It is possible to call clk_set_rate on a clock with a NULL parent. One
such example is an adjustable-rate root clock. Ensure that
clk_calc_new_rates does not dereference parent without checking first
and also handle the corner cases gracefully.
Reported-by: Rajendra Nayak <rnayak@ti.com> Signed-off-by: Mike Turquette <mturquette@linaro.org>