hwmon: Add tachometer pulses per fan revolution to sysfs ABI
authorGuenter Roeck <guenter.roeck@ericsson.com>
Wed, 2 Mar 2011 23:19:35 +0000 (15:19 -0800)
committerGuenter Roeck <guenter.roeck@ericsson.com>
Tue, 15 Mar 2011 05:39:12 +0000 (22:39 -0700)
Some fan control chips support a configuration register to set the number of
tachometer pulses per fan revolution. Add an ABI attribute to support this
configuration register.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Documentation/hwmon/sysfs-interface

index c6559f1..83a6987 100644 (file)
@@ -187,6 +187,17 @@ fan[1-*]_div       Fan divisor.
                Note that this is actually an internal clock divisor, which
                affects the measurable speed range, not the read value.
 
+fan[1-*]_pulses        Number of tachometer pulses per fan revolution.
+               Integer value, typically between 1 and 4.
+               RW
+               This value is a characteristic of the fan connected to the
+               device's input, so it has to be set in accordance with the fan
+               model.
+               Should only be created if the chip has a register to configure
+               the number of pulses. In the absence of such a register (and
+               thus attribute) the value assumed by all devices is 2 pulses
+               per fan revolution.
+
 fan[1-*]_target
                Desired fan speed
                Unit: revolution/min (RPM)