s390,time: revert direct ktime path for s390 clockevent device
authorMartin Schwidefsky <schwidefsky@de.ibm.com>
Fri, 22 Nov 2013 11:04:18 +0000 (12:04 +0100)
committerBen Hutchings <ben@decadent.org.uk>
Thu, 1 Jan 2015 01:27:51 +0000 (01:27 +0000)
commit 8adbf78ec4839c1dc4ff20c9a1f332a7bc99e6e6 upstream.

Git commit 4f37a68cdaf6dea833cfdded2a3e0c47c0f006da
"s390: Use direct ktime path for s390 clockevent device" makes use
of the CLOCK_EVT_FEAT_KTIME clockevent option to avoid the delta
calculation with ktime_get() in clockevents_program_event and the
get_tod_clock() in s390_next_event. This is based on the assumption
that the difference between the internal ktime and the hardware
clock is reflected in the wall_to_monotonic delta. But this is not
true, the ntp corrections are applied via changes to the tk->mult
multiplier and this is not reflected in wall_to_monotonic.

In theory this could be solved by using the raw monotonic clock
but it is simpler to switch back to the standard clock delta
calculation.

Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
[bwh: Backported to 3.2: s/get_tod_clock()/get_clock()/]
Signed-off-by: Ben Hutchings <ben@decadent.org.uk>