From 0d96ef5ff4086a4143eacb036cf28affd1db0cab Mon Sep 17 00:00:00 2001 From: Webb Scales Date: Thu, 23 Apr 2015 09:31:55 -0500 Subject: [PATCH] hpsa: clean up host, channel, target, lun prints We had a mix of formats used for specifying controller, bus, target, and lun address of devices. change to the format used by the scsi midlayer and upper layer (2:3:0:0) so you can easily follow the information from hpsa to scsi midlayer to sd upper layer. Also add this information: - product ID - vendor ID - RAID level - SSD Smath Path capable and enabled - exposure level (sg-only) Example: hpsa 0000:04:00.0: added scsi 2:0:0:0: Direct-Access HP LOGICAL VOLUME RAID-0 SSDSmartPathCap+ En+ Exp=4 scsi 2:0:0:0: Direct-Access HP LOGICAL VOLUME 10.0 PQ: 0 ANSI: 5 sd 2:0:0:0: [sdr] 12501713072 512-byte logical blocks: (6.40 TB/5.82 TiB) sd 2:0:0:0: [sdr] 4096-byte physical blocks sd 2:0:0:0: [sdr] Attached SCSI disk sd 2:0:0:0: Attached scsi generic sg20 type 0 Reviewed-by: Scott Teel Reviewed-by: Kevin Barnett Reviewed-by: Tomas Henzl Reviewed-by: Hannes Reinecke Signed-off-by: Robert Elliott Signed-off-by: Don Brace Reviewed-by: Christoph Hellwig Signed-off-by: James Bottomley --- Reading git-format-patch failed