From 422af17c67b8ea2bcf39b6f6db7341f5b62c1b12 Mon Sep 17 00:00:00 2001 From: Benjamin Romer Date: Thu, 24 Jul 2014 14:08:42 -0400 Subject: [PATCH] staging: unisys: move installer to sysfs and split fields The installer entry in /proc/visorchipset/installer was composed of three separate fields as one entry. This patch removes the proc entry and associated functions, and creates new fields with distinct entries under sysfs in the visorchipset/install directory. The fields are: textid: used to send the ID of a string that should be displayed on s-Par's automatic installation progress screen. Setting this field when not in installation mode (boottotool was set on the previous guest boot) has no effect. remaining_steps: used to set the value of the progress bar on the s-Par automatic installation progress screen. This field has no effect if not in installation mode. error: used to send the ID of a string that should be displayed on s-Par's automatic installation progress screen when an error is encountered during installation. This field has no effect if not in installation mode. Signed-off-by: Benjamin Romer Signed-off-by: Greg Kroah-Hartman --- Reading git-format-patch failed