From 1a793a10899487d40ac3071f52a6e231260d935d Mon Sep 17 00:00:00 2001 From: Rajkumar Kasirajan Date: Wed, 30 May 2012 14:54:28 +0530 Subject: [PATCH] ab8500-fg: Use correct battery charge full design If battery is not identified while fg probe, mah_max_design gets initialized with unknown battery's charge full design. Reinitialize mah_max_design if battery is identified after fg probe. Signed-off-by: Rajkumar Kasirajan Signed-off-by: Lee Jones Reviewed-by: Vijaya Kumar K-1 Reviewed-by: Marcus COOPER Reviewed-by: Olivier CLERGEAUD Reviewed-by: Arun MURTHY Reviewed-by: Rabin VINCENT Tested-by: Rupesh KUMAR Tested-by: Jonas ABERG --- Reading git-format-patch failed