brcmsmac: change lcnphy receive i/q calibration routine
authorArend van Spriel <arend@broadcom.com>
Tue, 20 Aug 2013 14:00:40 +0000 (16:00 +0200)
committerJohn W. Linville <linville@tuxdriver.com>
Thu, 22 Aug 2013 18:30:33 +0000 (14:30 -0400)
The gain level control for the test tone has been changed. This
calbration test tone is used to determine the i/q compensation.
The i/q calibration routine has been reworked to accomodate this.

Cc: Jonas Gorski <jogo@openwrt.org>
Tested-by: David Herrmann <dh.herrmann@gmail.com>
Reviewed-by: Pieter-Paul Giesberts <pieterpg@broadcom.com>
Reviewed-by: Hante Meuleman <meuleman@broadcom.com>
Signed-off-by: Arend van Spriel <arend@broadcom.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>