powerpc/perf/hv-24x7: Simplify catalog_read()
authorsukadev@linux.vnet.ibm.com <sukadev@linux.vnet.ibm.com>
Wed, 1 Oct 2014 06:03:18 +0000 (23:03 -0700)
committerMichael Ellerman <mpe@ellerman.id.au>
Tue, 7 Oct 2014 05:57:10 +0000 (16:57 +1100)
catalog_read() implements the read interface for the sysfs file

/sys/bus/event_source/devices/hv_24x7/interface/catalog

It essentially takes a buffer, an offset and count as parameters
to the read() call.  It makes a hypervisor call to read a specific
page from the catalog and copy the required bytes into the given
buffer. Each call to catalog_read() returns at most one 4K page.

Given these requirements, we should be able to simplify the
catalog_read().

Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.vnet.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>