The reference clock path on newer IP FLLs requires a different
configuration, and should avoid integer mode operation. This patch adds
support for both the new encoding and updates the calculation.
Signed-off-by: Charles Keepax <ckeepax@opensource.wolfsonmicro.com> Signed-off-by: Mark Brown <broonie@linaro.org>