Bluetooth: Use proper timer for hci command timout
authorVille Tervo <ville.tervo@nokia.com>
Wed, 16 Feb 2011 14:32:41 +0000 (16:32 +0200)
committerGustavo F. Padovan <padovan@profusion.mobi>
Wed, 16 Feb 2011 19:33:26 +0000 (16:33 -0300)
Use proper timer instead of hci command flow control to timeout
failed hci commands. Otherwise stack ends up sending commands
when flow control is used to block new commands.

2010-09-01 18:29:41.592132 < HCI Command: Remote Name Request (0x01|0x0019) plen 10
    bdaddr 00:16:CF:E1:C7:D7 mode 2 clkoffset 0x0000
2010-09-01 18:29:41.592681 > HCI Event: Command Status (0x0f) plen 4
    Remote Name Request (0x01|0x0019) status 0x00 ncmd 0
2010-09-01 18:29:51.022033 < HCI Command: Remote Name Request Cancel (0x01|0x001a) plen 6
    bdaddr 00:16:CF:E1:C7:D7

Signed-off-by: Ville Tervo <ville.tervo@nokia.com>
Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>