From b689fa799a1450056044a47d6afa6ad52f3a8997 Mon Sep 17 00:00:00 2001 From: Luciano Coelho Date: Wed, 20 Aug 2014 17:26:58 +0300 Subject: [PATCH] iwlwifi: mvm: reset the temperature when temperature test is disabled Since we can't read the actual temperature when the firmware is running, just set the temperature to 0 when the test is disabled and disable CT Kill if it was enabled. Additionally, since we rely on iwl_mvm_tt_handler() to exit CT kill when in test mode, call iwl_mvm_exit_ctkill() in that function if the temperature is low again. Also make the iwl_mvm_enter_ctkill() and iwl_mvm_exit_ctkill() return if called when not necessary anymore (e.g. when iwl_mvm_exit_ctkill() is called when we're not in CT-kill). Signed-off-by: Luciano Coelho Reviewed-by: Johannes Berg Signed-off-by: Emmanuel Grumbach --- Reading git-format-patch failed