According to the datasheet, writing to the level register has no effect
when GPIO is programmed as input. Actually the the level register is
read-only when configured as input. Thus presetting the output level
before switching to output is _NOT_ possible. Any writes are lost!
Hence we set the level after configuring the GPIO as output.
But we cannot prevent a short low pulse if direction is set to high and
an external pull-up is connected.
Signed-off-by: Daniel Krueger <daniel.krueger@systec-electronic.com>
Signed-off-by: Alexander Stein <alexander.stein@systec-electronic.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>