The volume levels in original implementation are incorrect and does
not match the dB scale. The real range is linear (in the sense of
the dB scale) from 0dB to -100dB. Remove logaritmic table and make
all volumes from range 0dB..100dB.
The tests are in RedHat's bugzilla #540817.
Signed-off-by: Jaroslav Kysela <perex@perex.cz>
Signed-off-by: Takashi Iwai <tiwai@suse.de>