staging: comedi: cb_pcidas64: fix incorrect AI range code handling
authorIan Abbott <abbotti@mev.co.uk>
Mon, 19 Jan 2015 14:47:27 +0000 (14:47 +0000)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sun, 25 Jan 2015 11:59:09 +0000 (19:59 +0800)
The hardware range code values and list of valid ranges for the AI
subdevice is incorrect for several supported boards.  The hardware range
code values for all boards except PCI-DAS4020/12 is determined by
calling `ai_range_bits_6xxx()` based on the maximum voltage of the range
and whether it is bipolar or unipolar, however it only returns the
correct hardware range code for the PCI-DAS60xx boards.  For
PCI-DAS6402/16 (and /12) it returns the wrong code for the unipolar
ranges.  For PCI-DAS64/Mx/16 it returns the wrong code for all the
ranges and the comedi range table is incorrect.

Change `ai_range_bits_6xxx()` to use a look-up table pointed to by new
member `ai_range_codes` of `struct pcidas64_board` to map the comedi
range table indices to the hardware range codes.  Use a new comedi range
table for the PCI-DAS64/Mx/16 boards (and the commented out variants).

Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Cc: <stable@vger.kernel.org> # 3.18.x
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/cb_pcidas64.c