3ad mode.  Possible values
408         are:
409
410         slow or 0
411                 Request partner to transmit LACPDUs every 30 seconds
412
413         fast or 1
414                 Request partner to transmit LACPDUs every 1 second
415
416         The default is slow.
417
418 max_bonds
419
420         Specifies the number of bonding devices to create for this
421         instance of the bonding driver.  E.g., if max_bonds is 3, and
422         the bonding driver is not already loaded, then bond0, bond1
423         and bond2 will be created.  The default value is 1.  Specifying
424         a value of 0 will load bonding, but will not create any devices.
425
426 miimon
427
428         Specifies the MII link monitoring frequency in milliseconds.
429         This determines how often the link state of each slave is
430         inspected for link failures.  A value of zero disables MII
431         link monitoring.  A value of 100 is a good starting point.
432         The use_carrier option, below, affects how the link state is
433         determined.  See the High Availability section for additional
434         information.  The default value is 0.
435
436 mode
437
438         Specifies one of the bonding policies. The default is
439         balance-rr (round robin).  Possible values are:
440
441         balance-rr or 0
442
443                 Round-robin policy: Transmit packets in sequential
444                 order from the first available slave through the
445                 last.  This mode provides load balancing and fault
446                 tolerance.
447
448         active-backup or 1
449
450                 Active-backup policy: Only one slave in the bond is
451                 active.  A different slave becomes active if, and only
452                 if, the active slave fails.  The bond's MAC address is
453                 externally visible on only one port (network adapter)
454                 to avoid confusing the switch.
455
456                 In bonding version 2.6.2 or later, when a failover
457                 occurs in active-backup mode, bonding will issue one
458                 or more gratuitous ARPs on the newly active slave.
459                 One gratuitous ARP is issued for the bonding master
460                 interface and each VLAN interfaces configured above
461                 it, provided that the interface has at least one IP
462                 address configured.  Gratuitous ARPs issued for VLAN
463                 interfaces are tagged with the appropriate VLAN id.
464
465                 This mode provides fault tolerance.  The primary
466                 option, documented below, affects the behavior of this
467                 mode.
468
469         balance-xor or 2
470
471                 XOR policy: Transmit based on the selected transmit
472                 hash policy.  The default policy is a simple [(source
473                 MAC address XOR'd with destination MAC address) modulo
474                 slave count].  Alternate transmit policies may be
475                 selected via the xmit_hash_policy option, described
476                 below.
477
478                 This mode provides load balancing and fault tolerance.
479
480         broadcast or 3
481
482                 Broadcast policy: transmits everything on all slave
483                 interfaces.  This mode provides fault tolerance.
484
485         802.3ad or 4
486
487                 IEEE 802.3ad Dynamic link aggregation.  Creates
488                 aggregation groups that share the same speed and
489                 duplex settings.  Utilizes all slaves in the active
490                 aggregator according to the 802.3ad specification.
491
492                 Slave selection for outgoing traffic is done according
493                 to the transmit hash policy, which may be changed from
494                 the default simple XOR policy via the xmit_hash_policy
495                 option, documented below.  Note that not all transmit
496                 policies may be 802.3ad compliant, particularly in
497                 regards to the packet mis-ordering requirements of
498                 section 43.2.4 of the 802.3ad standard.  Differing
499                 peer implementations will have varying tolerances for
500                 noncompliance.
501
502                 Prerequisites:
503
504                 1. Ethtool support in the base drivers for retrieving
505                 the speed and duplex of each slave.
506
507                 2. A switch that supports IEEE 802.3ad Dynamic link
508                 aggregation.
509
510                 Most switches will require some type of configuration
511                 to enable 802.3ad mode.
512
513         balance-tlb or 5
514
515                 Adaptive transmit load balancing: channel bonding that
516                 does not require any special switch support.  The
517                 outgoing traffic is distributed according to the
518                 current load (computed relative to the speed) on each
519                 slave.  Incoming traffic is received by the current
520                 slave.  If the receiving slave fails, another slave
521                 takes over the MAC address of the failed receiving
522                 slave.
523
524                 Prerequisite:
525
526                 Ethtool support in the base drivers for retrieving the
527                 speed of each slave.
528
529         balance-alb or 6
530
531                 Adaptive load balancing: includes balance-tlb plus
532                 receive load balancing (rlb) for IPV4 traffic, and
533                 does not require any special switch support.  The
534                 receive load balancing is achieved by ARP negotiation.
535                 The bonding driver intercepts the ARP Replies sent by
536                 the local system on their way out and overwrites the
537                 source hardware address with the unique hardware
538                 address of one of the slaves in the bond such that
539                 different peers use different hardware addresses for
540                 the server.
541
542                 Receive traffic from connections created by the server
543                 is also balanced.  When the local system sends an ARP
544                 Request the bonding driver copies and saves the peer's
545                 IP information from the ARP packet.  When the ARP
546                 Reply arrives from the peer, its hardware address is
547                 retrieved and the bonding driver initiates an ARP
548                 reply to this peer assigning it to one of the slaves
549                 in the bond.  A problematic outcome of using ARP
550                 negotiation for balancing is that each time that an
551                 ARP request is broadcast it uses the hardware address
552                 of the bond.  Hence, peers learn the hardware address
553                 of the bond and the balancing of receive traffic
554                 collapses to the current slave.  This is handled by
555                 sending updates (ARP Replies) to all the peers with
556                 their individually assigned hardware address such that
557                 the traffic is redistributed.  Receive traffic is also
558                 redistributed when a new slave is added to the bond
559                 and when an inactive slave is re-activated.  The
560                 receive load is distributed sequentially (round robin)
561                 among the group of highest speed slaves in the bond.
562
563                 When a link is reconnected or a new slave joins the
564                 bond the receive traffic is redistributed among all
565                 active slaves in the bond by initiating ARP Replies
566                 with the selected MAC address to each of the
567                 clients. The updelay parameter (detailed below) must
568                 be set to a value equal or greater than the switch's
569                 forwarding delay so that the ARP Replies sent to the
570                 peers will not be blocked by the switch.
571
572                 Prerequisites:
573
574                 1. Ethtool support in the base drivers for retrieving
575                 the speed of each slave.
576
577                 2. Base driver support for setting the hardware
578                 address of a device while it is open.  This is
579                 required so that there will always be one slave in the
580                 team using the bond hardware address (the
581                 curr_active_slave) while having a unique hardware
582                 address for each slave in the bond.  If the
583                 curr_active_slave fails its hardware address is
584                 swapped with the new curr_active_slave that was
585                 chosen.
586
587 num_grat_arp
588 num_unsol_na
589
590         Specify the number of peer notifications (gratuitous ARPs and
591         unsolicited IPv6 Neighbor Advertisements) to be issued after a
592         failover event.  As soon as the link is up on the new slave
593         (possibly immediately) a peer notification is sent on the
594         bonding device and each VLAN sub-device.  This is repeated at
595         each link monitor interval (arp_interval or miimon, whichever
596         is active) if the number is greater than 1.
597
598         The valid range is 0 - 255; the default value is 1.  These options
599         affect only the active-backup mode.  These options were added for
600         bonding versions 3.3.0 and 3.4.0 respectively.
601
602         From Linux 2.6.40 and bonding version 3.7.1, these notifications
603         are generated by the ipv4 and ipv6 code and the numbers of
604         repetitions cannot be set independently.
605
606 primary
607
608         A string (eth0, eth2, etc) specifying which slave is the
609         primary device.  The specified device will always be the
610         active slave while it is available.  Only when the primary is
611         off-line will alternate devices be used.  This is useful when
612         one slave is preferred over another, e.g., when one slave has
613         higher throughput than another.
614
615         The primary option is only valid for active-backup mode.
616
617 primary_reselect
618
619         Specifies the reselection policy for the primary slave.  This
620         affects how the primary slave is chosen to become the active slave
621         when failure of the active slave or recovery of the primary slave
622         occurs.  This option is designed to prevent flip-flopping between
623         the primary slave and other slaves.  Possible values are:
624
625         always or 0 (default)
626
627                 The primary slave becomes the active slave whenever it
628                 comes back up.
629
630         better or 1
631
632                 The primary slave becomes the active slave when it comes
633                 back up, if the speed and duplex of the primary slave is
634                 better than the speed and duplex of the current active
635                 slave.
636
637         failure or 2
638
639                 The primary slave becomes the active slave only if the
640                 current active slave fails and the primary slave is up.
641
642         The primary_reselect setting is ignored in two cases:
643
644                 If no slaves are active, the first slave to recover is
645                 made the active slave.
646
647                 When initially enslaved, the primary slave is always made
648                 the active slave.
649
650         Changing the primary_reselect policy via sysfs will cause an
651         immediate selection of the best active slave according to the new
652         policy.  This may or may not result in a change of the active
653         slave, depending upon the circumstances.
654
655         This option was added for bonding version 3.6.0.
656
657 updelay
658
659         Specifies the time, in milliseconds, to wait before enabling a
660         slave after a link recovery has been detected.  This option is
661         only valid for the miimon link monitor.  The updelay value
662         should be a multiple of the miimon value; if not, it will be
663         rounded down to the nearest multiple.  The default value is 0.
664
665 use_carrier
666
667         Specifies whether or not miimon should use MII or ETHTOOL
668         ioctls vs. netif_carrier_ok() to determine the link
669         status. The MII or ETHTOOL ioctls are less efficient and
670         utilize a deprecated calling sequence within the kernel.  The
671         netif_carrier_ok() relies on the device driver to maintain its
672         state with netif_carrier_on/off; at this writing, most, but
673         not all, device drivers support this facility.
674
675         If bonding insists that the link is up when it should not be,
676         it may be that your network device driver does not support
677         netif_carrier_on/off.  The default state for netif_carrier is
678         "carrier on," so if a driver does not support netif_carrier,
679         it will appear as if the link is always up.  In this case,
680         setting use_carrier to 0 will cause bonding to revert to the
681         MII / ETHTOOL ioctl method to determine the link state.
682
683         A value of 1 enables the use of netif_carrier_ok(), a value of
684         0 will use the deprecated MII / ETHTOOL ioctls.  The default
685         value is 1.
686
687 xmit_hash_policy
688
689         Selects the transmit hash policy to use for slave selection in
690         balance-xor and 802.3ad modes.  Possible values are:
691
692         layer2
693
694                 Uses XOR of hardware MAC addresses to generate the
695                 hash.  The formula is
696
697                 (source MAC XOR destination MAC) modulo slave count
698
699                 This algorithm will place all traffic to a particular
700                 network peer on the same slave.
701
702                 This algorithm is 802.3ad compliant.
703
704         layer2+3
705
706                 This policy uses a combination of layer2 and layer3
707                 protocol information to generate the hash.
708
709                 Uses XOR of hardware MAC addresses and IP addresses to
710                 generate the hash.  The formula is
711
712                 (((source IP XOR dest IP) AND 0xffff) XOR
713                         ( source MAC XOR destination MAC ))
714                                 modulo slave count
715
716                 This algorithm will place all traffic to a particular
717                 network peer on the same slave.  For non-IP traffic,
718                 the formula is the same as for the layer2 transmit
719                 hash policy.
720
721                 This policy is intended to provide a more balanced
722                 distribution of traffic than layer2 alone, especially
723                 in environments where a layer3 gateway device is
724                 required to reach most destinations.
725
726                 This algorithm is 802.3ad compliant.
727
728         layer3+4
729
730                 This policy uses upper layer protocol information,
731                 when available, to generate the hash.  This allows for
732                 traffic to a particular network peer to span multiple
733                 slaves, although a single connection will not span
734                 multiple slaves.
735
736                 The formula for unfragmented TCP and UDP packets is
737
738                 ((source port XOR dest port) XOR
739                          ((source IP XOR dest IP) AND 0xffff)
740                                 modulo slave count
741
742                 For fragmented TCP or UDP packets and all other IP
743                 protocol traffic, the source and destination port
744                 information is omitted.  For non-IP traffic, the
745                 formula is the same as for the layer2 transmit hash
746                 policy.
747
748                 This policy is intended to mimic the behavior of
749                 certain switches, notably Cisco switches with PFC2 as
750                 well as some Foundry and IBM products.
751
752                 This algorithm is not fully 802.3ad compliant.  A
753                 single TCP or UDP conversation containing both
754                 fragmented and unfragmented packets will see packets
755                 striped across two interfaces.  This may result in out
756                 of order delivery.  Most traffic types will not meet
757                 this criteria, as TCP rarely fragments traffic, and
758                 most UDP traffic is not involved in extended
759                 conversations.  Other implementations of 802.3ad may
760                 or may not tolerate this noncompliance.
761
762         The default value is layer2.  This option was added in bonding
763         version 2.6.3.  In earlier versions of bonding, this parameter
764         does not exist, and the layer2 policy is the only policy.  The
765         layer2+3 value was added for bonding version 3.2.2.
766
767 resend_igmp
768
769         Specifies the number of IGMP membership reports to be issued after
770         a failover event. One membership report is issued immediately after
771         the failover, subsequent packets are sent in each 200ms interval.
772
773         The valid range is 0 - 255; the default value is 1. This option
774         was added for bonding version 3.7.0.
775
776 3. Configuring Bonding Devices
777 ==============================
778
779         You can configure bonding using either your distro's network
780 initialization scripts, or manually using either ifenslave or the
781 sysfs interface.  Distros generally use one of three packages for the
782 network initialization scripts: initscripts, sysconfig or interfaces.
783 Recent versions of these packages have support for bonding, while older
784 versions do not.
785
786         We will first describe the options for configuring bonding for
787 distros using versions of initscripts, sysconfig and interfaces with full
788 or partial support for bonding, then provide information on enabling
789 bonding without support from the network initialization scripts (i.e.,
790 older versions of initscripts or sysconfig).
791
792         If you're unsure whether your distro uses sysconfig,
793 initscripts or interfaces, or don't know if it's new enough, have no fear.
794 Determining this is fairly straightforward.
795
796         First, look for a file called interfaces in /etc/network directory.
797 If this file is present in your system, then your system use interfaces. See
798 Configuration with Interfaces Support.
799
800         Else, issue the command:
801
802 $ rpm -qf /sbin/ifup
803
804         It will respond with a line of text starting with either
805 "initscripts" or "sysconfig," followed by some numbers.  This is the
806 package that provides your network initialization scripts.
807
808         Next, to determine if your installation supports bonding,
809 issue the command:
810
811 $ grep ifenslave /sbin/ifup
812
813         If this returns any matches, then your initscripts or
814 sysconfig has support for bonding.
815
816 3.1 Configuration with Sysconfig Support
817 ----------------------------------------
818
819         This section applies to distros using a version of sysconfig
820 with bonding support, for example, SuSE Linux Enterprise Server 9.
821
822         SuSE SLES 9's networking configuration system does support
823 bonding, however, at this writing, the YaST system configuration
824 front end does not provide any means to work with bonding devices.
825 Bonding devices can be managed by hand, however, as follows.
826
827         First, if they have not already been configured, configure the
828 slave devices.  On SLES 9, this is most easily done by running the
829 yast2 sysconfig configuration utility.  The goal is for to create an
830 ifcfg-id file for each slave device.  The simplest way to accomplish
831 this is to configure the devices for DHCP (this is only to get the
832 file ifcfg-id file created; see below for some issues with DHCP).  The
833 name of the configuration file for each device will be of the form:
834
835 ifcfg-id-xx:xx:xx:xx:xx:xx
836
837         Where the "xx" portion will be replaced with the digits from
838 the device's permanent MAC address.
839
840         Once the set of ifcfg-id-xx:xx:xx:xx:xx:xx files has been
841 created, it is necessary to edit the configuration files for the slave
842 devices (the MAC addresses correspond to those of the slave devices).
843 Before editing, the file will contain multiple lines, and will look
844 something like this:
845
846 BOOTPROTO='dhcp'
847 STARTMODE='on'
848 USERCTL='no'
849 UNIQUE='XNzu.WeZGOGF+4wE'
850 _nm_name='bus-pci-0001:61:01.0'
851
852         Change the BOOTPROTO and STARTMODE lines to the following:
853
854 BOOTPROTO='none'
855 STARTMODE='off'
856
857         Do not alter the UNIQUE or _nm_name lines.  Remove any other
858 lines (USERCTL, etc).
859
860         Once the ifcfg-id-xx:xx:xx:xx:xx:xx files have been modified,
861 it's time to create the configuration file for the bonding device
862 itself.  This file is named ifcfg-bondX, where X is the number of the
863 bonding device to create, starting at 0.  The first such file is
864 ifcfg-bond0, the second is ifcfg-bond1, and so on.  The sysconfig
865 network configuration system will correctly start multiple instances
866 of bonding.
867
868         The contents of the ifcfg-bondX file is as follows:
869
870 BOOTPROTO="static"
871 BROADCAST="10.0.2.255"
872 IPADDR="10.0.2.10"
873 NETMASK="255.255.0.0"
874 NETWORK="10.0.2.0"
875 REMOTE_IPADDR=""
876 STARTMODE="onboot"
877 BONDING_MASTER="yes"
878 BONDING_MODULE_OPTS="mode=active-backup miimon=100"
879 BONDING_SLAVE0="eth0"
880 BONDING_SLAVE1="bus-pci-0000:06:08.1"
881
882         Replace the sample BROADCAST, IPADDR, NETMASK and NETWORK
883 values with the appropriate values for your network.
884
885         The STARTMODE specifies when the device is brought online.
886 The possible values are:
887
888         onboot:  The device is started at boot time.  If you're not
889                  sure, this is probably what you want.
890
891         manual:  The device is started only when ifup is called
892                  manually.  Bonding devices may be configured this
893                  way if you do not wish them to start automatically
894                  at boot for some reason.
895
896         hotplug: The device is started by a hotplug event.  This is not
897                  a valid choice for a bonding device.
898
899         off or ignore: The device configuration is ignored.
900
901         The line BONDING_MASTER='yes' indicates that the device is a
902 bonding master device.  The only useful value is "yes."
903
904         The contents of BONDING_MODULE_OPTS are supplied to the
905 instance of the bonding module for this device.  Specify the options
906 for the bonding mode, link monitoring, and so on here.  Do not include
907 the max_bonds bonding parameter; this will confuse the configuration
908 system if you have multiple bonding devices.
909
910         Finally, supply one BONDING_SLAVEn="slave device" for each
911 slave.  where "n" is an increasing value, one for each slave.  The
912 "slave device" is either an interface name, e.g., "eth0", or a device
913 specifier for the network device.  The interface name is easier to
914 find, but the ethN names are subject to change at boot time if, e.g.,
915 a device early in the sequence has failed.  The device specifiers
916 (bus-pci-0000:06:08.1 in the example above) specify the physical
917 network device, and will not change unless the device's bus location
918 changes (for example, it is moved from one PCI slot to another).  The
919 example above uses one of each type for demonstration purposes; most
920 configurations will choose one or the other for all slave devices.
921
922         When all configuration files have been modified or created,
923 networking must be restarted for the configuration changes to take
924 effect.  This can be accomplished via the following:
925
926 # /etc/init.d/network restart
927
928         Note that the network control script (/sbin/ifdown) will
929 remove the bonding module as part of the network shutdown processing,
930 so it is not necessary to remove the module by hand if, e.g., the
931 module parameters have changed.
932
933         Also, at this writing, YaST/YaST2 will not manage bonding
934 devices (they do not show bonding interfaces on its list of network
935 devices).  It is necessary to edit the configuration file by hand to
936 change the bonding configuration.
937
938         Additional general options and details of the ifcfg file
939 format can be found in an example ifcfg template file:
940
941 /etc/sysconfig/network/ifcfg.template
942
943         Note that the template does not document the various BONDING_
944 settings described above, but does describe many of the other options.
945
946 3.1.1 Using DHCP with Sysconfig
947 -------------------------------
948
949         Under sysconfig, configuring a device with BOOTPROTO='dhcp'
950 will cause it to query DHCP for its IP address information.  At this
951 writing, this does not function for bonding devices; the scripts
952 attempt to obtain the device address from DHCP prior to adding any of
953 the slave devices.  Without active slaves, the DHCP requests are not
954 sent to the network.
955
956 3.1.2 Configuring Multiple Bonds with Sysconfig
957 -----------------------------------------------
958
959         The sysconfig network initialization system is capable of
960 handling multiple bonding devices.  All that is necessary is for each
961 bonding instance to have an appropriately configured ifcfg-bondX file
962 (as described above).  Do not specify the "max_bonds" parameter to any
963 instance of bonding, as this will confuse sysconfig.  If you require
964 multiple bonding devices with identical parameters, create multiple
965 ifcfg-bondX files.
966
967         Because the sysconfig scripts supply the bonding module
968 options in the ifcfg-bondX file, it is not necessary to add them to
969 the system /etc/modules.conf or /etc/modprobe.conf configuration file.
970
971 3.2 Configuration with Initscripts Support
972 ------------------------------------------
973
974         This section applies to distros using a recent version of
975 initscripts with bonding support, for example, Red Hat Enterprise Linux
976 version 3 or later, Fedora, etc.  On these systems, the network
977 initialization scripts have knowledge of bonding, and can be configured to
978 control bonding devices.  Note that older versions of the initscripts
979 package have lower levels of support for bonding; this will be noted where
980 applicable.
981
982         These distros will not automatically load the network adapter
983 driver unless the ethX device is configured with an IP address.
984 Because of this constraint, users must manually configure a
985 network-script file for all physical adapters that will be members of
986 a bondX link.  Network script files are located in the directory:
987
988 /etc/sysconfig/network-scripts
989
990         The file name must be prefixed with "ifcfg-eth" and suffixed
991 with the adapter's physical adapter number.  For example, the script
992 for eth0 would be named /etc/sysconfig/network-scripts/ifcfg-eth0.
993 Place the following text in the file:
994
995 DEVICE=eth0
996 USERCTL=no
997 ONBOOT=yes
998 MASTER=bond0
999 SLAVE=yes
1000 BOOTPROTO=none
1001
1002         The DEVICE= line will be different for every ethX device and
1003 must correspond with the name of the file, i.e., ifcfg-eth1 must have
1004 a device line of DEVICE=eth1.  The setting of the MASTER= line will
1005 also depend on the final bonding interface name chosen for your bond.
1006 As with other network devices, these typically start at 0, and go up
1007 one for each device, i.e., the first bonding instance is bond0, the
1008 second is bond1, and so on.
1009
1010         Next, create a bond network script.  The file name for this
1011 script will be /etc/sysconfig/network-scripts/ifcfg-bondX where X is
1012 the number of the bond.  For bond0 the file is named "ifcfg-bond0",
1013 for bond1 it is named "ifcfg-bond1", and so on.  Within that file,
1014 place the following text:
1015
1016 DEVICE=bond0
1017 IPADDR=192.168.1.1
1018 NETMASK=255.255.255.0
1019 NETWORK=192.168.1.0
1020 BROADCAST=192.168.1.255
1021 ONBOOT=yes
1022 BOOTPROTO=none
1023 USERCTL=no
1024
1025         Be sure to change the networking specific lines (IPADDR,
1026 NETMASK, NETWORK and BROADCAST) to match your network configuration.
1027
1028         For later versions of initscripts, such as that found with Fedora
1029 7 (or later) and Red Hat Enterprise Linux version 5 (or later), it is possible,
1030 and, indeed, preferable, to specify the bonding options in the ifcfg-bond0
1031 file, e.g. a line of the format:
1032
1033 BONDING_OPTS="mode=active-backup arp_interval=60 arp_ip_target=192.168.1.254"
1034
1035         will configure the bond with the specified options.  The options
1036 specified in BONDING_OPTS are identical to the bonding module parameters
1037 except for the arp_ip_target field when using versions of initscripts older
1038 than and 8.57 (Fedora 8) and 8.45.19 (Red Hat Enterprise Linux 5.2).  When
1039 using older versions each target should be included as a separate option and
1040 should be preceded by a '+' to indicate it should be added to the list of
1041 queried targets, e.g.,
1042
1043         arp_ip_target=+192.168.1.1 arp_ip_target=+192.168.1.2
1044
1045         is the proper syntax to specify multiple targets.  When specifying
1046 options via BONDING_OPTS, it is not necessary to edit /etc/modules.conf or
1047 /etc/modprobe.conf.
1048
1049         For even older versions of initscripts that do not support
1050 BONDING_OPTS, it is necessary to edit /etc/modules.conf (or
1051 /etc/modprobe.conf, depending upon your distro) to load the bonding module
1052 with your desired options when the bond0 interface is brought up.  The
1053 following lines in /etc/modules.conf (or modprobe.conf) will load the
1054 bonding module, and select its options:
1055
1056 alias bond0 bonding
1057 options bond0 mode=balance-alb miimon=100
1058
1059         Replace the sample parameters with the appropriate set of
1060 options for your configuration.
1061
1062         Finally run "/etc/rc.d/init.d/network restart" as root.  This
1063 will restart the networking subsystem and your bond link should be now
1064 up and running.
1065
1066 3.2.1 Using DHCP with Initscripts
1067 ---------------------------------
1068
1069         Recent versions of initscripts (the versions supplied with Fedora
1070 Core 3 and Red Hat Enterprise Linux 4, or later versions, are reported to
1071 work) have support for assigning IP information to bonding devices via
1072 DHCP.
1073
1074         To configure bonding for DHCP, configure it as described
1075 above, except replace the line "BOOTPROTO=none" with "BOOTPROTO=dhcp"
1076 and add a line consisting of "TYPE=Bonding".  Note that the TYPE value
1077 is case sensitive.
1078
1079 3.2.2 Configuring Multiple Bonds with Initscripts
1080 -------------------------------------------------
1081
1082         Initscripts packages that are included with Fedora 7 and Red Hat
1083 Enterprise Linux 5 support multiple bonding interfaces by simply
1084 specifying the appropriate BONDING_OPTS= in ifcfg-bondX where X is the
1085 number of the bond.  This support requires sysfs support in the kernel,
1086 and a bonding driver of version 3.0.0 or later.  Other configurations may
1087 not support this method for specifying multiple bonding interfaces; for
1088 those instances, see the "Configuring Multiple Bonds Manually" section,
1089 below.
1090
1091 3.3 Configuring Bonding Manually with Ifenslave
1092 -----------------------------------------------
1093
1094         This section applies to distros whose network initialization
1095 scripts (the sysconfig or initscripts package) do not have specific
1096 knowledge of bonding.  One such distro is SuSE Linux Enterprise Server
1097 version 8.
1098
1099         The general method for these systems is to place the bonding
1100 module parameters into /etc/modules.conf or /etc/modprobe.conf (as
1101 appropriate for the installed distro), then add modprobe and/or
1102 ifenslave commands to the system's global init script.  The name of
1103 the global init script differs; for sysconfig, it is
1104 /etc/init.d/boot.local and for initscripts it is /etc/rc.d/rc.local.
1105
1106         For example, if you wanted to make a simple bond of two e100
1107 devices (presumed to be eth0 and eth1), and have it persist across
1108 reboots, edit the appropriate file (/etc/init.d/boot.local or
1109 /etc/rc.d/rc.local), and add the following:
1110
1111 modprobe bonding mode=balance-alb miimon=100
1112 modprobe e100
1113 ifconfig bond0 192.168.1.1 netmask 255.255.255.0 up
1114 ifenslave bond0 eth0
1115 ifenslave bond0 eth1
1116
1117         Replace the example bonding module parameters and bond0
1118 network configuration (IP address, netmask, etc) with the appropriate
1119 values for your configuration.
1120
1121         Unfortunately, this method will not provide support for the
1122 ifup and ifdown scripts on the bond devices.  To reload the bonding
1123 configuration, it is necessary to run the initialization script, e.g.,
1124
1125 # /etc/init.d/boot.local
1126
1127         or
1128
1129 # /etc/rc.d/rc.local
1130
1131         It may be desirable in such a case to create a separate script
1132 which only initializes the bonding configuration, then call that
1133 separate script from within boot.local.  This allows for bonding to be
1134 enabled without re-running the entire global init script.
1135
1136         To shut down the bonding devices, it is necessary to first
1137 mark the bonding device itself as being down, then remove the
1138 appropriate device driver modules.  For our example above, you can do
1139 the following:
1140
1141 # ifconfig bond0 down
1142 # rmmod bonding
1143 # rmmod e100
1144
1145         Again, for convenience, it may be desirable to create a script
1146 with these commands.
1147
1148
1149 3.3.1 Configuring Multiple Bonds Manually
1150 -----------------------------------------
1151
1152         This section contains information on configuring multiple
1153 bonding devices with differing options for those systems whose network
1154 initialization scripts lack support for configuring multiple bonds.
1155
1156         If you require multiple bonding devices, but all with the same
1157 options, you may wish to use the "max_bonds" module parameter,
1158 documented above.
1159
1160         To create multiple bonding devices with differing options, it is
1161 preferrable to use bonding parameters exported by sysfs, documented in the
1162 section below.
1163
1164         For versions of bonding without sysfs support, the only means to
1165 provide multiple instances of bonding with differing options is to load
1166 the bonding driver multiple times.  Note that current versions of the
1167 sysconfig network initialization scripts handle this automatically; if
1168 your distro uses these scripts, no special action is needed.  See the
1169 section Configuring Bonding Devices, above, if you're not sure about your
1170 network initialization scripts.
1171
1172         To load multiple instances of the module, it is necessary to
1173 specify a different name for each instance (the module loading system
1174 requires that every loaded module, even multiple instances of the same
1175 module, have a unique name).  This is accomplished by supplying multiple
1176 sets of bonding options in /etc/modprobe.conf, for example:
1177
1178 alias bond0 bonding
1179 options bond0 -o bond0 mode=balance-rr miimon=100
1180
1181 alias bond1 bonding
1182 options bond1 -o bond1 mode=balance-alb miimon=50
1183
1184         will load the bonding module two times.  The first instance is
1185 named "bond0" and creates the bond0 device in balance-rr mode with an
1186 miimon of 100.  The second instance is named "bond1" and creates the
1187 bond1 device in balance-alb mode with an miimon of 50.
1188
1189         In some circumstances (typically with older distributions),
1190 the above does not work, and the second bonding instance never sees
1191 its options.  In that case, the second options line can be substituted
1192 as follows:
1193
1194 install bond1 /sbin/modprobe --ignore-install bonding -o bond1 \
1195         mode=balance-alb miimon=50
1196
1197         This may be repeated any number of times, specifying a new and
1198 unique name in place of bond1 for each subsequent instance.
1199
1200         It has been observed that some Red Hat supplied kernels are unable
1201 to rename modules at load time (the "-o bond1" part).  Attempts to pass
1202 that option to modprobe will produce an "Operation not permitted" error.
1203 This has been reported on some Fedora Core kernels, and has been seen on
1204 RHEL 4 as well.  On kernels exhibiting this problem, it will be impossible
1205 to configure multiple bonds with differing parameters (as they are older
1206 kernels, and also lack sysfs support).
1207
1208 3.4 Configuring Bonding Manually via Sysfs
1209 ------------------------------------------
1210
1211         Starting with version 3.0.0, Channel Bonding may be configured
1212 via the sysfs interface.  This interface allows dynamic configuration
1213 of all bonds in the system without unloading the module.  It also
1214 allows for adding and removing bonds at runtime.  Ifenslave is no
1215 longer required, though it is still supported.
1216
1217         Use of the sysfs interface allows you to use multiple bonds
1218 with different configurations without having to reload the module.
1219 It also allows you to use multiple, differently configured bonds when
1220 bonding is compiled into the kernel.
1221
1222         You must have the sysfs filesystem mounted to configure
1223 bonding this way.  The examples in this document assume that you
1224 are using the standard mount point for sysfs, e.g. /sys.  If your
1225 sysfs filesystem is mounted elsewhere, you will need to adjust the
1226 example paths accordingly.
1227
1228 Creating and Destroying Bonds
1229 -----------------------------
1230 To add a new bond foo:
1231 # echo +foo > /sys/class/net/bonding_masters
1232
1233 To remove an existing bond bar:
1234 # echo -bar > /sys/class/net/bonding_masters
1235
1236 To show all existing bonds:
1237 # cat /sys/class/net/bonding_masters
1238
1239 NOTE: due to 4K size limitation of sysfs files, this list may be
1240 truncated if you have more than a few hundred bonds.  This is unlikely
1241 to occur under normal operating conditions.
1242
1243 Adding and Removing Slaves
1244 --------------------------
1245         Interfaces may be enslaved to a bond using the file
1246 /sys/class/net/<bond>/bonding/slaves.  The semantics for this file
1247 are the same as for the bonding_masters file.
1248
1249 To enslave interface eth0 to bond bond0:
1250 # ifconfig bond0 up
1251 # echo +eth0 > /sys/class/net/bond0/bonding/slaves
1252
1253 To free slave eth0 from bond bond0:
1254 # echo -eth0 > /sys/class/net/bond0/bonding/slaves
1255
1256         When an interface is enslaved to a bond, symlinks between the
1257 two are created in the sysfs filesystem.  In this case, you would get
1258 /sys/class/net/bond0/slave_eth0 pointing to /sys/class/net/eth0, and
1259 /sys/class/net/eth0/master pointing to /sys/class/net/bond0.
1260
1261         This means that you can tell quickly whether or not an
1262 interface is enslaved by looking for the master symlink.  Thus:
1263 # echo -eth0 > /sys/class/net/eth0/master/bonding/slaves
1264 will free eth0 from whatever bond it is enslaved to, regardless of
1265 the name of the bond interface.
1266
1267 Changing a Bond's Configuration
1268 -------------------------------
1269         Each bond may be configured individually by manipulating the
1270 files located in /sys/class/net/<bond name>/bonding
1271
1272         The names of these files correspond directly with the command-
1273 line parameters described elsewhere in this file, and, with the
1274 exception of arp_ip_target, they accept the same values.  To see the
1275 current setting, simply cat the appropriate file.
1276
1277         A few examples will be given here; for specific usage
1278 guidelines for each parameter, see the appropriate section in this
1279 document.
1280
1281 To configure bond0 for balance-alb mode:
1282 # ifconfig bond0 down
1283 # echo 6 > /sys/class/net/bond0/bonding/mode
1284  - or -
1285 # echo balance-alb > /sys/class/net/bond0/bonding/mode
1286         NOTE: The bond interface must be down before the mode can be
1287 changed.
1288
1289 To enable MII monitoring on bond0 with a 1 second interval:
1290 # echo 1000 > /sys/class/net/bond0/bonding/miimon
1291         NOTE: If ARP monitoring is enabled, it will disabled when MII
1292 monitoring is enabled, and vice-versa.
1293
1294 To add ARP targets:
1295 # echo +192.168.0.100 > /sys/class/net/bond0/bonding/arp_ip_target
1296 # echo +192.168.0.101 > /sys/class/net/bond0/bonding/arp_ip_target
1297         NOTE:  up to 16 target addresses may be specified.
1298
1299 To remove an ARP target:
1300 # echo -192.168.0.100 > /sys/class/net/bond0/bonding/arp_ip_target
1301
1302 Example Configuration
1303 ---------------------
1304         We begin with the same example that is shown in section 3.3,
1305 executed with sysfs, and without using ifenslave.
1306
1307         To make a simple bond of two e100 devices (presumed to be eth0
1308 and eth1), and have it persist across reboots, edit the appropriate
1309 file (/etc/init.d/boot.local or /etc/rc.d/rc.local), and add the
1310 following:
1311
1312 modprobe bonding
1313 modprobe e100
1314 echo balance-alb > /sys/class/net/bond0/bonding/mode
1315 ifconfig bond0 192.168.1.1 netmask 255.255.255.0 up
1316 echo 100 > /sys/class/net/bond0/bonding/miimon
1317 echo +eth0 > /sys/class/net/bond0/bonding/slaves
1318 echo +eth1 > /sys/class/net/bond0/bonding/slaves
1319
1320         To add a second bond, with two e1000 interfaces in
1321 active-backup mode, using ARP monitoring, add the following lines to
1322 your init script:
1323
1324 modprobe e1000
1325 echo +bond1 > /sys/class/net/bonding_masters
1326 echo active-backup > /sys/class/net/bond1/bonding/mode
1327 ifconfig bond1 192.168.2.1 netmask 255.255.255.0 up
1328 echo +192.168.2.100 /sys/class/net/bond1/bonding/arp_ip_target
1329 echo 2000 > /sys/class/net/bond1/bonding/arp_interval
1330 echo +eth2 > /sys/class/net/bond1/bonding/slaves
1331 echo +eth3 > /sys/class/net/bond1/bonding/slaves
1332
1333 3.5 Configuration with Interfaces Support
1334 -----------------------------------------
1335
1336         This section applies to distros which use /etc/network/interfaces file
1337 to describe network interface configuration, most notably Debian and it's
1338 derivatives.
1339
1340         The ifup and ifdown commands on Debian don't support bonding out of
1341 the box. The ifenslave-2.6 package should be installed to provide bonding
1342 support.  Once installed, this package will provide bond-* options to be used
1343 into /etc/network/interfaces.
1344
1345         Note that ifenslave-2.6 package will load the bonding module and use
1346 the ifenslave command when appropriate.
1347
1348 Example Configurations
1349 ----------------------
1350
1351 In /etc/network/interfaces, the following stanza will configure bond0, in
1352 active-backup mode, with eth0 and eth1 as slaves.
1353
1354 auto bond0
1355 iface bond0 inet dhcp
1356         bond-slaves eth0 eth1
1357         bond-mode active-backup
1358         bond-miimon 100
1359         bond-primary eth0 eth1
1360
1361 If the above configuration doesn't work, you might have a system using
1362 upstart for system startup. This is most notably true for recent
1363 Ubuntu versions. The following stanza in /etc/network/interfaces will
1364 produce the same result on those systems.
1365
1366 auto bond0
1367 iface bond0 inet dhcp
1368         bond-slaves none
1369         bond-mode active-backup
1370         bond-miimon 100
1371
1372 auto eth0
1373 iface eth0 inet manual
1374         bond-master bond0
1375         bond-primary eth0 eth1
1376
1377 auto eth1
1378 iface eth1 inet manual
1379         bond-master bond0
1380         bond-primary eth0 eth1
1381
1382 For a full list of bond-* supported options in /etc/network/interfaces and some
1383 more advanced examples tailored to you particular distros, see the files in
1384 /usr/share/doc/ifenslave-2.6.
1385
1386 3.6 Overriding Configuration for Special Cases
1387 ----------------------------------------------
1388
1389 When using the bonding driver, the physical port which transmits a frame is
1390 typically selected by the bonding driver, and is not relevant to the user or
1391 system administrator.  The output port is simply selected using the policies of
1392 the selected bonding mode.  On occasion however, it is helpful to direct certain
1393 classes of traffic to certain physical interfaces on output to implement
1394 slightly more complex policies.  For example, to reach a web server over a
1395 bonded interface in which eth0 connects to a private network, while eth1
1396 connects via a public network, it may be desirous to bias the bond to send said
1397 traffic over eth0 first, using eth1 only as a fall back, while all other traffic
1398 can safely be sent over either interface.  Such configurations may be achieved
1399 using the traffic control utilities inherent in linux.
1400
1401 By default the bonding driver is multiqueue aware and 16 queues are created
1402 when the driver initializes (see Documentation/networking/multiqueue.txt
1403 for details).  If more or less queues are desired the module parameter
1404 tx_queues can be used to change this value.  There is no sysfs parameter
1405 available as the allocation is done at module init time.
1406
1407 The output of the file /proc/net/bonding/bondX has changed so the output Queue
1408 ID is now printed for each slave:
1409
1410 Bonding Mode: fault-tolerance (active-backup)
1411 Primary Slave: None
1412 Currently Active Slave: eth0
1413 MII Status: up
1414 MII Polling Interval (ms): 0
1415 Up Delay (ms): 0
1416 Down Delay (ms): 0
1417
1418 Slave Interface: eth0
1419 MII Status: up
1420 Link Failure Count: 0
1421 Permanent HW addr: 00:1a:a0:12:8f:cb
1422 Slave queue ID: 0
1423
1424 Slave Interface: eth1
1425 MII Status: up
1426 Link Failure Count: 0
1427 Permanent HW addr: 00:1a:a0:12:8f:cc
1428 Slave queue ID: 2
1429
1430 The queue_id for a slave can be set using the command:
1431
1432 # echo "eth1:2" > /sys/class/net/bond0/bonding/queue_id
1433
1434 Any interface that needs a queue_id set should set it with multiple calls
1435 like the one above until proper priorities are set for all interfaces.  On
1436 distributions that allow configuration via initscripts, multiple 'queue_id'
1437 arguments can be added to BONDING_OPTS to set all needed slave queues.
1438
1439 These queue id's can be used in conjunction with the tc utility to configure
1440 a multiqueue qdisc and filters to bias certain traffic to transmit on certain
1441 slave devices.  For instance, say we wanted, in the above configuration to
1442 force all traffic bound to 192.168.1.100 to use eth1 in the bond as its output
1443 device. The following commands would accomplish this:
1444
1445 # tc qdisc add dev bond0 handle 1 root multiq
1446
1447 # tc filter add dev bond0 protocol ip parent 1: prio 1 u32 match ip dst \
1448         192.168.1.100 action skbedit queue_mapping 2
1449
1450 These commands tell the kernel to attach a multiqueue queue discipline to the
1451 bond0 interface and filter traffic enqueued to it, such that packets with a dst
1452 ip of 192.168.1.100 have their output queue mapping value overwritten to 2.
1453 This value is then passed into the driver, causing the normal output path
1454 selection policy to be overridden, selecting instead qid 2, which maps to eth1.
1455
1456 Note that qid values begin at 1.  Qid 0 is reserved to initiate to the driver
1457 that normal output policy selection should take place.  One benefit to simply
1458 leaving the qid for a slave to 0 is the multiqueue awareness in the bonding
1459 driver that is now present.  This awareness allows tc filters to be placed on
1460 slave devices as well as bond devices and the bonding driver will simply act as
1461 a pass-through for selecting output queues on the slave device rather than 
1462 output port selection.
1463
1464 This feature first appeared in bonding driver version 3.7.0 and support for
1465 output slave selection was limited to round-robin and active-backup modes.
1466
1467 4 Querying Bonding Configuration
1468 =================================
1469
1470 4.1 Bonding Configuration
1471 -------------------------
1472
1473         Each bonding device has a read-only file residing in the
1474 /proc/net/bonding directory.  The file contents include information
1475 about the bonding configuration, options and state of each slave.
1476
1477         For example, the contents of /proc/net/bonding/bond0 after the
1478 driver is loaded with parameters of mode=0 and miimon=1000 is
1479 generally as follows:
1480
1481         Ethernet Channel Bonding Driver: 2.6.1 (October 29, 2004)
1482         Bonding Mode: load balancing (round-robin)
1483         Currently Active Slave: eth0
1484         MII Status: up
1485         MII Polling Interval (ms): 1000
1486         Up Delay (ms): 0
1487         Down Delay (ms): 0
1488
1489         Slave Interface: eth1
1490         MII Status: up
1491         Link Failure Count: 1
1492
1493         Slave Interface: eth0
1494         MII Status: up
1495         Link Failure Count: 1
1496
1497         The precise format and contents will change depending upon the
1498 bonding configuration, state, and version of the bonding driver.
1499
1500 4.2 Network configuration
1501 -------------------------
1502
1503         The network configuration can be inspected using the ifconfig
1504 command.  Bonding devices will have the MASTER flag set; Bonding slave
1505 devices will have the SLAVE flag set.  The ifconfig output does not
1506 contain information on which slaves are associated with which masters.
1507
1508         In the example below, the bond0 interface is the master
1509 (MASTER) while eth0 and eth1 are slaves (SLAVE). Notice all slaves of
1510 bond0 have the same MAC address (HWaddr) as bond0 for all modes except
1511 TLB and ALB that require a unique MAC address for each slave.
1512
1513 # /sbin/ifconfig
1514 bond0     Link encap:Ethernet  HWaddr 00:C0:F0:1F:37:B4
1515           inet addr:XXX.XXX.XXX.YYY  Bcast:XXX.XXX.XXX.255  Mask:255.255.252.0
1516           UP BROADCAST RUNNING MASTER MULTICAST  MTU:1500  Metric:1
1517           RX packets:7224794 errors:0 dropped:0 overruns:0 frame:0
1518           TX packets:3286647 errors:1 dropped:0 overruns:1 carrier:0
1519           collisions:0 txqueuelen:0
1520
1521 eth0      Link encap:Ethernet  HWaddr 00:C0:F0:1F:37:B4
1522           UP BROADCAST RUNNING SLAVE MULTICAST  MTU:1500  Metric:1
1523           RX packets:3573025 errors:0 dropped:0 overruns:0 frame:0
1524           TX packets:1643167 errors:1 dropped:0 overruns:1 carrier:0
1525           collisions:0 txqueuelen:100
1526           Interrupt:10 Base address:0x1080
1527
1528 eth1      Link encap:Ethernet  HWaddr 00:C0:F0:1F:37:B4
1529           UP BROADCAST RUNNING SLAVE MULTICAST  MTU:1500  Metric:1
1530           RX packets:3651769 errors:0 dropped:0 overruns:0 frame:0
1531           TX packets:1643480 errors:0 dropped:0 overruns:0 carrier:0
1532           collisions:0 txqueuelen:100
1533           Interrupt:9 Base address:0x1400
1534
1535 5. Switch Configuration
1536 =======================
1537
1538         For this section, "switch" refers to whatever system the
1539 bonded devices are directly connected to (i.e., where the other end of
1540 the cable plugs into).  This may be an actual dedicated switch device,
1541 or it may be another regular system (e.g., another computer running
1542 Linux),
1543
1544         The active-backup, balance-tlb and balance-alb modes do not
1545 require any specific configuration of the switch.
1546
1547         The 802.3ad mode requires that the switch have the appropriate
1548 ports configured as an 802.3ad aggregation.  The precise method used
1549 to configure this varies from switch to switch, but, for example, a
1550 Cisco 3550 series switch requires that the appropriate ports first be
1551 grouped together in a single etherchannel instance, then that
1552 etherchannel is set to mode "lacp" to enable 802.3ad (instead of
1553 standard EtherChannel).
1554
1555         The balance-rr, balance-xor and broadcast modes generally
1556 require that the switch have the appropriate ports grouped together.
1557 The nomenclature for such a group differs between switches, it may be
1558 called an "etherchannel" (as in the Cisco example, above), a "trunk
1559 group" or some other similar variation.  For these modes, each switch
1560 will also have its own configuration options for the switch's transmit
1561 policy to the bond.  Typical choices include XOR of either the MAC or
1562 IP addresses.  The transmit policy of the two peers does not need to
1563 match.  For these three modes, the bonding mode really selects a
1564 transmit policy for an EtherChannel group; all three will interoperate
1565 with another EtherChannel group.
1566
1567
1568 6. 802.1q VLAN Support
1569 ======================
1570
1571         It is possible to configure VLAN devices over a bond interface
1572 using the 8021q driver.  However, only packets coming from the 8021q
1573 driver and passing through bonding will be tagged by default.  Self
1574 generated packets, for example, bonding's learning packets or ARP
1575 packets generated by either ALB mode or the ARP monitor mechanism, are
1576 tagged internally by bonding itself.  As a result, bonding must
1577 "learn" the VLAN IDs configured above it, and use those IDs to tag
1578 self generated packets.
1579
1580         For reasons of simplicity, and to support the use of adapters
1581 that can do VLAN hardware acceleration offloading, the bonding
1582 interface declares itself as fully hardware offloading capable, it gets
1583 the add_vid/kill_vid notifications to gather the necessary
1584 information, and it propagates those actions to the slaves.  In case
1585 of mixed adapter types, hardware accelerated tagged packets that
1586 should go through an adapter that is not offloading capable are
1587 "un-accelerated" by the bonding driver so the VLAN tag sits in the
1588 regular location.
1589
1590         VLAN interfaces *must* be added on top of a bonding interface
1591 only after enslaving at least one slave.  The bonding interface has a
1592 hardware address of 00:00:00:00:00:00 until the first slave is added.
1593 If the VLAN interface is created prior to the first enslavement, it
1594 would pick up the all-zeroes hardware address.  Once the first slave
1595 is attached to the bond, the bond device itself will pick up the
1596 slave's hardware address, which is then available for the VLAN device.
1597
1598         Also, be aware that a similar problem can occur if all slaves
1599 are released from a bond that still has one or more VLAN interfaces on
1600 top of it.  When a new slave is added, the bonding interface will
1601 obtain its hardware address from the first slave, which might not
1602 match the hardware address of the VLAN interfaces (which was
1603 ultimately copied from an earlier slave).
1604
1605         There are two methods to insure that the VLAN device operates
1606 with the correct hardware address if all slaves are removed from a
1607 bond interface:
1608
1609         1. Remove all VLAN interfaces then recreate them
1610
1611         2. Set the bonding interface's hardware address so that it
1612 matches the hardware address of the VLAN interfaces.
1613
1614         Note that changing a VLAN interface's HW address would set the
1615 underlying device -- i.e. the bonding interface -- to promiscuous
1616 mode, which might not be what you want.
1617
1618
1619 7. Link Monitoring
1620 ==================
1621
1622         The bonding driver at present supports two schemes for
1623 monitoring a slave device's link state: the ARP monitor and the MII
1624 monitor.
1625
1626         At the present time, due to implementation restrictions in the
1627 bonding driver itself, it is not possible to enable both ARP and MII
1628 monitoring simultaneously.
1629
1630 7.1 ARP Monitor Operation
1631 -------------------------
1632
1633         The ARP monitor operates as its name suggests: it sends ARP
1634 queries to one or more designated peer systems on the network, and
1635 uses the response as an indication that the link is operating.  This
1636 gives some assurance that traffic is actually flowing to and from one
1637 or more peers on the local network.
1638
1639         The ARP monitor relies on the device driver itself to verify
1640 that traffic is flowing.  In particular, the driver must keep up to
1641 date the last receive time, dev->last_rx, and transmit start time,
1642 dev->trans_start.  If these are not updated by the driver, then the
1643 ARP monitor will immediately fail any slaves using that driver, and
1644 those slaves will stay down.  If networking monitoring (tcpdump, etc)
1645 shows the ARP requests and replies on the network, then it may be that
1646 your device driver is not updating last_rx and trans_start.
1647
1648 7.2 Configuring Multiple ARP Targets
1649 ------------------------------------
1650
1651         While ARP monitoring can be done with just one target, it can
1652 be useful in a High Availability setup to have several targets to
1653 monitor.  In the case of just one target, the target itself may go
1654 down or have a problem making it unresponsive to ARP requests.  Having
1655 an additional target (or several) increases the reliability of the ARP
1656 monitoring.
1657
1658         Multiple ARP targets must be separated by commas as follows:
1659
1660 # example options for ARP monitoring with three targets
1661 alias bond0 bonding
1662 options bond0 arp_interval=60 arp_ip_target=192.168.0.1,192.168.0.3,192.168.0.9
1663
1664         For just a single target the options would resemble:
1665
1666 # example options for ARP monitoring with one target
1667 alias bond0 bonding
1668 options bond0 arp_interval=60 arp_ip_target=192.168.0.100
1669
1670
1671 7.3 MII Monitor Operation
1672 -------------------------
1673
1674         The MII monitor monitors only the carrier state of the local
1675 network interface.  It accomplishes this in one of three ways: by
1676 depending upon the device driver to maintain its carrier state, by
1677 querying the device's MII registers, or by making an ethtool query to
1678 the device.
1679
1680         If the use_carrier module parameter is 1 (the default value),
1681 then the MII monitor will rely on the driver for carrier state
1682 information (via the netif_carrier subsystem).  As explained in the
1683 use_carrier parameter information, above, if the MII monitor fails to
1684 detect carrier loss on the device (e.g., when the cable is physically
1685 disconnected), it may be that the driver does not support
1686 netif_carrier.
1687
1688         If use_carrier is 0, then the MII monitor will first query the
1689 device's (via ioctl) MII registers and check the link state.  If that
1690 request fails (not just that it returns carrier down), then the MII
1691 monitor will make an ethtool ETHOOL_GLINK request to attempt to obtain
1692 the same information.  If both methods fail (i.e., the driver either
1693 does not support or had some error in processing both the MII register
1694 and ethtool requests), then the MII monitor will assume the link is
1695 up.
1696
1697 8. Potential Sources of Trouble
1698 ===============================
1699
1700 8.1 Adventures in Routing
1701 -------------------------
1702
1703         When bonding is configured, it is important that the slave
1704 devices not have routes that supersede routes of the master (or,
1705 generally, not have routes at all).  For example, suppose the bonding
1706 device bond0 has two slaves, eth0 and eth1, and the routing table is
1707 as follows:
1708
1709 Kernel IP routing table
1710 Destination     Gateway         Genmask         Flags   MSS Window  irtt Iface
1711 10.0.0.0        0.0.0.0         255.255.0.0     U        40 0          0 eth0
1712 10.0.0.0        0.0.0.0         255.255.0.0     U        40 0          0 eth1
1713 10.0.0.0        0.0.0.0         255.255.0.0     U        40 0          0 bond0
1714 127.0.0.0       0.0.0.0         255.0.0.0       U        40 0          0 lo
1715
1716         This routing configuration will likely still update the
1717 receive/transmit times in the driver (needed by the ARP monitor), but
1718 may bypass the bonding driver (because outgoing traffic to, in this
1719 case, another host on network 10 would use eth0 or eth1 before bond0).
1720
1721         The ARP monitor (and ARP itself) may become confused by this
1722 configuration, because ARP requests (generated by the ARP monitor)
1723 will be sent on one interface (bond0), but the corresponding reply
1724 will arrive on a different interface (eth0).  This reply looks to ARP
1725 as an unsolicited ARP reply (because ARP matches replies on an
1726 interface basis), and is discarded.  The MII monitor is not affected
1727 by the state of the routing table.
1728
1729         The solution here is simply to insure that slaves do not have
1730 routes of their own, and if for some reason they must, those routes do
1731 not supersede routes of their master.  This should generally be the
1732 case, but unusual configurations or errant manual or automatic static
1733 route additions may cause trouble.
1734
1735 8.2 Ethernet Device Renaming
1736 ----------------------------
1737
1738         On systems with network configuration scripts that do not
1739 associate physical devices directly with network interface names (so
1740 that the same physical device always has the same "ethX" name), it may
1741 be necessary to add some special logic to either /etc/modules.conf or
1742 /etc/modprobe.conf (depending upon which is installed on the system).
1743
1744         For example, given a modules.conf containing the following:
1745
1746 alias bond0 bonding
1747 options bond0 mode=some-mode miimon=50
1748 alias eth0 tg3
1749 alias eth1 tg3
1750 alias eth2 e1000
1751 alias eth3 e1000
1752
1753         If neither eth0 and eth1 are slaves to bond0, then when the
1754 bond0 interface comes up, the devices may end up reordered.  This
1755 happens because bonding is loaded first, then its slave device's
1756 drivers are loaded next.  Since no other drivers have been loaded,
1757 when the e1000 driver loads, it will receive eth0 and eth1 for its
1758 devices, but the bonding configuration tries to enslave eth2 and eth3
1759 (which may later be assigned to the tg3 devices).
1760
1761         Adding the following:
1762
1763 add above bonding e1000 tg3
1764
1765         causes modprobe to load e1000 then tg3, in that order, when
1766 bonding is loaded.  This command is fully documented in the
1767 modules.conf manual page.
1768
1769         On systems utilizing modprobe.conf (or modprobe.conf.local),
1770 an equivalent problem can occur.  In this case, the following can be
1771 added to modprobe.conf (or modprobe.conf.local, as appropriate), as
1772 follows (all on one line; it has been split here for clarity):
1773
1774 install bonding /sbin/modprobe tg3; /sbin/modprobe e1000;
1775         /sbin/modprobe --ignore-install bonding
1776
1777         This will, when loading the bonding module, rather than
1778 performing the normal action, instead execute the provided command.
1779 This command loads the device drivers in the order needed, then calls
1780 modprobe with --ignore-install to cause the normal action to then take
1781 place.  Full documentation on this can be found in the modprobe.conf
1782 and modprobe manual pages.
1783
1784 8.3. Painfully Slow Or No Failed Link Detection By Miimon
1785 ---------------------------------------------------------
1786
1787         By default, bonding enables the use_carrier option, which
1788 instructs bonding to trust the driver to maintain carrier state.
1789
1790         As discussed in the options section, above, some drivers do
1791 not support the netif_carrier_on/_off link state tracking system.
1792 With use_carrier enabled, bonding will always see these links as up,
1793 regardless of their actual state.
1794
1795         Additionally, other drivers do support netif_carrier, but do
1796 not maintain it in real time, e.g., only polling the link state at
1797 some fixed interval.  In this case, miimon will detect failures, but
1798 only after some long period of time has expired.  If it appears that
1799 miimon is very slow in detecting link failures, try specifying
1800 use_carrier=0 to see if that improves the failure detection time.  If
1801 it does, then it may be that the driver checks the carrier state at a
1802 fixed interval, but does not cache the MII register values (so the
1803 use_carrier=0 method of querying the registers directly works).  If
1804 use_carrier=0 does not improve the failover, then the driver may cache
1805 the registers, or the problem may be elsewhere.
1806
1807         Also, remember that miimon only checks for the device's
1808 carrier state.  It has no way to determine the state of devices on or
1809 beyond other ports of a switch, or if a switch is refusing to pass
1810 traffic while still maintaining carrier on.
1811
1812 9. SNMP agents
1813 ===============
1814
1815         If running SNMP agents, the bonding driver should be loaded
1816 before any network drivers participating in a bond.  This requirement
1817 is due to the interface index (ipAdEntIfIndex) being associated to
1818 the first interface found with a given IP address.  That is, there is
1819 only one ipAdEntIfIndex for each IP address.  For example, if eth0 and
1820 eth1 are slaves of bond0 and the driver for eth0 is loaded before the
1821 bonding driver, the interface for the IP address will be associated
1822 with the eth0 interface.  This configuration is shown below, the IP
1823 address 192.168.1.1 has an interface index of 2 which indexes to eth0
1824 in the ifDescr table (ifDescr.2).
1825
1826      interfaces.ifTable.ifEntry.ifDescr.1 = lo
1827      interfaces.ifTable.ifEntry.ifDescr.2 = eth0
1828      interfaces.ifTable.ifEntry.ifDescr.3 = eth1
1829      interfaces.ifTable.ifEntry.ifDescr.4 = eth2
1830      interfaces.ifTable.ifEntry.ifDescr.5 = eth3
1831      interfaces.ifTable.ifEntry.ifDescr.6 = bond0
1832      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.10.10.10 = 5
1833      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.192.168.1.1 = 2
1834      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.74.20.94 = 4
1835      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.127.0.0.1 = 1
1836
1837         This problem is avoided by loading the bonding driver before
1838 any network drivers participating in a bond.  Below is an example of
1839 loading the bonding driver first, the IP address 192.168.1.1 is
1840 correctly associated with ifDescr.2.
1841
1842      interfaces.ifTable.ifEntry.ifDescr.1 = lo
1843      interfaces.ifTable.ifEntry.ifDescr.2 = bond0
1844      interfaces.ifTable.ifEntry.ifDescr.3 = eth0
1845      interfaces.ifTable.ifEntry.ifDescr.4 = eth1
1846      interfaces.ifTable.ifEntry.ifDescr.5 = eth2
1847      interfaces.ifTable.ifEntry.ifDescr.6 = eth3
1848      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.10.10.10 = 6
1849      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.192.168.1.1 = 2
1850      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.10.74.20.94 = 5
1851      ip.ipAddrTable.ipAddrEntry.ipAdEntIfIndex.127.0.0.1 = 1
1852
1853         While some distributions may not report the interface name in
1854 ifDescr, the association between the IP address and IfIndex remains
1855 and SNMP functions such as Interface_Scan_Next will report that
1856 association.
1857
1858 10. Promiscuous mode
1859 ====================
1860
1861         When running network monitoring tools, e.g., tcpdump, it is
1862 common to enable promiscuous mode on the device, so that all traffic
1863 is seen (instead of seeing only traffic destined for the local host).
1864 The bonding driver handles promiscuous mode changes to the bonding
1865 master device (e.g., bond0), and propagates the setting to the slave
1866 devices.
1867
1868         For the balance-rr, balance-xor, broadcast, and 802.3ad modes,
1869 the promiscuous mode setting is propagated to all slaves.
1870
1871         For the active-backup, balance-tlb and balance-alb modes, the
1872 promiscuous mode setting is propagated only to the active slave.
1873
1874         For balance-tlb mode, the active slave is the slave currently
1875 receiving inbound traffic.
1876
1877         For balance-alb mode, the active slave is the slave used as a
1878 "primary."  This slave is used for mode-specific control traffic, for
1879 sending to peers that are unassigned or if the load is unbalanced.
1880
1881         For the active-backup, balance-tlb and balance-alb modes, when
1882 the active slave changes (e.g., due to a link failure), the
1883 promiscuous setting will be propagated to the new active slave.
1884
1885 11. Configuring Bonding for High Availability
1886 =============================================
1887
1888         High Availability refers to configurations that provide
1889 maximum network availability by having redundant or backup devices,
1890 links or switches between the host and the rest of the world.  The
1891 goal is to provide the maximum availability of network connectivity
1892 (i.e., the network always works), even though other configurations
1893 could provide higher throughput.
1894
1895 11.1 High Availability in a Single Switch Topology
1896 --------------------------------------------------
1897
1898         If two hosts (or a host and a single switch) are directly
1899 connected via multiple physical links, then there is no availability
1900 penalty to optimizing for maximum bandwidth.  In this case, there is
1901 only one switch (or peer), so if it fails, there is no alternative
1902 access to fail over to.  Additionally, the bonding load balance modes
1903 support link monitoring of their members, so if individual links fail,
1904 the load will be rebalanced across the remaining devices.
1905
1906         See Section 13, "Configuring Bonding for Maximum Throughput"
1907 for information on configuring bonding with one peer device.
1908
1909 11.2 High Availability in a Multiple Switch Topology
1910 ----------------------------------------------------
1911
1912         With multiple switches, the configuration of bonding and the
1913 network changes dramatically.  In multiple switch topologies, there is
1914 a trade off between network availability and usable bandwidth.
1915
1916         Below is a sample network, configured to maximize the
1917 availability of the network:
1918
1919                 |                                     |
1920                 |port3                           port3|
1921           +-----+----+                          +-----+----+
1922           |          |port2       ISL      port2|          |
1923           | switch A +--------------------------+ switch B |
1924           |          |                          |          |
1925           +-----+----+                          +-----++---+
1926                 |port1                           port1|
1927                 |             +-------+               |
1928                 +-------------+ host1 +---------------+
1929                          eth0 +-------+ eth1
1930
1931         In this configuration, there is a link between the two
1932 switches (ISL, or inter switch link), and multiple ports connecting to
1933 the outside world ("port3" on each switch).  There is no technical
1934 reason that this could not be extended to a third switch.
1935
1936 11.2.1 HA Bonding Mode Selection for Multiple Switch Topology
1937 -------------------------------------------------------------
1938
1939         In a topology such as the example above, the active-backup and
1940 broadcast modes are the only useful bonding modes when optimizing for
1941 availability; the other modes require all links to terminate on the
1942 same peer for them to behave rationally.
1943
1944 active-backup: This is generally the preferred mode, particularly if
1945         the switches have an ISL and play together well.  If the
1946         network configuration is such that one switch is specifically
1947         a backup switch (e.g., has lower capacity, higher cost, etc),
1948         then the primary option can be used to insure that the
1949         preferred link is always used when it is available.
1950
1951 broadcast: This mode is really a special purpose mode, and is suitable
1952         only for very specific needs.  For example, if the two
1953         switches are not connected (no ISL), and the networks beyond
1954         them are totally independent.  In this case, if it is
1955         necessary for some specific one-way traffic to reach both
1956         independent networks, then the broadcast mode may be suitable.
1957
1958 11.2.2 HA Link Monitoring Selection for Multiple Switch Topology
1959 ----------------------------------------------------------------
1960
1961         The choice of link monitoring ultimately depends upon your
1962 switch.  If the switch can reliably fail ports in response to other
1963 failures, then either the MII or ARP monitors should work.  For
1964 example, in the above example, if the "port3" link fails at the remote
1965 end, the MII monitor has no direct means to detect this.  The ARP
1966 monitor could be configured with a target at the remote end of port3,
1967 thus detecting that failure without switch support.
1968
1969         In general, however, in a multiple switch topology, the ARP
1970 monitor can provide a higher level of reliability in detecting end to
1971 end connectivity failures (which may be caused by the failure of any
1972 individual component to pass traffic for any reason).  Additionally,
1973 the ARP monitor should be configured with multiple targets (at least
1974 one for each switch in the network).  This will insure that,
1975 regardless of which switch is active, the ARP monitor has a suitable
1976 target to query.
1977
1978         Note, also, that of late many switches now support a functionality
1979 generally referred to as "trunk failover."  This is a feature of the
1980 switch that causes the link state of a particular switch port to be set
1981 down (or up) when the state of another switch port goes down (or up).
1982 Its purpose is to propagate link failures from logically "exterior" ports
1983 to the logically "interior" ports that bonding is able to monitor via
1984 miimon.  Availability and configuration for trunk failover varies by
1985 switch, but this can be a viable alternative to the ARP monitor when using
1986 suitable switches.
1987
1988 12. Configuring Bonding for Maximum Throughput
1989 ==============================================
1990
1991 12.1 Maximizing Throughput in a Single Switch Topology
1992 ------------------------------------------------------
1993
1994         In a single switch configuration, the best method to maximize
1995 throughput depends upon the application and network environment.  The
1996 various load balancing modes each have strengths and weaknesses in
1997 different environments, as detailed below.
1998
1999         For this discussion, we will break down the topologies into
2000 two categories.  Depending upon the destination of most traffic, we
2001 categorize them into either "gatewayed" or "local" configurations.
2002
2003         In a gatewayed configuration, the "switch" is acting primarily
2004 as a router, and the majority of traffic passes through this router to
2005 other networks.  An example would be the following:
2006
2007
2008      +----------+                     +----------+
2009      |          |eth0            port1|          | to other networks
2010      | Host A   +---------------------+ router   +------------------->
2011      |          +---------------------+          | Hosts B and C are out
2012      |          |eth1            port2|          | here somewhere
2013      +----------+                     +----------+
2014
2015         The router may be a dedicated router device, or another host
2016 acting as a gateway.  For our discussion, the important point is that
2017 the majority of traffic from Host A will pass through the router to
2018 some other network before reaching its final destination.
2019
2020         In a gatewayed network configuration, although Host A may
2021 communicate with many other systems, all of its traffic will be sent
2022 and received via one other peer on the local network, the router.
2023
2024         Note that the case of two systems connected directly via
2025 multiple physical links is, for purposes of configuring bonding, the
2026 same as a gatewayed configuration.  In that case, it happens that all
2027 traffic is destined for the "gateway" itself, not some other network
2028 beyond the gateway.
2029
2030         In a local configuration, the "switch" is acting primarily as
2031 a switch, and the majority of traffic passes through this switch to
2032 reach other stations on the same network.  An example would be the
2033 following:
2034
2035     +----------+            +----------+       +--------+
2036     |          |eth0   port1|          +-------+ Host B |
2037     |  Host A  +------------+  switch  |port3  +--------+
2038     |          +------------+          |                  +--------+
2039     |          |eth1   port2|          +------------------+ Host C |
2040     +----------+            +----------+port4             +--------+
2041
2042
2043         Again, the switch may be a dedicated switch device, or another
2044 host acting as a gateway.  For our discussion, the important point is
2045 that the majority of traffic from Host A is destined for other hosts
2046 on the same local network (Hosts B and C in the above example).
2047
2048         In summary, in a gatewayed configuration, traffic to and from
2049 the bonded device will be to the same MAC level peer on the network
2050 (the gateway itself, i.e., the router), regardless of its final
2051 destination.  In a local configuration, traffic flows directly to and
2052 from the final destinations, thus, each destination (Host B, Host C)
2053 will be addressed directly by their individual MAC addresses.
2054
2055         This distinction between a gatewayed and a local network
2056 configuration is important because many of the load balancing modes
2057 available use the MAC addresses of the local network source and
2058 destination to make load balancing decisions.  The behavior of each
2059 mode is described below.
2060
2061
2062 12.1.1 MT Bonding Mode Selection for Single Switch Topology
2063 -----------------------------------------------------------
2064
2065         This configuration is the easiest to set up and to understand,
2066 although you will have to decide which bonding mode best suits your
2067 needs.  The trade offs for each mode are detailed below:
2068
2069 balance-rr: This mode is the only mode that will permit a single
2070         TCP/IP connection to stripe traffic across multiple
2071         interfaces. It is therefore the only mode that will allow a
2072         single TCP/IP stream to utilize more than one interface's
2073         worth of throughput.  This comes at a cost, however: the
2074         striping generally results in peer systems receiving packets out
2075         of order, causing TCP/IP's congestion control system to kick
2076         in, often by retransmitting segments.
2077
2078         It is possible to adjust TCP/IP's congestion limits by
2079         altering the net.ipv4.tcp_reordering sysctl parameter.  The
2080         usual default value is 3, and the maximum useful value is 127.
2081         For a four interface balance-rr bond, expect that a single
2082         TCP/IP stream will utilize no more than approximately 2.3
2083         interface's worth of throughput, even after adjusting
2084         tcp_reordering.
2085
2086         Note that the fraction of packets that will be delivered out of
2087         order is highly variable, and is unlikely to be zero.  The level
2088         of reordering depends upon a variety of factors, including the
2089         networking interfaces, the switch, and the topology of the
2090         configuration.  Speaking in general terms, higher speed network
2091         cards produce more reordering (due to factors such as packet
2092         coalescing), and a "many to many" topology will reorder at a
2093         higher rate than a "many slow to one fast" configuration.
2094
2095         Many switches do not support any modes that stripe traffic
2096         (instead choosing a port based upon IP or MAC level addresses);
2097         for those devices, traffic for a particular connection flowing
2098         through the switch to a balance-rr bond will not utilize greater
2099         than one interface's worth of bandwidth.
2100
2101         If you are utilizing protocols other than TCP/IP, UDP for
2102         example, and your application can tolerate out of order
2103         delivery, then this mode can allow for single stream datagram
2104         performance that scales near linearly as interfaces are added
2105         to the bond.
2106
2107         This mode requires the switch to have the appropriate ports
2108         configured for "etherchannel" or "trunking."
2109
2110 active-backup: There is not much advantage in this network topology to
2111         the active-backup mode, as the inactive backup devices are all
2112         connected to the same peer as the primary.  In this case, a
2113         load balancing mode (with link monitoring) will provide the
2114         same level of network availability, but with increased
2115         available bandwidth.  On the plus side, active-backup mode
2116         does not require any configuration of the switch, so it may
2117         have value if the hardware available does not support any of
2118         the load balance modes.
2119
2120 balance-xor: This mode will limit traffic such that packets destined
2121         for specific peers will always be sent over the same
2122         interface.  Since the destination is determined by the MAC
2123         addresses involved, this mode works best in a "local" network
2124         configuration (as described above), with destinations all on
2125         the same local network.  This mode is likely to be suboptimal
2126         if all your traffic is passed through a single router (i.e., a
2127         "gatewayed" network configuration, as described above).
2128
2129         As with balance-rr, the switch ports need to be configured for
2130         "etherchannel" or "trunking."
2131
2132 broadcast: Like active-backup, there is not much advantage to this
2133         mode in this type of network topology.
2134
2135 802.3ad: This mode can be a good choice for this type of network
2136         topology.  The 802.3ad mode is an IEEE standard, so all peers
2137         that implement 802.3ad should interoperate well.  The 802.3ad
2138         protocol includes automatic configuration of the aggregates,
2139         so minimal manual configuration of the switch is needed
2140         (typically only to designate that some set of devices is
2141         available for 802.3ad).  The 802.3ad standard also mandates
2142         that frames be delivered in order (within certain limits), so
2143         in general single connections will not see misordering of
2144         packets.  The 802.3ad mode does have some drawbacks: the
2145         standard mandates that all devices in the aggregate operate at
2146         the same speed and duplex.  Also, as with all bonding load
2147         balance modes other than balance-rr, no single connection will
2148         be able to utilize more than a single interface's worth of
2149         bandwidth.  
2150
2151         Additionally, the linux bonding 802.3ad implementation
2152         distributes traffic by peer (using an XOR of MAC addresses),
2153         so in a "gatewayed" configuration, all outgoing traffic will
2154         generally use the same device.  Incoming traffic may also end
2155         up on a single device, but that is dependent upon the
2156         balancing policy of the peer's 8023.ad implementation.  In a
2157         "local" configuration, traffic will be distributed across the
2158         devices in the bond.
2159
2160         Finally, the 802.3ad mode mandates the use of the MII monitor,
2161         therefore, the ARP monitor is not available in this mode.
2162
2163 balance-tlb: The balance-tlb mode balances outgoing traffic by peer.
2164         Since the balancing is done according to MAC address, in a
2165         "gatewayed" configuration (as described above), this mode will
2166         send all traffic across a single device.  However, in a
2167         "local" network configuration, this mode balances multiple
2168         local network peers across devices in a vaguely intelligent
2169         manner (not a simple XOR as in balance-xor or 802.3ad mode),
2170         so that mathematically unlucky MAC addresses (i.e., ones that
2171         XOR to the same value) will not all "bunch up" on a single
2172         interface.
2173
2174         Unlike 802.3ad, interfaces may be of differing speeds, and no
2175         special switch configuration is required.  On the down side,
2176         in this mode all incoming traffic arrives over a single
2177         interface, this mode requires certain ethtool support in the
2178         network device driver of the slave interfaces, and the ARP
2179         monitor is not available.
2180
2181 balance-alb: This mode is everything that balance-tlb is, and more.
2182         It has all of the features (and restrictions) of balance-tlb,
2183         and will also balance incoming traffic from local network
2184         peers (as described in the Bonding Module Options section,
2185         above).
2186
2187         The only additional down side to this mode is that the network
2188         device driver must support changing the hardware address while
2189         the device is open.
2190
2191 12.1.2 MT Link Monitoring for Single Switch Topology
2192 ----------------------------------------------------
2193
2194         The choice of link monitoring may largely depend upon which
2195 mode you choose to use.  The more advanced load balancing modes do not
2196 support the use of the ARP monitor, and are thus restricted to using
2197 the MII monitor (which does not provide as high a level of end to end
2198 assurance as the ARP monitor).
2199
2200 12.2 Maximum Throughput in a Multiple Switch Topology
2201 -----------------------------------------------------
2202
2203         Multiple switches may be utilized to optimize for throughput
2204 when they are configured in parallel as part of an isolated network
2205 between two or more systems, for example:
2206
2207                        +-----------+
2208                        |  Host A   | 
2209                        +-+---+---+-+
2210                          |   |   |
2211                 +--------+   |   +---------+
2212                 |            |             |
2213          +------+---+  +-----+----+  +-----+----+
2214          | Switch A |  | Switch B |  | Switch C |
2215          +------+---+  +-----+----+  +-----+----+
2216                 |            |             |
2217                 +--------+   |   +---------+
2218                          |   |   |
2219                        +-+---+---+-+
2220                        |  Host B   | 
2221                        +-----------+
2222
2223         In this configuration, the switches are isolated from one
2224 another.  One reason to employ a topology such as this is for an
2225 isolated network with many hosts (a cluster configured for high
2226 performance, for example), using multiple smaller switches can be more
2227 cost effective than a single larger switch, e.g., on a network with 24
2228 hosts, three 24 port switches can be significantly less expensive than
2229 a single 72 port switch.
2230
2231         If access beyond the network is required, an individual host
2232 can be equipped with an additional network device connected to an
2233 external network; this host then additionally acts as a gateway.
2234
2235 12.2.1 MT Bonding Mode Selection for Multiple Switch Topology
2236 -------------------------------------------------------------
2237
2238         In actual practice, the bonding mode typically employed in
2239 configurations of this type is balance-rr.  Historically, in this
2240 network configuration, the usual caveats about out of order packet
2241 delivery are mitigated by the use of network adapters that do not do
2242 any kind of packet coalescing (via the use of NAPI, or because the
2243 device itself does not generate interrupts until some number of
2244 packets has arrived).  When employed in this fashion, the balance-rr
2245 mode allows individual connections between two hosts to effectively
2246 utilize greater than one interface's bandwidth.
2247
2248 12.2.2 MT Link Monitoring for Multiple Switch Topology
2249 ------------------------------------------------------
2250
2251         Again, in actual practice, the MII monitor is most often used
2252 in this configuration, as performance is given preference over
2253 availability.  The ARP monitor will function in this topology, but its
2254 advantages over the MII monitor are mitigated by the volume of probes
2255 needed as the number of systems involved grows (remember that each
2256 host in the network is configured with bonding).
2257
2258 13. Switch Behavior Issues
2259 ==========================
2260
2261 13.1 Link Establishment and Failover Delays
2262 -------------------------------------------
2263
2264         Some switches exhibit undesirable behavior with regard to the
2265 timing of link up and down reporting by the switch.
2266
2267         First, when a link comes up, some switches may indicate that
2268 the link is up (carrier available), but not pass traffic over the
2269 interface for some period of time.  This delay is typically due to
2270 some type of autonegotiation or routing protocol, but may also occur
2271 during switch initialization (e.g., during recovery after a switch
2272 failure).  If you find this to be a problem, specify an appropriate
2273 value to the updelay bonding module option to delay the use of the
2274 relevant interface(s).
2275
2276         Second, some switches may "bounce" the link state one or more
2277 times while a link is changing state.  This occurs most commonly while
2278 the switch is initializing.  Again, an appropriate updelay value may
2279 help.
2280
2281         Note that when a bonding interface has no active links, the
2282 driver will immediately reuse the first link that goes up, even if the
2283 updelay parameter has been specified (the updelay is ignored in this
2284 case).  If there are slave interfaces waiting for the updelay timeout
2285 to expire, the interface that first went into that state will be
2286 immediately reused.  This reduces down time of the network if the
2287 value of updelay has been overestimated, and since this occurs only in
2288 cases with no connectivity, there is no additional penalty for
2289 ignoring the updelay.
2290
2291         In addition to the concerns about switch timings, if your
2292 switches take a long time to go into backup mode, it may be desirable
2293 to not activate a backup interface immediately after a link goes down.
2294 Failover may be delayed via the downdelay bonding module option.
2295
2296 13.2 Duplicated Incoming Packets
2297 --------------------------------
2298
2299         NOTE: Starting with version 3.0.2, the bonding driver has logic to
2300 suppress duplicate packets, which should largely eliminate this problem.
2301 The following description is kept for reference.
2302
2303         It is not uncommon to observe a short burst of duplicated
2304 traffic when the bonding device is first used, or after it has been
2305 idle for some period of time.  This is most easily observed by issuing
2306 a "ping" to some other host on the network, and noticing that the
2307 output from ping flags duplicates (typically one per slave).
2308
2309         For example, on a bond in active-backup mode with five slaves
2310 all connected to one switch, the output may appear as follows:
2311
2312 # ping -n 10.0.4.2
2313 PING 10.0.4.2 (10.0.4.2) from 10.0.3.10 : 56(84) bytes of data.
2314 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.7 ms
2315 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
2316 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
2317 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
2318 64 bytes from 10.0.4.2: icmp_seq=1 ttl=64 time=13.8 ms (DUP!)
2319 64 bytes from 10.0.4.2: icmp_seq=2 ttl=64 time=0.216 ms
2320 64 bytes from 10.0.4.2: icmp_seq=3 ttl=64 time=0.267 ms
2321 64 bytes from 10.0.4.2: icmp_seq=4 ttl=64 time=0.222 ms
2322
2323         This is not due to an error in the bonding driver, rather, it
2324 is a side effect of how many switches update their MAC forwarding
2325 tables.  Initially, the switch does not associate the MAC address in
2326 the packet with a particular switch port, and so it may send the
2327 traffic to all ports until its MAC forwarding table is updated.  Since
2328 the interfaces attached to the bond may occupy multiple ports on a
2329 single switch, when the switch (temporarily) floods the traffic to all
2330 ports, the bond device receives multiple copies of the same packet
2331 (one per slave device).
2332
2333         The duplicated packet behavior is switch dependent, some
2334 switches exhibit this, and some do not.  On switches that display this
2335 behavior, it can be induced by clearing the MAC forwarding table (on
2336 most Cisco switches, the privileged command "clear mac address-table
2337 dynamic" will accomplish this).
2338
2339 14. Hardware Specific Considerations
2340 ====================================
2341
2342         This section contains additional information for configuring
2343 bonding on specific hardware platforms, or for interfacing bonding
2344 with particular switches or other devices.
2345
2346 14.1 IBM BladeCenter
2347 --------------------
2348
2349         This applies to the JS20 and similar systems.
2350
2351         On the JS20 blades, the bonding driver supports only
2352 balance-rr, active-backup, balance-tlb and balance-alb modes.  This is
2353 largely due to the network topology inside the BladeCenter, detailed
2354 below.
2355
2356 JS20 network adapter information
2357 --------------------------------
2358
2359         All JS20s come with two Broadcom Gigabit Ethernet ports
2360 integrated on the planar (that's "motherboard" in IBM-speak).  In the
2361 BladeCenter chassis, the eth0 port of all JS20 blades is hard wired to
2362 I/O Module #1; similarly, all eth1 ports are wired to I/O Module #2.
2363 An add-on Broadcom daughter card can be installed on a JS20 to provide
2364 two more Gigabit Ethernet ports.  These ports, eth2 and eth3, are
2365 wired to I/O Modules 3 and 4, respectively.
2366
2367         Each I/O Module may contain either a switch or a passthrough
2368 module (which allows ports to be directly connected to an external
2369 switch).  Some bonding modes require a specific BladeCenter internal
2370 network topology in order to function; these are detailed below.
2371
2372         Additional BladeCenter-specific networking information can be
2373 found in two IBM Redbooks (www.ibm.com/redbooks):
2374
2375 "IBM eServer BladeCenter Networking Options"
2376 "IBM eServer BladeCenter Layer 2-7 Network Switching"
2377
2378 BladeCenter networking configuration
2379 ------------------------------------
2380
2381         Because a BladeCenter can be configured in a very large number
2382 of ways, this discussion will be confined to describing basic
2383 configurations.
2384
2385         Normally, Ethernet Switch Modules (ESMs) are used in I/O
2386 modules 1 and 2.  In this configuration, the eth0 and eth1 ports of a
2387 JS20 will be connected to different internal switches (in the
2388 respective I/O modules).
2389
2390         A passthrough module (OPM or CPM, optical or copper,
2391 passthrough module) connects the I/O module directly to an external
2392 switch.  By using PMs in I/O module #1 and #2, the eth0 and eth1
2393 interfaces of a JS20 can be redirected to the outside world and
2394 connected to a common external switch.
2395
2396         Depending upon the mix of ESMs and PMs, the network will
2397 appear to bonding as either a single switch topology (all PMs) or as a
2398 multiple switch topology (one or more ESMs, zero or more PMs).  It is
2399 also possible to connect ESMs together, resulting in a configuration
2400 much like the example in "High Availability in a Multiple Switch
2401 Topology," above.
2402
2403 Requirements for specific modes
2404 -------------------------------
2405
2406         The balance-rr mode requires the use of passthrough modules
2407 for devices in the bond, all connected to an common external switch.
2408 That switch must be configured for "etherchannel" or "trunking" on the
2409 appropriate ports, as is usual for balance-rr.
2410
2411         The balance-alb and balance-tlb modes will function with
2412 either switch modules or passthrough modules (or a mix).  The only
2413 specific requirement for these modes is that all network interfaces
2414 must be able to reach all destinations for traffic sent over the
2415 bonding device (i.e., the network must converge at some point outside
2416 the BladeCenter).
2417
2418         The active-backup mode has no additional requirements.
2419
2420 Link monitoring issues
2421 ----------------------
2422
2423         When an Ethernet Switch Module is in place, only the ARP
2424 monitor will reliably detect link loss to an external switch.  This is
2425 nothing unusual, but examination of the BladeCenter cabinet would
2426 suggest that the "external" network ports are the ethernet ports for
2427 the system, when it fact there is a switch between these "external"
2428 ports and the devices on the JS20 system itself.  The MII monitor is
2429 only able to detect link failures between the ESM and the JS20 system.
2430
2431         When a passthrough module is in place, the MII monitor does
2432 detect failures to the "external" port, which is then directly
2433 connected to the JS20 system.
2434
2435 Other concerns
2436 --------------
2437
2438         The Serial Over LAN (SoL) link is established over the primary
2439 ethernet (eth0) only, therefore, any loss of link to eth0 will result
2440 in losing your SoL connection.  It will not fail over with other
2441 network traffic, as the SoL system is beyond the control of the
2442 bonding driver.
2443
2444         It may be desirable to disable spanning tree on the switch
2445 (either the internal Ethernet Switch Module, or an external switch) to
2446 avoid fail-over delay issues when using bonding.
2447
2448         
2449 15. Frequently Asked Questions
2450 ==============================
2451
2452 1.  Is it SMP safe?
2453
2454         Yes. The old 2.0.xx channel bonding patch was not SMP safe.
2455 The new driver was designed to be SMP safe from the start.
2456
2457 2.  What type of cards will work with it?
2458
2459         Any Ethernet type cards (you can even mix cards - a Intel
2460 EtherExpress PRO/100 and a 3com 3c905b, for example).  For most modes,
2461 devices need not be of the same speed.
2462
2463         Starting with version 3.2.1, bonding also supports Infiniband
2464 slaves in active-backup mode.
2465
2466 3.  How many bonding devices can I have?
2467
2468         There is no limit.
2469
2470 4.  How many slaves can a bonding device have?
2471
2472         This is limited only by the number of network interfaces Linux
2473 supports and/or the number of network cards you can place in your
2474 system.
2475
2476 5.  What happens when a slave link dies?
2477
2478         If link monitoring is enabled, then the failing device will be
2479 disabled.  The active-backup mode will fail over to a backup link, and
2480 other modes will ignore the failed link.  The link will continue to be
2481 monitored, and should it recover, it will rejoin the bond (in whatever
2482 manner is appropriate for the mode). See the sections on High
2483 Availability and the documentation for each mode for additional
2484 information.
2485         
2486         Link monitoring can be enabled via either the miimon or
2487 arp_interval parameters (described in the module parameters section,
2488 above).  In general, miimon monitors the carrier state as sensed by
2489 the underlying network device, and the arp monitor (arp_interval)
2490 monitors connectivity to another host on the local network.
2491
2492         If no link monitoring is configured, the bonding driver will
2493 be unable to detect link failures, and will assume that all links are
2494 always available.  This will likely result in lost packets, and a
2495 resulting degradation of performance.  The precise performance loss
2496 depends upon the bonding mode and network configuration.
2497
2498 6.  Can bonding be used for High Availability?
2499
2500         Yes.  See the section on High Availability for details.
2501
2502 7.  Which switches/systems does it work with?
2503
2504         The full answer to this depends upon the desired mode.
2505
2506         In the basic balance modes (balance-rr and balance-xor), it
2507 works with any system that supports etherchannel (also called
2508 trunking).  Most managed switches currently available have such
2509 support, and many unmanaged switches as well.
2510
2511         The advanced balance modes (balance-tlb and balance-alb) do
2512 not have special switch requirements, but do need device drivers that
2513 support specific features (described in the appropriate section under
2514 module parameters, above).
2515
2516         In 802.3ad mode, it works with systems that support IEEE
2517 802.3ad Dynamic Link Aggregation.  Most managed and many unmanaged
2518 switches currently available support 802.3ad.
2519
2520         The active-backup mode should work with any Layer-II switch.
2521
2522 8.  Where does a bonding device get its MAC address from?
2523
2524         When using slave devices that have fixed MAC addresses, or when
2525 the fail_over_mac option is enabled, the bonding device's MAC address is
2526 the MAC address of the active slave.
2527
2528         For other configurations, if not explicitly configured (with
2529 ifconfig or ip link), the MAC address of the bonding device is taken from
2530 its first slave device.  This MAC address is then passed to all following
2531 slaves and remains persistent (even if the first slave is removed) until
2532 the bonding device is brought down or reconfigured.
2533
2534         If you wish to change the MAC address, you can set it with
2535 ifconfig or ip link:
2536
2537 # ifconfig bond0 hw ether 00:11:22:33:44:55
2538
2539 # ip link set bond0 address 66:77:88:99:aa:bb
2540
2541         The MAC address can be also changed by bringing down/up the
2542 device and then changing its slaves (or their order):
2543
2544 # ifconfig bond0 down ; modprobe -r bonding
2545 # ifconfig bond0 .... up
2546 # ifenslave bond0 eth...
2547
2548         This method will automatically take the address from the next
2549 slave that is added.
2550
2551         To restore your slaves' MAC addresses, you need to detach them
2552 from the bond (`ifenslave -d bond0 eth0'). The bonding driver will
2553 then restore the MAC addresses that the slaves had before they were
2554 enslaved.
2555
2556 16. Resources and Links
2557 =======================
2558
2559         The latest version of the bonding driver can be found in the latest
2560 version of the linux kernel, found on http://kernel.org
2561
2562         The latest version of this document can be found in the latest kernel
2563 source (named Documentation/networking/bonding.txt).
2564
2565         Discussions regarding the usage of the bonding driver take place on the
2566 bonding-devel mailing list, hosted at sourceforge.net. If you have questions or
2567 problems, post them to the list.  The list address is:
2568
2569 bonding-devel@lists.sourceforge.net
2570
2571         The administrative interface (to subscribe or unsubscribe) can
2572 be found at:
2573
2574 https://lists.sourceforge.net/lists/listinfo/bonding-devel
2575
2576         Discussions regarding the developpement of the bonding driver take place
2577 on the main Linux network mailing list, hosted at vger.kernel.org. The list
2578 address is:
2579
2580 netdev@vger.kernel.org
2581
2582         The administrative interface (to subscribe or unsubscribe) can
2583 be found at:
2584
2585 http://vger.kernel.org/vger-lists.html#netdev
2586
2587 Donald Becker's Ethernet Drivers and diag programs may be found at :
2588  - http://web.archive.org/web/*/http://www.scyld.com/network/ 
2589
2590 You will also find a lot of information regarding Ethernet, NWay, MII,
2591 etc. at www.scyld.com.
2592
2593 -- END --