Some regulators have a fixed load that isn't captured by
consumers that the kernel knows about. Add a constraint to
support this.
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
- regulator-initial-mode: initial operating mode. The set of possible operating
modes depends on the capabilities of every hardware so each device binding
documentation explains which values the regulator supports.
+- regulator-system-load: Load in uA present on regulator that is not captured by
+ any consumer request.
Deprecated properties:
- regulator-compatible: If a regulator chip contains multiple