[POWERPC] PPC440EP Interrupt Triggering and Level Settings
authorWolfgang Ocker <weo@reccoware.de>
Sun, 10 Feb 2008 19:24:02 +0000 (06:24 +1100)
committerJosh Boyer <jwboyer@linux.vnet.ibm.com>
Sat, 16 Feb 2008 03:33:02 +0000 (21:33 -0600)
Corrected IRQ triggering and level settings according to latest revision
of the 440EP User Manual (rev 1.24 nov 16, 2007).

The incorrect settings might cause a failure of the network if both
onchip ethernet ports are under heavy load.

Signed-off-by: Wolfgang Ocker <weo@reccoware.de>
Acked-by: Stefan Roese <sr@denx.de>
Signed-off-by: Josh Boyer <jwboyer@linux.vnet.ibm.com>

No differences found