From: Teodora Baluta Date: Mon, 29 Jun 2015 12:44:50 +0000 (+0300) Subject: iio: magnetometer: mmc35240: fix available sampling frequencies X-Git-Tag: omap-for-v4.3/fixes-merge-window~229^2~2^2~6 X-Git-Url: http://git.openpandora.org/cgi-bin/gitweb.cgi?a=commitdiff_plain;h=2616dfa1d3061b02c3cbce60bc1a59281eccae31;p=pandora-kernel.git iio: magnetometer: mmc35240: fix available sampling frequencies Fix the sampling frequencies according to the datasheet (page 8). The datasheet specifies the following available frequencies for continuous mode: 1.5 Hz, 13 Hz, 25 Hz, and 50 Hz. Also fix comments about the ODR to comply with datasheet. Signed-off-by: Teodora Baluta Signed-off-by: Jonathan Cameron --- Reading git-diff-tree failed