Those two properties should have been set to zero, which
is the same as not specifying them.
Having address-cells set to 1 causes OF interrupt
mapping routines to add 1 to the interrupt-cells
property and as result fail because all calculations
are off by one.
Signed-off-by: Lucas Stach <l.stach@pengutronix.de>
Signed-off-by: Shawn Guo <shawn.guo@freescale.com>