Input: tsc2007 - debounce pressure measurement
authorThierry Reding <thierry.reding@avionic-design.de>
Tue, 17 May 2011 16:29:45 +0000 (09:29 -0700)
committerDmitry Torokhov <dmitry.torokhov@gmail.com>
Tue, 17 May 2011 16:38:34 +0000 (09:38 -0700)
When the controller signals a pen-down event via the platform-specific
GPIO, while the sample values indicate an invalid measurement, the
measurement needs to be repeated.

Signed-off-by: Thierry Reding <thierry.reding@avionic-design.de>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>

No differences found