ixgbe: fix linking at 100Mbps on copper devices with MNG FW enabled
authorEmil Tantilov <emil.s.tantilov@intel.com>
Tue, 13 May 2014 08:24:00 +0000 (08:24 +0000)
committerJeff Kirsher <jeffrey.t.kirsher@intel.com>
Tue, 27 May 2014 06:53:09 +0000 (23:53 -0700)
Driver was calling setup_link to make sure that fiber interfaces with MNG FW
enabled will get link on probe because the laser was most likely turned off.
This prevented non-fiber devices with MNG FW from linking at 100Mbps.

This patch adds a check to only call setup_link for fiber devices.

Reported-and-by: Tony Luck <tony.luck@intel.com>
Signed-off-by: Emil Tantilov <emil.s.tantilov@intel.com>
Tested-by: Tony Luck <tony.luck@intel.com>
Tested-by: Phil Schmitt <phillip.j.schmitt@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
drivers/net/ethernet/intel/ixgbe/ixgbe_main.c