USB: cp210x: initialise baud rate at open
authorJohan Hovold <jhovold@gmail.com>
Sun, 15 Jan 2012 23:36:52 +0000 (00:36 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 3 Feb 2012 17:22:26 +0000 (09:22 -0800)
commit cdc32fd6f7b2b2580d7f1b74563f888e4dd9eb8a upstream.

The newer cp2104 devices require the baud rate to be initialised after
power on. Make sure it is set when port is opened.

Signed-off-by: Johan Hovold <jhovold@gmail.com>
Cc: Preston Fick <preston.fick@silabs.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

No differences found