From fa466c91970a0207d9384016cc7884a7f61834b6 Mon Sep 17 00:00:00 2001 From: Franklin S Cooper Jr Date: Wed, 22 Jul 2015 07:32:22 -0500 Subject: [PATCH] spi: davinci: Choose correct pre-scaler limit based on SOC Currently the pre-scaler limit is incorrect. The value differs slightly for various devices so a single value can't be used. Using the compatible field select the correct pre-scaler limit. Add new compatible field value for Keystone devices to support their unique pre-scaler limit value. Signed-off-by: Franklin S Cooper Jr Reviewed-by: Sekhar Nori Signed-off-by: Mark Brown --- Reading git-format-patch failed