From 4dcb5a0bffaa7dc51e738c4f651a31993b1eb08b Mon Sep 17 00:00:00 2001 From: Peter Ujfalusi Date: Thu, 14 Nov 2013 11:35:33 +0200 Subject: [PATCH] ASoC: davinci-mcasp: Fix synchronous master receive mode In synchronous mode both transmit and receive sections are using the TX clocks. In setup like this the TX clocks need to be enabled when capture is running. Signed-off-by: Peter Ujfalusi Signed-off-by: Mark Brown --- Reading git-format-patch failed