From 6123b0e274503a0d3588e84fbe07c9aa01bfaf5d Mon Sep 17 00:00:00 2001 From: Antonio Ospite Date: Mon, 31 Oct 2011 17:12:19 -0700 Subject: [PATCH] leds: save the delay values after a successful call to blink_set() When calling the hardware blinking function implemented by blink_set(), the delay_on and delay_off values are not preserved across calls. Fix that and make the "timer" trigger work as expected when hardware blinking is available. BEFORE the fix: $ cd /sys/class/leds/someled $ echo timer > trigger $ cat delay_on delay_off 0 0 $ echo 100 > delay_on $ cat delay_on delay_off 0 0 $ echo 100 > delay_off $ cat delay_on delay_off 0 0 AFTER the fix: $ cd /sys/class/leds/someled $ echo timer > trigger $ cat delay_on delay_off 0 0 $ echo 100 > delay_on $ cat delay_on delay_off 100 0 $ echo 100 > delay_off $ cat delay_on delay_off 100 100 Signed-off-by: Antonio Ospite Reviewed-by: Johannes Berg Cc: Richard Purdie Cc: Cc: Signed-off-by: Andrew Morton Signed-off-by: Linus Torvalds --- Reading git-format-patch failed