ath9k: shorten the calibration interval during strong interference
authorFelix Fietkau <nbd@openwrt.org>
Mon, 2 Aug 2010 13:53:15 +0000 (15:53 +0200)
committerJohn W. Linville <linville@tuxdriver.com>
Mon, 16 Aug 2010 19:26:39 +0000 (15:26 -0400)
When the noise floor limits are being bypassed because of strong
interference, sensitivity is also reduced.
In order to recover from this as quickly as possible, trigger a
long periodic calibration every second instead of every 30 seconds,
until the NF median is within limits again. This is especially important
if the interference lasts for a while, since it takes multiple clean
NF calibrations to bring the median back to normal.

Signed-off-by: Felix Fietkau <nbd@openwrt.org>
Signed-off-by: John W. Linville <linville@tuxdriver.com>

No differences found